Non-Contrast Perfusion Detection with ARFI Variance of Acceleration (VoA) Imaging: Phantom and In Vivo Results

被引:0
|
作者
Varadarajan, Ramya [1 ]
Torres, Gabriela [1 ]
Hossain, Md. Murad [1 ]
Gallippi, Caterina M. [1 ]
机构
[1] Univ North Carolina & North Carolina State Univ, Joint Dept Biomed Engn, Chapel Hill, NC 27514 USA
关键词
ARFI imaging; perfusion detection; non-contrast imaging; IMPACT; TRACKING; VELOCITY; DISEASE;
D O I
10.1109/ultsym.2019.8926231
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Low blood SNR makes detecting small vessels, measuring slow flow rates, and assessing blood perfusion without contrast administration challenging. A potential approach is to use Variance of Acceleration (VoA) imaging, which has been demonstrated previously in humans in vivo for monitoring subcutaneous bleeding and delineating intraplaque hemorrhage. We hypothesize that, without the addition of contrast agents, VoA can detect slow flow in small vessels for perfusion assessment. Experiments were performed on an ATS 700-D 527 calibrated flow phantom (vessel diameter of 1 mm, flow rates of 0-53 cm/s) and in the surgically exteriorized right kidneys of 3 pigs (2M/1F, mean body weight of 74.4 +/- 9.3 kg) at baseline and after inducing ischemia. In the phantom, logVoA increased in the vessel with increasing flow rate, and it remained constant in the background. LogVoA values were higher in the background with versus without the ARF excitation. Similarly, logVoA values were higher in the vessel, particularly for flow rates < 12 cm/s, with versus without ARF excitation. Vessel CNR by logVoA was higher with versus without ARF excitation for flow rates < 12 cm/s, and CNR by logVoA was greater than CNR by power Doppler for all flow rates. Additionally, logVoA was statistically significantly greater at baseline than ischemia in all three in vivo pig kidneys. Finally, logVoA delineates a 1.25 mm-diameter vessel in a pig renal cortex in vivo, while power Doppler does not. These results suggest that logVoA could support contrast-free detection of slow blood flow in small vessels and in vivo perfusion assessment.
引用
收藏
页码:2252 / 2255
页数:4
相关论文
共 50 条
  • [1] In Vivo Delineation of Carotid Plaque Features with ARFI Variance of Acceleration (VoA): Clinical Results
    Torres, Gabriela
    Czernuszewicz, Tomasz J.
    Homeister, Jonathon W.
    Farber, Mark A.
    Gallippi, Caterina M.
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [2] On the Potential for High Framerate ARFI Variance of Acceleration (VoA) Imaging
    Anand, Keerthi
    Torres, Gabriela
    Gallippi, Caterina
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2318 - 2321
  • [3] ARFI Variance of Acceleration (VoA) for Noninvasive Characterization of Human Carotid Plaques In Vivo
    Torres, Gabriela
    Czernuszewicz, Tomasz J.
    Homeister, Jonathon W.
    Farber, Mark A.
    Gallippi, Caterina M.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2984 - 2987
  • [4] "Perfusion" imaging with non-contrast ultrasound
    Tierney, Jaime E.
    Dumont, Douglas M.
    Byram, Brett C.
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [5] ARFI Variance of Acceleration for Diagnostic Breast Cancer Imaging in Women, in vivo
    Phillips, Anna, V
    Torres, Gabriela
    Steed, Doreen
    Caughey, Melissa C.
    Merhout, Jasmin
    Kirk, Shanah R.
    Hartman, Terry S.
    Kuzmiak, Cherie M.
    Ray, Emily M.
    Gallippi, Caterina M.
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [6] Multiangle PW Compounding Supports ARFI Variance of Acceleration (VoA) Carotid Plaque Imaging for Integration with Vector Doppler
    Anand, Keerthi S.
    Gallippi, Caterina M.
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [7] Combined ARFI Variance of Acceleration (VoA), Vector Flow, and Wall Shear Stress for Assessing Atherosclerotic Risk: Ex-Vivo Human Cadaveric Results
    Anand, Keerthi
    Homeister, Jonathan
    Ezzel, J. Ashley
    Torres, Gabriela
    Gallippi, Caterina M.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [8] Beamforming Improvement for Non-Contrast Perfusion Imaging with Adaptive Demodulation
    Tierney, Jaime
    George, Mark
    Byram, Brett
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [9] Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging
    Tierney, Jaime
    Coolbaugh, Crystal
    Towse, Theodore
    Byram, Brett
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) : 1979 - 1991
  • [10] Carotid Plaque Fibrous Cap Thickness Measurement by ARFI Variance of Acceleration: In Vivo Human Results
    Torres, Gabriela
    Czernuszewicz, Tomasz J.
    Homeister, Jonathon W.
    Farber, Mark A.
    Caughey, Melissa C.
    Gallippi, Caterina M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (12) : 4383 - 4390