Routine Quality Assurance for the MEVION S250 Proton System

被引:0
|
作者
Klein, E. [1 ]
Zhao, T. [1 ]
Grantham, K. [1 ]
Goddu, S. [1 ]
机构
[1] Washington Univ, St Louis, MO USA
关键词
D O I
10.1118/1.4814557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Clinical Commissioning of the Pinnacle Proton Dose Engine for the Mevion S250 Delivery System
    Willoughby, T.
    Zeidan, O.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [2] TOPAS Simulation of the Mevion S250 compact proton therapy unit
    Prusator, Michael
    Ahmad, Salahuddin
    Chen, Yong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03): : 88 - 95
  • [3] A Virtual Machine Source Model for Monte Carlo Simulations of the Mevion S250 Proton System
    Yuan, J.
    Jesseph, Federick
    Cheng, Chee-Wai
    Ellis, Rodney
    Machtay, Mitchell
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E432 - E432
  • [4] Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System
    Prusator, M.
    Jin, H.
    Ahmad, S.
    Chen, Y.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3495 - 3495
  • [5] Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
    Prusator, Michael T.
    Ahmad, Salahuddin
    Chen, Yong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 305 - 310
  • [6] Evaluation of neutron dose equivalent from the Mevion S250 proton accelerator: measurements and calculations
    Chen, Kuan Ling
    Bloch, Charles D.
    Hill, Patrick M.
    Klein, Eric E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24): : 8709 - 8723
  • [7] Accuracy of Eclipse Proton Pencil-Beam Algorithm for Small Brain Targets Using Mevion S250 Proton Therapy System
    Depew, K.
    Ahmad, S.
    Jin, H.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E260 - E260
  • [8] Evaluation of Surface Dose for Various Treatment Sites Using Mevion S250 Passively Scattered Proton Therapy System
    Jin, H.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [9] Patient Specific Quality Assurance Using Machine Log Files for the Mevion S250i Proton Therapy System
    Bunker, A.
    Ahmad, S.
    Chen, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E325 - E325
  • [10] Experimental Assessment of Proton Dose Calculation Accuracy in Small-Field Delivery Using a Mevion S250 Proton Therapy System
    DePew, Kyle D.
    Ahmad, Salahuddin
    Jin, Hosang
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 221 - 229