Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

被引:0
|
作者
Prusator, M.
Jin, H.
Ahmad, S.
Chen, Y.
机构
关键词
D O I
10.1118/1.4956282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-T-146
引用
收藏
页码:3495 / 3495
页数:1
相关论文
共 50 条
  • [1] A Virtual Machine Source Model for Monte Carlo Simulations of the Mevion S250 Proton System
    Yuan, J.
    Jesseph, Federick
    Cheng, Chee-Wai
    Ellis, Rodney
    Machtay, Mitchell
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E432 - E432
  • [2] Clinical Commissioning of the Pinnacle Proton Dose Engine for the Mevion S250 Delivery System
    Willoughby, T.
    Zeidan, O.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [3] TOPAS Simulation of the Mevion S250 compact proton therapy unit
    Prusator, Michael
    Ahmad, Salahuddin
    Chen, Yong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03): : 88 - 95
  • [4] Routine Quality Assurance for the MEVION S250 Proton System
    Klein, E.
    Zhao, T.
    Grantham, K.
    Goddu, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [5] Accuracy of Eclipse Proton Pencil-Beam Algorithm for Small Brain Targets Using Mevion S250 Proton Therapy System
    Depew, K.
    Ahmad, S.
    Jin, H.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E260 - E260
  • [6] Commissioning of a Mevion S250i with Hyperscan Pencil-Beam Scanning Proton Therapy System
    Jin, H.
    Chen, Y.
    Kendall, E.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E325 - E325
  • [7] Systematic Analysis of the Neutron Equivalent Dose in a Mevion S250 Proton Therapy Machine Using Geant4 Monte Carlo Simulation
    Tatari, N.
    Baradaran-Ghahfarokhi, M.
    Roeder, B.
    Zhao, T.
    Khan, R.
    Sobotka, L.
    Darafsheh, A.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit
    Prusator, Michael T.
    Ahmad, Salahuddin
    Chen, Yong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 305 - 310
  • [9] Developing a Monte Carlo model for MEVION S250i with HYPERSCAN and Adaptive Aperture™ pencil beam scanning proton therapy system
    Chiang, Bing-Hao
    Bunker, Austin
    Jin, Hosang
    Ahmad, Salahuddin
    Chen, Yong
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 279 - 286
  • [10] Evaluation of Surface Dose for Various Treatment Sites Using Mevion S250 Passively Scattered Proton Therapy System
    Jin, H.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)