C2 partial transpedicular screw technique for atlantoaxial dislocation with high-riding vertebral artery: A technique note with case series

被引:8
|
作者
Guo, Qunfeng [1 ]
Zhou, Xin [1 ]
Guo, Xiang [1 ]
Han, Zhao [1 ]
Chen, Fei [1 ]
Zhu, Jingyu [1 ]
Lu, Xuhua [1 ]
Ni, Bin [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, 415 Fengyang Rd, Shanghai 200003, Peoples R China
基金
中国国家自然科学基金;
关键词
Atlantoaxial dislocation; Atlantoaxial arthrodesis; Atlantoaxial fusion; C2 pedicle screw; C2 partial transpedicular screw; PEDICLE SCREWS; C1-C2; FUSION; FIXATION; PLACEMENT; STABILITY; FORAMEN; GROOVE; PLATE;
D O I
10.1016/j.clineuro.2020.106403
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Although the C2 pedicle screw (C2PS) is currently the most biomechanically robust option for C2 fixation, the high-riding vertebral artery (HRVA) precludes safe C2PS placement. However, unintentional partial C2 pedicle perforation and vertebral foramen violation due to C2PS placement without neurovascular complications occurred frequently in clinic. Therefore, we have attempted to apply C2 partial transpedicular screw (C2PTS) in patients with HRVA with satisfactory preliminary outcomes. The aim of the present study is to introduce the C2PTS technique and report the preliminary radiological and clinical outcomes of application of C2PTS. Patients and methods: The data of 15 patients with atlantoaxial dislocation underwent atlantoaxial arthrodesis with posterior screw-rod construct were retrospectively reviewed. All patients had unilateral or bilateral HRVA that precluded safe C2PS placement and C2PTS was used as an alternative. In this technique, a Penfield dissector was used to properly mobilize the HRVA inferiorly to preclude vertebral artery injury and pave the way for C2PTS placement. The C2PTS travelled under the superior border of the isthmus and toward the ipsilateral atlantoaxial articulation. The implant position and atlantoaxial reduction were evaluated using computed tomography (CT) scans and vertebral artery (VA) was assessed using CT angiography postoperatively. Results: Satisfactory C2PTS placement and atlantoaxial reduction were achieved in all patients. Postoperatively, no vertebral artery injury and implant failure were observed, and bone fusion was achieved in all the patients. Additionally, there were no VA occlusion or stenosis due to screws demonstrated on VA CT angiography. Conclusion: C2PTS can achieve three-column fixation of axis and is an efficient alternative to C2PS which is prohibited due to HRVA; also, gently mobilizing the HRVA inferiorly is mandatory to prevent vertebral artery injury during C2PTS placement.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Technique of C2 Subfacetal Screw in Patients with High-Riding Vertebral Artery
    Salunke, Pravin
    Singh, Apinderpreet
    Karthigeyan, Madhivanan
    WORLD NEUROSURGERY, 2020, 144 : 59 - 59
  • [2] The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series
    Dong-Ho Lee
    Sehan Park
    Jae Hwan Cho
    Chang Ju Hwang
    Hyung Rae Lee
    Sang Yun Seok
    Choon Sung Lee
    European Spine Journal, 2022, 31 : 1251 - 1259
  • [3] The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series
    Lee, Dong-Ho
    Park, Sehan
    Cho, Jae Hwan
    Hwang, Chang Ju
    Lee, Hyung Rae
    Seok, Sang Yun
    Lee, Choon Sung
    EUROPEAN SPINE JOURNAL, 2022, 31 (05) : 1251 - 1259
  • [4] Atlantoaxial transarticular screw fixation for a high-riding vertebral artery
    Neo, M
    Matsushita, M
    Iwashita, Y
    Yasuda, T
    Sakamoto, T
    Nakamura, T
    SPINE, 2003, 28 (07) : 666 - 670
  • [5] Clinical Outcomes of Atlantoaxial Dislocation Combined with High-Riding Vertebral Artery Using C2 Translaminar Screws
    Wang, Yongqiang
    Wang, Chao
    Yan, Ming
    WORLD NEUROSURGERY, 2019, 122 : E1511 - E1518
  • [6] C2 pedicle screw insertion assisted by mobilization of the vertebral artery in cases with high-riding vertebral artery
    Liu, Jiang
    Jia, Li
    Zeng, Minghui
    Xu, Hao
    Zhang, Rui
    Pang, Qi
    HELIYON, 2024, 10 (15)
  • [7] The New Alternative Technique Outcomes: Atlas Lateral Mass Screw and C2-3 Transfacet Screw Fixation for Complex Atlantoaxial Instability in Patients with Thin C2 Pedicle or High-Riding Vertebral Artery
    Cine, Hidayet Safak
    Avci, Idris
    Uysal, Ece
    Unsal, Ulkun Unlu
    Gunaydin, Mehmet Emre
    Paksoy, Kemal
    Senturk, Salim
    Yaman, Onur
    WORLD NEUROSURGERY, 2024, 191 : E246 - E255
  • [8] Different C2 screw placement techniques with mobilization of the vertebral artery in high-riding vertebral artery cases: Cadaver dissection
    Harman, Ferhat
    Oglin, Volkan
    Yilmaz, Mehmet Ozgur
    Orhun, Omer
    Baran, Oguz
    Boyukyilmaz, Seyma
    Gezercan, Yurdal
    Dalbayrak, Sedat
    Dagcinar, Adnan
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2023, 14 (04): : 341 - 345
  • [9] Prevalence of High-Riding Vertebral Artery and Morphometry of C2 Pedicles Using a Novel Computed Tomography Reconstruction Technique
    Wajanavisit, Wiwat
    Lertudomphonwanit, Thamrong
    Fuangfa, Praman
    Chanplakorn, Pongsthorn
    Kraiwattanapong, Chaiwat
    Jaovisidha, Supaneewan
    ASIAN SPINE JOURNAL, 2016, 10 (06) : 1141 - 1148
  • [10] Operative management for atlantoaxial instability in case of bilateral high-riding vertebral artery
    Daentzer, Dorothea
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (02) : 177 - 182