Post-occupancy evaluation of University of Uyo buildings

被引:12
|
作者
Ikediashi, Dubem [1 ]
Udo, Godfrey [2 ]
Ofoegbu, Maureen [1 ]
机构
[1] Univ Uyo, Dept Bldg, Uyo, Nigeria
[2] Univ Uyo, Dept Estate Management, Uyo, Nigeria
关键词
Nigeria; Barriers; Performance evaluation; University buildings; Functional performance; Technical performance;
D O I
10.1108/JEDT-11-2019-0303
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose This study aims to evaluate the performance of buildings in the University of Uyo using the post-occupancy evaluation (POE) technique. Design/methodology/approach A quantitative questionnaire survey is adopted in which 333 copies of a validated questionnaire are administered to academic, administrative and maintenance staff and some students who occupy four buildings used for the survey. However, 124 valid responses are received giving a response rate of 37per cent. Data collected are analysed using descriptive and inferential statistical tools while the Kruskal Wallis chi-square (chi(2)) test is used to analyse hypotheses postulated for the study. Findings Findings reveal that the General Administration (GA) building has high ratings in five technical performance criteria of ambient level of sound in offices, the integrity of materials used for walls, and correctness of stair risers, threads in the building quality of lighting and quantity of lighting. Findings on the functional performance of GA building show that cleaning, friendliness, parking space, landscaping and indoor climate are the top five rated. Findings also reveal that lack of awareness about POE is a top-rated barrier, followed by a lack of orientation of stakeholders and a lack of adequately trained staff. Originality/value The study contributes to the body of knowledge on POE, particularly in universities by conducting an empirical evaluation of both technical and functional performance of the University of Uyo buildings. Besides, it establishes a set of factors that significantly hinder the implementation of POEs in universities. From a practice perspective, it provides valid feedback on which universities can build upon to improve conditions of their facilities and ultimately bolster the conducive environment for teaching and learning.
引用
下载
收藏
页码:1711 / 1730
页数:20
相关论文
共 50 条
  • [1] Post-Occupancy Evaluation of library buildings
    Sbiroli, Maria Chiara
    AIB STUDI, 2013, 53 (02): : 17 - 28
  • [2] Post-occupancy evaluation of a university student cafeteria
    Hassanain, Mohammad A.
    Mathar, Hasan
    Aker, Ameer
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2016, 12 (01) : 67 - 77
  • [3] POST-OCCUPANCY EVALUATION OF A UNIVERSITY SHOPPING MALL FACILITY
    Ahmed, Wahhaj
    Hassanain, Mohammad A.
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2020, 13 (02) : 5 - 15
  • [4] The need for post-occupancy evaluation of public apartment buildings in Ghana
    Agyefi-Mensah, S.
    Post, Jouke
    van Egmond, Emilia
    Badu, Edward
    Mohammadi, Masi
    JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2015, 13 (02) : 315 - 333
  • [5] POST-OCCUPANCY EVALUATION - AN OVERVIEW
    ZIMRING, CM
    REIZENSTEIN, JE
    ENVIRONMENT AND BEHAVIOR, 1980, 12 (04) : 429 - 450
  • [6] Who is post-occupancy evaluation for?
    Roberts, P
    BUILDING RESEARCH AND INFORMATION, 2001, 29 (06): : 463 - 465
  • [7] Post-occupancy evaluation in indoor comfort conditions for green office buildings
    Aycam, Idil
    Gorgulu, Leyla Senem
    Soyluk, Asena
    GRADEVINAR, 2022, 74 (09): : 721 - 737
  • [8] Post occupancy evaluation of university educational buildings
    Gabr, HS
    Al-Sallal, KA
    PEOPLE, PLACES AND SUSTAINABILITY, 2003, : 229 - 242
  • [9] RATEWORKSPACE: BIM INTEGRATED POST-OCCUPANCY EVALUATION SYSTEM FOR OFFICE BUILDINGS
    Artan, Deniz
    Ergen, Esin
    Kula, Behlul
    Guven, Gursans
    JOURNAL OF INFORMATION TECHNOLOGY IN CONSTRUCTION, 2022, 27 : 441 - 485
  • [10] Post-occupancy evaluation of office buildings in a Johannesburg country club estate
    Emuze, Fidelis
    Mashili, Humbulani
    Botha, Brink
    ACTA STRUCTILIA, 2013, 20 (01) : 89 - 110