STUDY OF ENERGY CONSUMPTION OF AIR SOURCE HEAT PUMP DEFROST

被引:0
|
作者
Liu, S. G. [1 ]
Han, Z. T. [1 ]
Zhou, C. [1 ]
Li, X. [1 ]
Yao, Y. [2 ]
机构
[1] Northeast Forestry Univ, Sch Civil Engn, Harbin 150040, Peoples R China
[2] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin 150090, Peoples R China
关键词
Air source heat pump; Defrost; Energy consumption; Experimental study;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy consumption of a split air source heat pump defrosting is analyzed in detail. In a small artificial climate chamber, the multi-conditions frost/defrost experiments of a heat pump prototype had been carried out, and many defrosting parameters such as the system pressure, temperature, power etc. were measured. Through theoretical calculation and experimental data analysis some important characteristics of defrosting were obtained. The air source heat pump compressor work, inherent component cooling and heat absorbed from the indoor environment can be looked as the three main parts of the defrosting energy consumption. This paper's experimental results will provide the basis for optimization of the air-source heat pump system design and defrosting control methods.
引用
收藏
页码:880 / 886
页数:7
相关论文
共 50 条
  • [21] Simulation and Analysis of Air-Soil Dual Source Heat Pump Energy Consumption in Cold Regions
    Wang, Hongwei
    Bai, Bing
    Feng, Guohui
    Yu, Liang
    Liu, Xing
    Luo, Ying
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1397 - 1405
  • [22] Experiment study on performance of air source heat pump
    Shi, Weixiu
    Pan, Lisheng
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 645 - +
  • [23] Experimental study of an improved air source heat pump
    Ding, YJ
    Chai, QH
    Ma, GY
    Jiang, Y
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (15-16) : 2393 - 2403
  • [24] Experimental study of an improved air source heat pump
    Chai, QH
    Ma, GY
    Jiang, Y
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 881 - 887
  • [25] An experimental study on energy saving analysis in the defrost cycle of residential heat pumps with the use of reverse air flow during defrost
    Muthusubramanian, Kamalakkannan
    Shooshtari, Amir H.
    Dessiatoun, Serguei V.
    Ohadi, Michael M.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (04) : 608 - 618
  • [26] An experimental investigation on hot gas defrost of air-source transcritical CO2 heat pump systems
    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an
    710049, China
    Hsi An Chiao Tung Ta Hsueh, 3 (74-79):
  • [27] Field test investigation of the characteristics for the air source heat pump under two typical mal-defrost phenomena
    Wang, W.
    Xiao, J.
    Guo, Q. C.
    Lu, W. P.
    Feng, Y. C.
    APPLIED ENERGY, 2011, 88 (12) : 4470 - 4480
  • [28] Performances of air source heat pump system for a kind of mal-defrost phenomenon appearing in moderate climate conditions
    Wang, W.
    Feng, Y. C.
    Zhu, J. H.
    Li, L. T.
    Guo, Q. C.
    Lu, W. P.
    APPLIED ENERGY, 2013, 112 : 1138 - 1145
  • [29] SIMULATION AND ANALYSIS OF DYNAMIC ENERGY CONSUMPTION OF A SEAWATER SOURCE HEAT PUMP
    Hu, Songtao
    Cao, Yu
    Liu, Kai
    Wang, Gang
    Song, Wei
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2011 - 2017
  • [30] Study on the model of energy consumption and the land subsidence due to water-source heat pump
    Li, Yong
    Guan, Changsheng
    Li, Ji-Lin
    International Journal of Applied Environmental Sciences, 2013, 8 (04): : 437 - 447