SCREEN-FILM VERSUS FULL-FIELD DIGITAL MAMMOGRAPHY: RADIATION DOSE AND IMAGE QUALITY IN A LARGE TEACHING HOSPITAL

被引:2
|
作者
Stantic, Tomislav J. [1 ]
Ciraj-Bjelac, Olivera E. [2 ]
Stojanovic, Saida S. [3 ]
Basta-Nikolic, Marijana D. [3 ]
Arandjic, Danijela D. [2 ]
Stoiljkovic, Dragana S. [4 ]
机构
[1] Ctr Diagnost, Subotica, Serbia
[2] Univ Belgrade, Vinca Inst Nucl Sci, Radiat Protect Dept, Belgrade, Serbia
[3] Clin Ctr Vojvodina, Novi Sad, Serbia
[4] St Elizabeth Krankenhaus, Bad Kissingen, Germany
来源
关键词
mammography; image quality; radiation dose; mean glandular dose; REFERENCE LEVEL; BREAST; PERFORMANCE; RADIOGRAPHY; ACCURACY; PROGRAM;
D O I
10.2298/NTRP1304398S
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The objective of this paper is to measure the radiation dose and image quality in conventional screen-film mammography and full-field digital mammography in women referred to mammography examination. Participants underwent bilateral, two-view screen-film mammography or full-field digital mammography. The visibility of anatomical regions and overall clinical image quality was rated by experienced radiologists. Total of 387 women and 1548 mammograms were enrolled in the study. Image quality was assessed in terms of image quality score, whereas patient dose assessment was performed in terms of mean glandular dose. Average mean glandular dose for cranio-caudal projection was 1.5 mGy and 2.1 mGy in full-field digital mammography and screen-film mammography, respectively. For medio-lateral oblique projection, corresponding values were 2.3 and 2.1 mGy. Overall image quality criteria scoring was 0.82 and 0.99 for screen-film and digital systems, respectively. The scores were in the range from 0.11 to 1.0 for different anatomical structures. Overall, full-field digital mammography was superior both in terms of image quality and dose over the screen-film mammography. The results have indicated that phantom dose values can assist in setting the optimisation activities in mammography and for comparison between mammography units. To obtain accurate diagnostic information with an acceptable radiation dose to breast, it is necessary to periodically perform patient dose and image quality surveys in all mammography units.
引用
收藏
页码:398 / 405
页数:8
相关论文
共 50 条
  • [21] Screen-film mammography and soft-copy full-field digital mammography: Comparison in the patients with microcalcifications
    Kim, HS
    Han, BK
    Choo, KS
    Jeon, YH
    Kim, JH
    Choe, YH
    KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (04) : 214 - 220
  • [22] Comparison of radiation dose using full field digital and conventional screen-film mammography in a screening clinic
    Gingold, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2100 - 2100
  • [23] Screen-film mammography versus full-field digital mammography in a population-based screening program: The Sogn and Fjordane study
    Juel, Inger-Marie
    Skaane, Per
    Hoff, Solveig Roth
    Johannessen, Gunnar
    Hofvind, Solveig
    ACTA RADIOLOGICA, 2010, 51 (09) : 962 - 968
  • [24] Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    S. Obenauer
    S. Luftner-Nagel
    D. von Heyden
    U. Munzel
    F. Baum
    E. Grabbe
    European Radiology, 2002, 12 : 1697 - 1702
  • [25] Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    Obenauer, S
    Luftner-Nagel, S
    von Heyden, D
    Munzel, U
    Baum, F
    Grabbe, E
    EUROPEAN RADIOLOGY, 2002, 12 (07) : 1697 - 1702
  • [26] Low-contrast lesion detection: Comparison of screen-film and full-field digital mammography
    Hendrick, RE
    Berns, E
    Chorbajian, B
    Choi, K
    Lewin, JM
    Sisney, GA
    RADIOLOGY, 1997, 205 : 569 - 569
  • [27] Comparison of reading time between screen-film mammography and soft-copied, full-field digital mammography
    Ishiyama, Mitsutomi
    Tsunoda-Shimizu, Hiroko
    Kikuchi, Mari
    Saida, Yukihisa
    Hiramatsu, Sonoe
    BREAST CANCER, 2009, 16 (01) : 58 - 61
  • [28] Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications
    Hermann, KP
    Obenauer, S
    Funke, M
    Grabbe, EH
    EUROPEAN RADIOLOGY, 2002, 12 (09) : 2188 - 2191
  • [29] Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications
    K.-P. Hermann
    S. Obenauer
    M. Funke
    E. Grabbe
    European Radiology, 2002, 12 : 2188 - 2191
  • [30] Contrast-detail comparison of a full-field digital mammography system and a screen-film system
    Rosol, MS
    Niklason, LT
    Venkatakrishnan, V
    Silvenoinnen, H
    Kopans, DB
    Hamberg, LM
    RADIOLOGY, 1999, 213P : 151 - 151