Dose distributions for 90Y intravascular brachytherapy sources used with balloon catheters

被引:6
|
作者
Piessens, M
Reynaert, N
Potempa, J
Thierens, H
Wijns, W
Verbeke, L
机构
[1] Onze Lieve Vrouw Hosp, Dept Radiat Therapy & Oncol, B-9300 Aalst, Belgium
[2] Univ Ghent, Stand Dosimetry Lab, B-9000 Ghent, Belgium
[3] MDS Nordion Haan GmbH, D-42781 Haan, Germany
[4] Onze Lieve Vrouw Hosp, Ctr Cardiovasc, B-9300 Aalst, Belgium
关键词
intravascular brachytherapy; Y-90; Monte Carlo; beta dosimetry; detector intercomparison;
D O I
10.1118/1.1488604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dose distribution around an intravascular brachytherapy Y-90 line source with centering balloon catheters was measured with a plastic scintillator, TLD and radiochromic film. The absolute dose rates measured with the three detectors in a solid water phantom at 1, 2 and 3 mm distance from the centering balloon surfaces are in agreement within 3.5%, when the detectors are calibrated with the same Sr-90/Y-90 source, The dose rates measured with the plastic scintillator in the solid water phantom are in agreement with those directly measured in water. The measured relative dose distributions can be reproduced by Monte Carlo calculations. Also, the influence of the balloon diameter on the dose rate can be reproduced by the calculations. The dose rate calibration routinely performed with the plastic scintillator was checked for fifty-one sources with a well chamber and with another dedicated dose rate checking device. These measurements show that the consistency of the calibration of these sources was better than 10%. In a previous paper absolute dose rates for five other 90Y sources measured with TLD and radiochromic film in a solid water phantom were compared with those obtained with the plastic scintillator in water [Piessens and Reynaert, "Verification of absolute dose rates for intravascular beta sources," Phys. Med. Biol. 45, 2219-2231 (2000)]. Differences of 25 to 41%. depending on the balloon diameter, were reported, In this paper we show the evidence for three main reasons for these previously observed discrepancies: an inconsistency between a detector calibration performed with a 6 MeV electron beam and with a calibrated Sr-90/Y-90 source from NIST (16%), inaccuracies of the measuring distances in the solid water phantom (maximum 7.5%) and a time instability of the plastic scintillator, probably due to radiation damage (6%). (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:1562 / 1571
页数:10
相关论文
共 50 条
  • [41] Microdosimetry of Simulated Heterogeneous 177Lu and 90Y Activity Distributions
    Grimes, J.
    Celler, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [42] Stepping of Sr/Y-90 source trains revisit in intravascular brachytherapy
    Yang, NC
    Chan, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1226 - 1226
  • [43] Accuracy of in vivo 90Y activity and dose quantification based on 90Y-PET/CT following 90Y-Radioembolization
    Henry, E. Courtney
    Lopez, Benjamin
    Kappadath, S. Cheenu
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [44] Characterization of a high-dose-rate 90Sr-90Y source for intravascular brachytherapy by using the Monte Carlo code PENELOPE
    Asenjo, J
    Fernández-Varea, JM
    Sánchez-Reyes, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05): : 697 - 711
  • [45] Dose perturbation caused by stents:: Experiments with a model 90Sr/90Y source
    Wilczek, Krzysztof
    Petelenz, Barbara
    Strzala, Alicja
    Marczewska, Barbara
    Traczyk, Marek
    Polonski, Lech
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (05) : 981 - 991
  • [46] Dose Perturbation Caused by Stents: Experiments with a Model 90Sr/90Y Source
    Krzysztof Wilczek
    Barbara Petelenz
    Alicja Strzała
    Barbara Marczewska
    Marek Traczyk
    Lech Poloński
    CardioVascular and Interventional Radiology, 2007, 30 : 981 - 991
  • [47] Comparative Study of Biologic Effective Dose for the Beta Emitters 142Pr and 90Y and Their Applications in Microsphere Brachytherapy of Hepatocellular Carcinoma
    Ferreira, M.
    Podder, T. K.
    Jung, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S859 - S859
  • [48] 90Y Bremsstrahlung Imaging for Absorbed-Dose Assessment in High-Dose Radioimmunotherapy
    Minarik, David
    Sjogreen-Gleisner, Katarina
    Linden, Ola
    Wingardh, Karin
    Tennvall, Jan
    Strand, Sven-Erik
    Ljungberg, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (12) : 1974 - 1978
  • [49] Radiation dose to abdominal organs of the mouse due to 90Y in the urinary bladder
    Lazewatsky, J
    Ding, YH
    Onthank, D
    Silva, P
    Solon, E
    Robinson, S
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2003, 18 (03) : 413 - 419
  • [50] Technical note: The contribution of internal bremsstrahlung to the 90Y dose point kernel
    Auditore, Lucrezia
    Amato, Ernesto
    Pistone, Daniele
    Italiano, Antonio
    MEDICAL PHYSICS, 2023, 50 (03) : 1865 - 1870