Cardiac output monitoring by pressure recording analytical method in cardiac surgery

被引:75
|
作者
Giomarelli, P [1 ]
Biagioli, B [1 ]
Scolletta, S [1 ]
机构
[1] Univ Siena, Dept Surg & Bioengn, Thorac & Cardiovasc Unit, I-53100 Siena, Italy
关键词
cardiac output; monitoring; pulse contour; coronary artery bypass grafting;
D O I
10.1016/j.ejcts.2004.05.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: A less-invasive method has been developed that may provide an alternative to monitor cardiac output from arterial pressure: beat-to-beat values of cardiac output can be obtained by pressure recording analytical method (PRAM). The purpose of this study was to assess the reliability of cardiac output determination by PRAM in cardiac surgery. Methods: Cardiac output was measured in 28 patients undergoing coronary artery bypass grafting at 15 min after anaesthesia induction, 30 min after extracorporeal circulation, 1 and 3 h after arrival in the intensive care unit using thermodilution (ThD) method through a pulmonary artery catheter and PRAM. ThD cardiac output was calculated as the mean of five separate measurements. PRAM provided beat-by-beat cardiac output data continuously throughout the study and the cardiac output values displayed on a dedicated personal computer at each time point were recorded. Correlations were calculated and differences were compared by Bland-Altman analysis. Results: A total of 112 measurements were obtained. Cardiac output ranged from 2.3 to 7.4 l/min, and a good linear correlation (R-2 = 0.78, P < 0.0001) was found between ThD and PRAM. The highest degree of correlation (R-2 = 0.86) was obtained at 3 It after arrival in the intensive care unit. The lower degree of correlation (R-2 = 0.70) was obtained 30 min after extracorporeal circulation. At Bland-Altman analysis, the overall estimates of cardiac output measured by PRAM closely agreed with ThD (mean difference, 0.027; standard deviation, 0.43; limits of agreement, -0.83 and +0.89). Conclusions: Under the studied conditions, our results demonstrate good agreement between PRAM data and ThD measurements, and this new method has shown to be accurate for real-time monitoring of cardiac output in cardiac surgery. Further studies will be required to assess this method in higher-risk patients and in the setting of haemodynamic instability or arrhythmias. This is the first study designed to assess the accuracy of PRAM in cardiac surgery. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:515 / 520
页数:6
相关论文
共 50 条
  • [21] Pulse Wave Analysis Using the Pressure Recording Analytical Method to Measure Cardiac Output in Pediatric Cardiac Surgery Patients: A Method Comparison Study Using Transesophageal Doppler Echocardiography as Reference Method
    Greiwe, Gillis
    Balfanz, Vanessa
    Hapfelmeier, Alexander
    Zajonz, Thomas S.
    Mueller, Matthias
    Saugel, Bernd
    Schulte-Uentrop, Leonie
    ANESTHESIA AND ANALGESIA, 2022, 135 (01): : 71 - 78
  • [22] Cardiac output monitoring in paediatric cardiac surgery: a review
    Woodman, Hannah M.
    Lee, Corlyn
    Ahmed, Ayesha N.
    Malik, Bassit A.
    Mellor, Sophie
    Brown, Louise J.
    Gentle, Leanne
    Harky, Amer
    CARDIOLOGY IN THE YOUNG, 2021, 31 (01) : 23 - 30
  • [23] Measurement of cardiac output in children: comparison between direct Fick method and pressure recording analytical method: preliminary report
    J Alonso Iñigo
    F Escribá
    J Carrasco
    J Encarnación
    M Fas
    M Barberá
    Critical Care, 19 (Suppl 1):
  • [24] A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
    Angela Briganti
    Flavia Evangelista
    Paola Centonze
    Annaliso Rizzo
    Francesco Bentivegna
    Antonio Crovace
    Francesco Staffieri
    BMC Veterinary Research, 14
  • [25] A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs
    Briganti, Angela
    Evangelista, Flavia
    Centonze, Paola
    Rizzo, Annaliso
    Bentivegna, Francesco
    Crovace, Antonio
    Staffieri, Francesco
    BMC VETERINARY RESEARCH, 2018, 14
  • [26] Assessment of Modified Ultrafiltration Hemodynamic Impact by Pressure Recording Analytical Method During Pediatric Cardiac Surgery
    Ricci, Zaccaria
    Polito, Angelo
    Netto, Roberta
    De Razza, Francesca
    Favia, Isabella
    Carotti, Adriano
    Cogo, Paola E.
    PEDIATRIC CRITICAL CARE MEDICINE, 2013, 14 (04) : 390 - 395
  • [27] FloTrac for monitoring arterial pressure and cardiac output during phaeochromocytoma surgery
    Collange, O.
    Xavier, L.
    Kuntzman, H.
    Calon, B.
    Schaeffer, R.
    Pottecher, T.
    Diemunsch, P.
    Pessaux, P.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (09) : 779 - 780
  • [28] A NEW METHOD FOR DIRECT RECORDING OF CARDIAC OUTPUT
    BRECHER, GA
    HUBAY, CA
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1954, 86 (03): : 464 - 469
  • [29] Perioperative Continuous Noninvasive Cardiac Output Monitoring in Cardiac Surgery Patients by a Novel Capnodynamic Method
    Tusman, Gerardo
    Acosta, Cecilia M.
    Wallin, Mats
    Hallback, Magnus
    Esperatti, Mariano
    Peralta, Georgina
    Eugenia Gonzalez, Maria
    Suarez-Sipmann, Fernando
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (08) : 2900 - 2907
  • [30] SIMPLE METHOD FOR DETERMINING CARDIAC OUTPUT DURING CARDIAC SURGERY
    FLETCHER, JR
    ANNALS OF THORACIC SURGERY, 1974, 17 (01): : 16 - 19