Characterization of aqueous two phase systems by combining lab-on-a-chip technology with robotic liquid handling stations

被引:12
|
作者
Amrhein, Sven [1 ]
Schwab, Marie-Luise [1 ]
Hoffmann, Marc [1 ]
Hubbuch, Juergen [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Sect Biomol Separat Engn 4, D-76021 Karlsruhe, Germany
关键词
Aqueous two phase system; Tie line; Density; High throughput; Phase separation; Lab-on-a-chip; Microfluidics; LATEST DEVELOPMENTS; QUANTIFICATION; EQUILIBRIUM; POLYMER;
D O I
10.1016/j.chroma.2014.09.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last decade, the use of design of experiment approaches in combination with fully automated high throughput (HTP) compatible screenings supported by robotic liquid handling stations (LHS), adequate fast analytics and data processing has been developed in the biopharmaceutical industry into a strategy of high throughput process development (HTPD) resulting in lower experimental effort, sample reduction and an overall higher degree of process optimization. Apart from HTP technologies, lab-on-a-chip technology has experienced an enormous growth in the last years and allows further reduction of sample consumption. A combination of LHS and lab-on-a-chip technology is highly desirable and realized in the present work to characterize aqueous two phase systems with respect to tie lines. In particular, a new high throughput compatible approach for the characterization of aqueous two phase systems regarding tie lines by exploiting differences in phase densities is presented. Densities were measured by a standalone micro fluidic liquid density sensor, which was integrated into a liquid handling station by means of a developed generic Tip2World interface. This combination of liquid handling stations and lab-on-a-chip technology enables fast, fully automated, and highly accurate density measurements. The presented approach was used to determine the phase diagram of ATPSs composed of potassium phosphate (pH 7) and polyethylene glycol (PEG) with a molecular weight of 300, 400, 600 and 1000 Da respectively in the presence and in the absence of 3% (w/w) sodium chloride. Considering the whole ATPS characterization process, two complete ATPSs could be characterized within 24 h, including four runs per ATPS for binodal curve determination (less than 45 min/run), and tie line determination (less than 45 min/run for ATPS preparation and 8 h for density determination), which can be performed fully automated over night without requiring man power. The presented methodology provides a cost, time and material effective approach for characterization of ATPS phase diagram on base on highly accurate and comprehensive data. By this means the derived data opens the door for a more detailed description of ATPS towards generating mechanistic based models, since molecular approaches such as MD simulations or molecular descriptions along the line of QSAR heavily rely on accurate and comprehensive data. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 50 条
  • [1] Design, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology
    Nam-Trung Nguyen
    Shaegh, Seyed Ali Mousavi
    Kashaninejad, Navid
    Dinh-Tuan Phan
    ADVANCED DRUG DELIVERY REVIEWS, 2013, 65 (11-12) : 1403 - 1419
  • [2] Design production and characterization of drug delivery systems by Lab-on-a-Chip technology Preface
    Mazzitelli, Stefania
    Nastruzzi, Claudio
    ADVANCED DRUG DELIVERY REVIEWS, 2013, 65 (11-12) : 1401 - 1402
  • [3] Lab-on-a-Chip Systems in Asphaltene Characterization: A Review of Recent Advances
    Mozaffari, Saeed
    Ghasemi, Homa
    Tchoukov, Plamen
    Czarnecki, Jan
    Nazemifard, Neda
    ENERGY & FUELS, 2021, 35 (11) : 9080 - 9101
  • [4] A disposable lab-on-a-chip platform with embedded fluid actuators for active nanoliter liquid handling
    Björn Samel
    Volker Nock
    Aman Russom
    Patrick Griss
    Göran Stemme
    Biomedical Microdevices, 2007, 9 : 61 - 67
  • [5] A disposable lab-on-a-chip platform with embedded fluid actuators for active nanoliter liquid handling
    Samel, Bjorn
    Nock, Volker
    Russom, Aman
    Griss, Patrick
    Stemme, Goran
    BIOMEDICAL MICRODEVICES, 2007, 9 (01) : 61 - 67
  • [6] Liquid-phase exfoliation of graphite into graphene nanosheets in a hydrocavitating 'lab-on-a-chip'
    Qiu, Xiaoyu
    Bouchiat, Vincent
    Colombet, Damien
    Ayela, Frederic
    RSC ADVANCES, 2019, 9 (06): : 3232 - 3238
  • [7] Gas phase silanization for silicon nanowire sensors and other lab-on-a-chip systems
    Steinbach, Annina M.
    Sandner, Tanja
    Mizaikoff, Boris
    Strehle, Steffen
    PHYSICA STATUS SOLIDI C: CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 13 NO 4, 2016, 13 (04): : 135 - 141
  • [8] A Rapid Method for Estimation of Cariogenic Bacteria Based on a Stationary Liquid Phase Lab-on-a-chip
    Kim, Hee-Jung
    Choi, Suk-Jung
    BIOCHIP JOURNAL, 2018, 12 (01) : 52 - 58
  • [9] A Rapid Method for Estimation of Cariogenic Bacteria Based on a Stationary Liquid Phase Lab-on-a-chip
    Hee-Jung Kim
    Suk-Jung Choi
    BioChip Journal, 2018, 12 : 52 - 58
  • [10] Determination of pore-scale hydrate phase equilibria in sediments using lab-on-a-chip technology
    Almenningen, Stian
    Flatlandsmo, Josef
    Kovscek, Anthony R.
    Ersland, Geir
    Ferno, Martin A.
    LAB ON A CHIP, 2017, 17 (23) : 4070 - 4076