Comparison of blood pressure measurements of anesthetized dogs obtained noninvasively with a cylindrical blood pressure cuff and an anatomically modified conical blood pressure cuff

被引:0
|
作者
Ramos, Sara J. [1 ]
da Cunha, Anderson F. [1 ]
Domingues, Michelle [1 ]
Shelby, Amanda M. [1 ]
Stout, Rhett W. [2 ]
Acierno, Mark J. [1 ]
机构
[1] Louisiana State Univ, Sch Vet Med, Dept Vet Clin Sci, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Sch Vet Med, Div Lab Anim Med, Baton Rouge, LA 70803 USA
关键词
SYSTEMIC HYPERTENSION; AGREEMENT; MONITOR; GUIDELINES; DIAGNOSIS; CATS;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To compare blood pressure measured noninvasively with an oscillometric device that involved use of a novel conical cuff and a traditional cylindrical blood pressure cuff. ANIMALS 17 adult hound-type dogs. PROCEDURES Dogs were anesthetized, and a 20-gauge, 1.5-inch catheter was inserted in the median sacral artery. The catheter was attached to a pressure transducer via fluid-filled noncompliant tubing, and direct blood pressure was recorded with a multifunction monitor. A specially fabricated conical cuff was placed on the antebrachium. Four sets of direct and indirect blood pressure measurements were simultaneously collected every 2 minutes. Four sets of measurements were then obtained by use of a cylindrical cuff. RESULTS The cylindrical cuff met American College of Veterinary Internal Medicine consensus guidelines for validation of indirect blood pressure measurements for mean arterial blood pressure (MAP), systolic arterial blood pressure (SAP), and diastolic arterial blood pressure (DAP). The conical cuff met the consensus guidelines for difference of paired measurements, SD, and percentages of measurements within 10 and 20 mm Hg of the value for the reference method, but it failed a correlation analysis. In addition, although bias for the conical cuff was less than that for the cylindrical cuff for SAP, MAP, and DAP measurements, the limits of agreement for the conical cuff were wider than those for the cylindrical cuff for SAP and MAP measurements. CONCLUSIONS AND CLINICAL RELEVANCE On the basis of results of this study, use of a conical cuff for oscillometric blood pressure measurement cannot be recommended.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [21] Pediatric blood pressure standards by circumference-based blood pressure cuff
    Park, MK
    Menard, SW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 481A - 481A
  • [22] A Conical Cuff and Other Stuff: Blood Pressure Monitoring in the Obese is Tough
    Wanderer, Jonathan P.
    Nathan, Naveen
    ANESTHESIA AND ANALGESIA, 2019, 128 (03): : 390 - 390
  • [23] Validation of a conical cuff on the forearm for estimating radial artery blood pressure
    Hersh, Lawrence T.
    Sesing, Jean C.
    Luczyk, William J.
    Friedman, Bruce A.
    Zhou, Shanggen
    Batchelder, Paul B.
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 38 - 45
  • [24] Relationship between brachial blood pressure obtained by cuff method and central blood pressure measured with invasive method
    Kobayashi, H.
    Kino, M.
    Hokama, Y.
    Ohshima, K.
    Sugo, Y.
    Kojima, I.
    Miyawaki, Y.
    Takazawa, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 265 - 265
  • [25] Correlation Between the Brachial Blood Pressure Values Obtained Using the Cuff Method and the Central Blood Pressure Values Obtained Invasively
    Kobayashi, Hiroshi
    Kinou, Mineko
    Takazawa, Kenji
    INTERNAL MEDICINE, 2013, 52 (15) : 1675 - 1680
  • [26] THE OPTIMUM SIZE CUFF FOR AUSCULTATORY BLOOD PRESSURE MEASUREMENTS IN CHILDREN
    MOSS, AJ
    ADAMS, FH
    DIXON, WJ
    HUGGINS, M
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1960, 100 (04): : 617 - 617
  • [27] Arm and forearm blood pressure measurements as a function of cuff width
    Moura Arcuri, Edna Apparecida
    Denzin Rosa, Solange Cristina
    Scanavini, Rosa Maria
    Cardin Denzin, Gesiane de Salles
    ACTA PAULISTA DE ENFERMAGEM, 2009, 22 (01) : 37 - 42
  • [28] Effect of Cuff Design on Auscultatory and Oscillometric Blood Pressure Measurements
    Ringrose, Jennifer S.
    McLean, Donna
    Ao, Peter
    Yousefi, Farahnaz
    Sankaralingam, Sowndramalingam
    Millay, Jack
    Padwal, Raj
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (09) : 1063 - 1069
  • [29] The impact of sphygmomanometer placement and cuff placement on blood pressure measurements
    Zhu, Xiao-Yong
    Zhang, Pu-Hua
    Huang, Wen-Yin
    Huang, Wan
    Tang, Xin-Hu
    Yu, Hua
    Wang, Su-Nan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [30] Wrist Cuff Method Determines Diastolic Pressure in Dual Cuff Blood Pressure System
    Jilek, Jiri
    Stork, Milan