DOSIMETRIC EVALUATION OF DENTAL IMPLANT PLANNING EXAMINATIONS WITH CONE-BEAM COMPUTED TOMOGRAPHY

被引:4
|
作者
Andrade, Marcos E. A. [1 ]
Khoury, Helen J. [1 ]
Nascimento Neto, Joao B. S. [2 ]
Kramer, Richard [1 ]
机构
[1] Univ Fed Pernambuco DEN UFPE, Dept Nucl Engn, BR-50740540 Recife, PE, Brazil
[2] Univ Pernambuco FOP UPE, Fac Odontol Pernambuco, BR-54753020 Camaragibe, PE, Brazil
关键词
CT; DEVICES;
D O I
10.1093/rpd/nct211
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this work was to perform a dosimetric evaluation of two cone-beam computed tomography scanners. The study was performed with two scanners: i-CAT classic and PreXion 3D. Air kerma-area product (P-KA) was measured for all full-arch dental implant planning protocols. Surface air kerma was also estimated at the region of the eyes, salivary glands and thyroid using thermoluminescence dosemeters positioned on an anthropomorphic phantom. The P-KA values for the i-CAT classic ranged from 24 to 180 mu Gy m(2) and, for the PreXion, from 70 to 138 mu Gy m(2). The large variation of these values was mainly caused by acquisition time and field of views. The surface air kerma values were from 0.08 to 3.39 mGy at the eyes, 0.50 to 3.96 mGy at the parotids, 0.11 to 2.95 mGy at the submandibular glands and 0.05 to 1.32 mGy at the thyroid. These values are comparable with those found in the literature.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 50 条
  • [41] Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography
    Capel, Camila Porto
    da Motta, Raphael Jurca Goncalves
    Pauwels, Ruben
    Gaeta-Araujo, Hugo
    Oliveira-Santos, Christiano
    Tirapelli, Camila
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (04) : 233 - 239
  • [42] Assessment of mandibular posterior regional landmarks using cone-beam computed tomography in dental implant surgery
    de Souza, Lilian Azevedo
    Souza Picorelli Assis, Neuza Maria
    Ribeiro, Rosangela Almeida
    Pires Carvalho, Antonio Carlos
    Devito, Karina Lopes
    [J]. ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2016, 205 : 53 - 59
  • [43] Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation
    Garcia Silva, Maria Alves
    Wolf, Ulrich
    Heinicke, Frank
    Bumann, Axel
    Visser, Heiko
    Hirsch, Edgar
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) : 640.e1 - 640.e5
  • [44] Quantitative Evaluation of Bone-Related Factors at the Implant Site by Cone-Beam Computed Tomography
    Vasegh Z.
    Safi Y.
    Amid R.
    Ahsaie M.G.
    Amiri M.J.
    Minooei Z.
    [J]. Journal of Long-Term Effects of Medical Implants, 2022, 32 (01) : 33 - 43
  • [45] The Implant Biologic Pontic Designed Interface: Description of the Technique and Cone-Beam Computed Tomography Evaluation
    Pozzi, Alessandro
    Tallarico, Marco
    Moy, Peter K.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E711 - E720
  • [46] Trifurcated Mental Foramina: A Cone-Beam Computed Tomography Incidental Finding During the Implant Treatment Planning
    Vyas, Rutvi
    Gohel, Anita
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [47] Detection of dental root fractures by using cone-beam computed tomography
    Wang, P.
    Yan, X. B.
    Lui, D. G.
    Zhang, W. L.
    Zhang, Y.
    Ma, X. C.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 290 - 298
  • [48] Jumping gap in immediate implant placement in the esthetic zone: A virtual implant planning using cone-beam computed tomography
    Naiem, Suzy Nabil
    Al-Nawas, Bilal
    Tawfik, Omnia Khaled
    El-Nahass, Hani
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (02) : 347 - 353
  • [49] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [50] Cone-beam computed tomography and its applications in dental and maxillofacial radiology
    Schulze, R. K. W.
    Drage, N. A.
    [J]. CLINICAL RADIOLOGY, 2020, 75 (09) : 647 - 657