Assessment of Modified Ultrafiltration Hemodynamic Impact by Pressure Recording Analytical Method During Pediatric Cardiac Surgery

被引:25
|
作者
Ricci, Zaccaria [1 ]
Polito, Angelo [1 ]
Netto, Roberta [1 ]
De Razza, Francesca [1 ]
Favia, Isabella [1 ]
Carotti, Adriano [2 ]
Cogo, Paola E. [1 ]
机构
[1] Bambino Gesu Pediat Hosp, IRCCS, Dept Pediat Cardiol & Cardiac Surg, Pediat Cardiac Anesthesia Intens Care Unit, Rome, Italy
[2] Bambino Gesu Pediat Hosp, IRCCS, Dept Pediat Cardiol & Cardiac Surg, Rome, Italy
关键词
cardiac output; cardiopulmonary bypass; congenital heart disease; modified ultrafiltration; pediatric cardiac surgery; pulse contour monitoring; PULSE CONTOUR METHOD; CARDIOPULMONARY BYPASS; OUTPUT; CHILDREN; PARAMETERS;
D O I
10.1097/PCC.0b013e31828a7113
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective:: Modified ultrafiltration is commonly used in pediatric cardiac surgery. Although its clinical benefits are currently debated, modified ultrafiltration has proved to improve mean arterial pressure in the first postoperative hours. Aim of our study was to measure cardiac index, stroke volume index, and mean arterial pressure modification before and after modified ultrafiltration by means of Pressure Recording Analytical Method. Design:: Single-center prospective observational cohort study. Setting:: Pediatric cardiac surgery operating room. Patients:: Children below 20 kg that are included in the "pediatric" mode of Pressure Recording Analytical Method. Measurements and Main Results: Forty patients were enrolled in this study. Median age, weight, and body surface area at surgery were 3 months (interquartile range, 10 days to 3.5 yr), 5.6 (3.1-15) kg, and 0.31 (0.21-0.56), respectively. During the modified ultrafiltration procedure, a median volume of 17 mL/kg (11-25) was ultrafiltered and a median volume of 11 mL/kg (6-17) was reinfused with a median final modified ultrafiltration balance of -0.15 mL/kg (-4.0 to 0.1). By univariate analyses, there was a 10% increase in postmodified ultrafiltration mean, systolic and diastolic pressures (p = 0.01), stroke volume index (p = 0.02), and cardiac index (p = 0.001) without significant changes in heart rate, central (left and right) venous pressures, stroke volume variation, and inotropic score. By multivariate analysis, when controlling for cardiopulmonary bypass time and age at surgery, cardiac index variation was independently associated with lower preoperative body surface area (beta coefficient -5.5, p = 0.04). Conclusions: According to Pressure Recording Analytical Method assessment, modified ultrafiltration acutely improves myocardial function, as shown by a 10% increase of systemic arterial pressure, stroke volume index, and cardiac index. This effect is more pronounced in smaller sized patients
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [1] Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery
    Garisto, Cristiana
    Favia, Isabella
    Ricci, Zaccaria
    Romagnoli, Stefano
    Haiberger, Roberta
    Polito, Angelo
    Cogo, Paola
    PEDIATRIC ANESTHESIA, 2015, 25 (02) : 143 - 149
  • [2] Measurement of cardiac output by PRAM (Pressure Recording Analytical Method): relevance in pediatric cardiac surgery
    Amrani, O.
    Brisard, L.
    Videcoq, M.
    Fernandez, M.
    Berard, L.
    De Windt, A.
    Lejus, C.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A284 - A285
  • [3] Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    Giomarelli, P
    Biagioli, B
    Scolletta, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) : 515 - 520
  • [4] MODIFIED ULTRAFILTRATION IN PEDIATRIC CARDIAC-SURGERY
    PEDERSEN, J
    HJORTHOLM, K
    SLOTH, E
    HANSEN, OK
    DITLEVSEN, E
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 39 - 39
  • [5] Pro: The use of modified ultrafiltration during pediatric cardiac surgery is a benefit
    Montenegro, LM
    Greeley, WJ
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (04) : 480 - 482
  • [6] Modified and conventional ultrafiltration during pediatric cardiac surgery: Clinical outcomes compared
    Williams, Glyn D.
    Ramamoorthy, Chandra
    Chu, Larry
    Hammer, Gregory B.
    Kamra, Komal
    Boltz, Madalane G.
    Pentcheva, Krassimira
    McCarthy, James P.
    Reddy, Vadiyala M.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (06): : 1291 - 1298
  • [7] Safety and utility of modified ultrafiltration in pediatric cardiac surgery
    Palanzo, David A.
    Wise, Robert K.
    Woitas, Karl R.
    Undar, Akif
    Clark, Joseph B.
    Myers, John L.
    PERFUSION-UK, 2023, 38 (01): : 150 - 155
  • [8] Cardiac index assessment by the pressure recording analytical method in infants after paediatric cardiac surgery: a pilot retrospective study
    Favia, Isabella
    Rizza, Alessandra
    Garisto, Cristiana
    Haiberger, Roberta
    Di Chiara, Luca
    Romagnoli, Stefano
    Ricci, Zaccaria
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (06) : 919 - 923
  • [9] HEMODYNAMIC ANALYSIS OF PEDIATRIC SEPTIC SHOCK USING PRESSURE RECORDING ANALYTICAL METHOD IN PEDIATRIC INTENSIVE CARE UNIT
    Setyaningtyas, A.
    Pudjiadi, A.
    Endaryanto, A.
    Soetjipto, S.
    PEDIATRIC CRITICAL CARE MEDICINE, 2022, 23 (11)
  • [10] Removal of prostaglandin E2 and increased intraoperative blood pressure during modified ultrafiltration in pediatric cardiac surgery
    Yokoyama, Kazuto
    Takabayashi, Shin
    Komada, Takuya
    Onoda, Koji
    Mitani, Yoshihide
    Iwata, Hideki
    Shimpo, Hideto
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (03): : 730 - 735