C2 partial transpedicular screw technique for atlantoaxial dislocation with high-riding vertebral artery: A technique note with case series

被引:8
|
作者
Guo, Qunfeng [1 ]
Zhou, Xin [1 ]
Guo, Xiang [1 ]
Han, Zhao [1 ]
Chen, Fei [1 ]
Zhu, Jingyu [1 ]
Lu, Xuhua [1 ]
Ni, Bin [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, 415 Fengyang Rd, Shanghai 200003, Peoples R China
基金
中国国家自然科学基金;
关键词
Atlantoaxial dislocation; Atlantoaxial arthrodesis; Atlantoaxial fusion; C2 pedicle screw; C2 partial transpedicular screw; PEDICLE SCREWS; C1-C2; FUSION; FIXATION; PLACEMENT; STABILITY; FORAMEN; GROOVE; PLATE;
D O I
10.1016/j.clineuro.2020.106403
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Although the C2 pedicle screw (C2PS) is currently the most biomechanically robust option for C2 fixation, the high-riding vertebral artery (HRVA) precludes safe C2PS placement. However, unintentional partial C2 pedicle perforation and vertebral foramen violation due to C2PS placement without neurovascular complications occurred frequently in clinic. Therefore, we have attempted to apply C2 partial transpedicular screw (C2PTS) in patients with HRVA with satisfactory preliminary outcomes. The aim of the present study is to introduce the C2PTS technique and report the preliminary radiological and clinical outcomes of application of C2PTS. Patients and methods: The data of 15 patients with atlantoaxial dislocation underwent atlantoaxial arthrodesis with posterior screw-rod construct were retrospectively reviewed. All patients had unilateral or bilateral HRVA that precluded safe C2PS placement and C2PTS was used as an alternative. In this technique, a Penfield dissector was used to properly mobilize the HRVA inferiorly to preclude vertebral artery injury and pave the way for C2PTS placement. The C2PTS travelled under the superior border of the isthmus and toward the ipsilateral atlantoaxial articulation. The implant position and atlantoaxial reduction were evaluated using computed tomography (CT) scans and vertebral artery (VA) was assessed using CT angiography postoperatively. Results: Satisfactory C2PTS placement and atlantoaxial reduction were achieved in all patients. Postoperatively, no vertebral artery injury and implant failure were observed, and bone fusion was achieved in all the patients. Additionally, there were no VA occlusion or stenosis due to screws demonstrated on VA CT angiography. Conclusion: C2PTS can achieve three-column fixation of axis and is an efficient alternative to C2PS which is prohibited due to HRVA; also, gently mobilizing the HRVA inferiorly is mandatory to prevent vertebral artery injury during C2PTS placement.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Ipsilateral arcuate foramen and high-riding vertebral artery: implication on C1-C2 instrumentation
    Elgafy, Hossein
    Pompo, Frank
    Vela, Ryan
    Elsamaloty, Haitham M.
    SPINE JOURNAL, 2014, 14 (07): : 1351 - 1355
  • [32] A New Entrance Technique for C2 Pedicle Screw Placement and the Use in Patients With Atlantoaxial Instability
    Liu, Jia-Ming
    Jiang, Jian
    Liu, Zhi-Li
    Long, Xin-Hua
    Chen, Wen-Zhao
    Zhou, Yang
    Gao, Song
    He, Lai-Chang
    Huang, Shan-Hu
    CLINICAL SPINE SURGERY, 2017, 30 (05): : E573 - E577
  • [33] C1-C2 pedicle screw fixation for adolescent with os odontoideum associated atlantoaxial dislocation and a compound reduction technique for irreducible atlantoaxial dislocation
    Liu, Jia
    Zhu, Ling-Jun
    Jiang, En-Ze
    Bao, Xiao-Gang
    Hu, Bo
    Niu, Dong-Yang
    Xu, Guo-Hua
    CHINESE MEDICAL JOURNAL, 2019, 132 (10) : 1253 - 1256
  • [34] Clinical Outcome Analysis of Posterior C1 and C2 Screw Rod Fixation (Harms-Goel Technique) in Traumatic Atlantoaxial Dislocation
    Singh, Deepak Kumar
    Agrahari, Vrihaspati Kumar
    Kaif, Md
    Yadav, Kuldeep
    Singh, Rakesh Kumar
    Ahmad, Farhan
    Khan, Khursheed
    Pathak, Vipul
    INDIAN JOURNAL OF NEUROTRAUMA, 2019, 16 (01): : 58 - 62
  • [35] The C2 Cortical Screw, an Alternative Fixation Technique for the C2 Segment During High Cervical Spine Surgery: Technical Note
    Kim, Gang-Un
    Lee, Gun Woo
    WORLD NEUROSURGERY, 2020, 142 : 24 - 28
  • [36] Three-dimensional reduction method with a modified C2 isthmus screw in irreducible atlantoaxial dislocation: a technical note
    Zhou, Shengyuan
    Yuan, Bo
    Liu, Weicong
    Tang, Yifan
    Chen, Xiongsheng
    Jia, Lianshun
    BMC SURGERY, 2021, 21 (01)
  • [37] Atlantoaxial intra-articular cage fusion by posterior intermuscular approach for treating reducible atlantoaxial dislocation: a technique note with case series
    Xu, Zhenji
    Wu, Ji
    Chen, Fei
    Ding, Yiyang
    Ni, Bin
    Xu, Peng
    Guo, Qunfeng
    EUROPEAN SPINE JOURNAL, 2024, 33 (08) : 3060 - 3068
  • [38] Three-dimensional reduction method with a modified C2 isthmus screw in irreducible atlantoaxial dislocation: a technical note
    Shengyuan Zhou
    Bo Yuan
    Weicong Liu
    Yifan Tang
    Xiongsheng Chen
    Lianshun Jia
    BMC Surgery, 21
  • [39] Assessment of failure risks during C2 vertebra pedicle screw insertion using three-dimensional computed tomography angiography analysis: the role of high-riding vertebral artery and narrow pedicles
    Arslan, Dilek
    Govsa, Figen
    Ozer, Mehmet Asim
    Kitis, Omer
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 47 (01)
  • [40] Modification of Wright's technique for C2 translaminar screw fixation: technical note
    Kabir, S. M. R.
    Casey, A. T. H.
    ACTA NEUROCHIRURGICA, 2009, 151 (11) : 1543 - 1547