Characterization of aqueous two phase systems by combining lab-on-a-chip technology with robotic liquid handling stations

被引:12
|
作者
Amrhein, Sven [1 ]
Schwab, Marie-Luise [1 ]
Hoffmann, Marc [1 ]
Hubbuch, Juergen [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Sect Biomol Separat Engn 4, D-76021 Karlsruhe, Germany
关键词
Aqueous two phase system; Tie line; Density; High throughput; Phase separation; Lab-on-a-chip; Microfluidics; LATEST DEVELOPMENTS; QUANTIFICATION; EQUILIBRIUM; POLYMER;
D O I
10.1016/j.chroma.2014.09.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last decade, the use of design of experiment approaches in combination with fully automated high throughput (HTP) compatible screenings supported by robotic liquid handling stations (LHS), adequate fast analytics and data processing has been developed in the biopharmaceutical industry into a strategy of high throughput process development (HTPD) resulting in lower experimental effort, sample reduction and an overall higher degree of process optimization. Apart from HTP technologies, lab-on-a-chip technology has experienced an enormous growth in the last years and allows further reduction of sample consumption. A combination of LHS and lab-on-a-chip technology is highly desirable and realized in the present work to characterize aqueous two phase systems with respect to tie lines. In particular, a new high throughput compatible approach for the characterization of aqueous two phase systems regarding tie lines by exploiting differences in phase densities is presented. Densities were measured by a standalone micro fluidic liquid density sensor, which was integrated into a liquid handling station by means of a developed generic Tip2World interface. This combination of liquid handling stations and lab-on-a-chip technology enables fast, fully automated, and highly accurate density measurements. The presented approach was used to determine the phase diagram of ATPSs composed of potassium phosphate (pH 7) and polyethylene glycol (PEG) with a molecular weight of 300, 400, 600 and 1000 Da respectively in the presence and in the absence of 3% (w/w) sodium chloride. Considering the whole ATPS characterization process, two complete ATPSs could be characterized within 24 h, including four runs per ATPS for binodal curve determination (less than 45 min/run), and tie line determination (less than 45 min/run for ATPS preparation and 8 h for density determination), which can be performed fully automated over night without requiring man power. The presented methodology provides a cost, time and material effective approach for characterization of ATPS phase diagram on base on highly accurate and comprehensive data. By this means the derived data opens the door for a more detailed description of ATPS towards generating mechanistic based models, since molecular approaches such as MD simulations or molecular descriptions along the line of QSAR heavily rely on accurate and comprehensive data. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [41] Photonic Lab-on-a-Chip analytical systems for nuclear applications: optical performance and UV–Vis–IR material characterization after chemical exposure and gamma irradiation
    Elodie Mattio
    Fabrice Lamadie
    Isaac Rodriguez-Ruiz
    Beatrice Cames
    Sophie Charton
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 323 : 965 - 973
  • [42] A robotic platform to screen aqueous two-phase systems for overcoming inhibition in enzymatic reactions
    Bussamra, Bianca Consorti
    Comes, Joana Castro
    Freitas, Sindelia
    Mussatto, Solange, I
    da Costa, Aline Carvalho
    van der Wielen, Luuk
    Ottens, Marcel
    BIORESOURCE TECHNOLOGY, 2019, 280 : 37 - 50
  • [43] Characterization of Aqueous Two-Phase Systems from Volume and Density Measurements
    Atefi, Ehsan
    Fyffe, Darcy
    Kaylan, Kerim B.
    Tavana, Hossein
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2016, 61 (04): : 1531 - 1539
  • [44] Characterization of Green Fluorescent Protein Using Aqueous Two-Phase Systems
    Umakoshi, Hiroshi
    Nishida, Masato
    Suga, Keishi
    Bui, Huong Thi
    Shimanouchi, Toshinori
    Kuboi, Ryoichi
    SOLVENT EXTRACTION RESEARCH AND DEVELOPMENT-JAPAN, 2009, 16 : 145 - 150
  • [45] PEG-salt aqueous two-phase systems: an attractive and versatile liquid-liquid extraction technology for the downstream processing of proteins and enzymes
    Glyk, Anna
    Scheper, Thomas
    Beutel, Sascha
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2015, 99 (16) : 6599 - 6616
  • [46] Aqueous two-phase system (polyethylene glycol plus ionic liquid) for extraction of α-amylase: phase diagrams, systems characterization and partition study
    Gandolfi, O. R. R.
    Goncalves, G. R. F.
    Batista, I. C.
    Fontan, R. C. I.
    Veloso, C. M.
    Bonomo, R. C. F.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2020, 37 (03) : 595 - 606
  • [47] Axial mixing in a Graesser liquid-liquid contactor using aqueous two-phase systems
    Giraldo-Zuniga, AD
    Coimbra, JSR
    Minim, LA
    Rojas, EEG
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2005, 44 (04) : 441 - 446
  • [48] Representation of liquid-liquid equilibria for polymer-salt aqueous two-phase systems
    Xu, X
    Madeira, PP
    Macedo, EA
    CHEMICAL ENGINEERING SCIENCE, 2004, 59 (05) : 1153 - 1159
  • [49] Liquid-liquid extraction of commercial and biosynthesized nisin by aqueous two-phase micellar systems
    Jozala, A. F.
    Lopes, A. M.
    Mazzola, P. G.
    Magalhdes, P. O.
    Penna, T. C. Vessoni
    Pessoa, A., Jr.
    ENZYME AND MICROBIAL TECHNOLOGY, 2008, 42 (02) : 107 - 112
  • [50] Photonic Lab-on-a-Chip analytical systems for nuclear applications: optical performance and UV-Vis-IR material characterization after chemical exposure and gamma irradiation
    Mattio, Elodie
    Lamadie, Fabrice
    Rodriguez-Ruiz, Isaac
    Cames, Beatrice
    Charton, Sophie
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 323 (02) : 965 - 973