Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

被引:32
|
作者
Tang, Hao [1 ,2 ]
Ding, Yong [1 ,2 ]
Singer, Brett C. [3 ]
机构
[1] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[3] Lawrence Berkeley Natl Lab, Energy Technol Area, Indoor Environm Grp, Berkeley, CA 94720 USA
来源
基金
中国国家自然科学基金;
关键词
Thermal environment; Sound; Visual environment; Indoor air quality; Perceived IEQ; GREEN OFFICE BUILDINGS; HEALTH-CARE FACILITIES; THERMAL COMFORT; OCCUPANT SATISFACTION; PM2.5; PRODUCTIVITY; INFORMATION; PERFORMANCE; POLLUTANTS; PARAMETERS;
D O I
10.1016/j.jobe.2020.101649
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote - predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m(3) in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] On a Post-occupancy Evaluation Study of Effects of Occupant Behavior on Indoor Environment Quality in College Buildings in Chongqing
    Yu, Xiaoping
    Liu, Liying
    Wu, Xu
    Wu, Xiaolin
    Wang, Zhimao
    Liu, Qing
    Shi, Guobing
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 623 - 627
  • [2] Post-Occupancy Indoor Environmental Quality Evaluation of Student Housing Facilities
    Hassanain, Mohammad A.
    [J]. ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2007, 3 (04) : 249 - 256
  • [3] Post-occupancy evaluation in indoor comfort conditions for green office buildings
    Aycam, Idil
    Gorgulu, Leyla Senem
    Soyluk, Asena
    [J]. GRADEVINAR, 2022, 74 (09): : 721 - 737
  • [4] Productivity metrics in dynamic LCA for whole buildings: Using a post-occupancy evaluation of energy and indoor environmental quality tradeoffs
    Collinge, William O.
    Landis, Amy E.
    Jones, Alex K.
    Schaefer, Laura A.
    Bilec, Melissa M.
    [J]. BUILDING AND ENVIRONMENT, 2014, 82 : 339 - 348
  • [5] Association between Building Characteristics and Indoor Environmental Quality through Post-Occupancy Evaluation
    Bortolini, Rafaela
    Forcada, Nuria
    [J]. ENERGIES, 2021, 14 (06)
  • [6] Post-Occupancy Evaluation of library buildings
    Sbiroli, Maria Chiara
    [J]. AIB STUDI, 2013, 53 (02): : 17 - 28
  • [7] Post-occupancy evaluation of University of Uyo buildings
    Ikediashi, Dubem
    Udo, Godfrey
    Ofoegbu, Maureen
    [J]. JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2020, 18 (06) : 1711 - 1730
  • [8] Post-Occupancy evaluation of office buildings' indoor environmental quality from the perspectives of architects and non-architects (case study: Iran)
    Rahanjam, By Ashkan
    Ilbeigi, Marjan
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 42
  • [9] Indoor Environmental Quality Assessment and Occupant Satisfaction: A Post-Occupancy Evaluation of a UAE University Office Building
    Kim, Young Ki
    Abdou, Yasmin
    Abdou, Alaa
    Altan, Hasim
    [J]. BUILDINGS, 2022, 12 (07)
  • [10] Scoping review of post occupancy evaluation of office buildings with focus on indoor environmental quality and productivity
    -Krogh, Emilie Patricia Dam
    Rupp, Ricardo Forgiarini
    Clausen, Geo
    Toftum, Jorn
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 86