Contrast vs non-contrast enhanced microvascular imaging using acoustic sub-aperture processing (ASAP) : in vivo demonstration

被引:0
|
作者
Leow, Chee Hau [1 ]
Braga, Marta [2 ]
Bush, Nigel L. [3 ,4 ,5 ]
Stanziola, Antonio [1 ]
Shah, Anant [3 ,4 ,5 ]
Hernandez-Gil, Javier [2 ,6 ]
Long, Nicholas J. [2 ,6 ]
Aboagye, Eric O. [2 ]
Bamber, Jeffrey C. [3 ,4 ,5 ]
Tang, Meng-Xing [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, London, England
[2] Comprehens Canc Imaging Ctr, Dept Surg & Canc, London, England
[3] Inst Canc Res, Joint Dept Phys, London, England
[4] Inst Canc Res, Canc Res UK Canc Imaging Ctr, London, England
[5] Royal Marsden NHS Fdn Trust, London, England
[6] Imperial Coll London, Dept Chem, London, England
关键词
noise reduction; high-frame rate ultrasound; Doppler; CEUS; preclinical in-vivo; ULTRASOUND; DOPPLER; FLOW;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Angiogenesis plays a vital role in the progression of cancer. Non-invasive imaging techniques capable of assessing the microenvironment are therefore of clinical interest. Although highly sensitive vascular mapping has been demonstrated using ultrafast Power Doppler (PD), the detectability of microvasculature from the background noise may be hindered by the low signal-to-noise ratio (SNR) in deeper region and without the use of contrast agents. We recently developed acoustic sub-aperture processing (ASAP) processing for super-contrast vasculature imaging. This technique relies on the spatial coherence of the backscattered echoes over different acquisitions to substantially reduce the noise floor compared to the power Doppler (PD) technique. In this study, we demonstrate the feasibility of applying ASAP processing for non-contrast enhanced microvascular imaging in preclinical condition, and compare it with contrast enhanced ASAP as well as ultrafast PD. Comparing to PD, ASAP exhibit SNR improvement up to 12 dB. Higher SNR and extra visibility of smaller vessel are also demonstrated in contrast enhanced images in comparison to the non-contrast images. In conclusion, we have demonstrated the feasibility of using ASAP in vivo for non-contrast microvascular imaging, and the added benefit of using contrast agents in microvascular imaging.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] NON-CONTRAST DIFFUSION WEIGHTED IMAGING FOR THE ASSESSMENT OF KNEE SYNOVITIS: A COMPARATIVE STUDY AGAINST CONTRAST-ENHANCED MRI
    Oei, E. H.
    McWalter, E. J.
    Sveinsson, B.
    Alley, M. T.
    Hargreaves, B. A.
    Gold, G. E.
    OSTEOARTHRITIS AND CARTILAGE, 2014, 22 : S252 - S252
  • [22] Renal Stone Quantification in Contrast Enhanced CT Using Convolutional Neural Network Assisted Dual-Energy Virtual Non-Contrast Imaging
    Gong, H.
    Ferrero, A.
    Marsh, J.
    Huber, N.
    Fletcher, J.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [23] ASAP: Super-Contrast Vasculature Imaging Using Coherence Analysis and High Frame-Rate Contrast Enhanced Ultrasound
    Stanziola, Antonio
    Leow, Chee Hau
    Bazigou, Eleni
    Weinberg, Peter D.
    Tang, Meng-Xing
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (08) : 1847 - 1856
  • [24] Regional differences of fat depot attenuation using non-contrast, contrast-enhanced, and delayed-enhanced cardiac CT
    Rodriguez-Granillo, Gaston A.
    Capunay, Carlos
    Deviggiano, Alejandro
    De Zan, Macarena
    Carrascosa, Patricia
    ACTA RADIOLOGICA, 2019, 60 (04) : 459 - 467
  • [25] Non-contrast enhanced magnetic resonance imaging for characterization of Fontan associated liver disease
    Langguth, Patrick
    Ravesh, Mona Salehi
    Moritz, Joerg Detlev
    Rinne, Katy
    Harneit, Paul Lennard
    Khodami, Joshua Kian
    Graessner, Joachim
    Uebing, Anselm
    Jansen, Olav
    Both, Marcus
    Hansen, Jan Hinnerk
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 349 : 48 - 54
  • [26] Cardiac imaging with high frame rate contrast enhanced ultrasound: in-vivo demonstration
    Toulemonde, M.
    Li, Y.
    Lin, S.
    Tang, M. X.
    Butler, M.
    Sboros, V.
    Eckersley, R.
    Duncan, W. C.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [27] Non-contrast MRA using an inflow-enhanced, inversion recovery SSFP technique in pediatric abdominal imaging
    Suraj Serai
    Alexander J. Towbin
    Daniel J. Podberesky
    Pediatric Radiology, 2012, 42 : 364 - 368
  • [28] Imaging diseases of the aorta by MRI: a cost-effectiveness analysis of contrast-enhanced studies compared to non-contrast enhanced angiographic studies
    Emer Sonnex
    Melissa L Grzeszczak
    Richard Coulden
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [29] Non-contrast MRA using an inflow-enhanced, inversion recovery SSFP technique in pediatric abdominal imaging
    Serai, Suraj
    Towbin, Alexander J.
    Podberesky, Daniel J.
    PEDIATRIC RADIOLOGY, 2012, 42 (03) : 364 - 368
  • [30] Non-Contrast Perfusion Detection with ARFI Variance of Acceleration (VoA) Imaging: Phantom and In Vivo Results
    Varadarajan, Ramya
    Torres, Gabriela
    Hossain, Md. Murad
    Gallippi, Caterina M.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2252 - 2255