Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

被引:32
|
作者
Tang, Hao [1 ,2 ]
Ding, Yong [1 ,2 ]
Singer, Brett C. [3 ]
机构
[1] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[3] Lawrence Berkeley Natl Lab, Energy Technol Area, Indoor Environm Grp, Berkeley, CA 94720 USA
来源
基金
中国国家自然科学基金;
关键词
Thermal environment; Sound; Visual environment; Indoor air quality; Perceived IEQ; GREEN OFFICE BUILDINGS; HEALTH-CARE FACILITIES; THERMAL COMFORT; OCCUPANT SATISFACTION; PM2.5; PRODUCTIVITY; INFORMATION; PERFORMANCE; POLLUTANTS; PARAMETERS;
D O I
10.1016/j.jobe.2020.101649
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote - predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m(3) in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Post-occupancy evaluation of green buildings: the measured impact of over-glazing
    Byrd, Hugh
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2012, 55 (03) : 206 - 212
  • [32] INFORMATION RESOURCES FOR POST-OCCUPANCY EVALUATION
    MURTHA, DM
    [J]. JOURNAL OF ARCHITECTURAL AND PLANNING RESEARCH, 1988, 5 (04) : 321 - 338
  • [33] Benchmarking for post-occupancy evaluation of hospitals
    Liao, Pinchao
    Xue, Jiawei
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2013, 53 (09): : 1273 - 1276
  • [34] Post-occupancy evaluation: benefits and barriers
    Zimmerman, A
    Martin, M
    [J]. BUILDING RESEARCH AND INFORMATION, 2001, 29 (02): : 168 - 174
  • [35] Post-occupancy evaluation - where are you?
    Cooper, I
    [J]. BUILDING RESEARCH AND INFORMATION, 2001, 29 (02): : 158 - 163
  • [36] Post-occupancy evaluation: a review of literature
    Roberts, C. J.
    Edwards, David John
    Hosseini, M. Reza
    Mateo-Garcia, Monica
    Owusu-Manu, De-Graft
    [J]. ENGINEERING CONSTRUCTION AND ARCHITECTURAL MANAGEMENT, 2019, 26 (09) : 2084 - 2106
  • [37] A critique of post-occupancy evaluation in the UK
    Isaiah Oluremi Durosaiye
    Karim Hadjri
    Champika Lasanthi Liyanage
    [J]. Journal of Housing and the Built Environment, 2019, 34 : 345 - 352
  • [38] A critique of post-occupancy evaluation in the UK
    Durosaiye, Isaiah Oluremi
    Hadjri, Karim
    Liyanage, Champika Lasanthi
    [J]. JOURNAL OF HOUSING AND THE BUILT ENVIRONMENT, 2019, 34 (01) : 345 - 352
  • [39] Sustainable development and post-occupancy evaluation
    Fisk, D
    [J]. BUILDING RESEARCH AND INFORMATION, 2001, 29 (06): : 466 - 468
  • [40] Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing on indoor air quality (IAQ). Assessment by questionnaires and physical measurements
    Silva, Marielle Ferreira
    Maas, Stefan
    de Souza, Henor Artur
    Gomes, Adriano Pinto
    [J]. ENERGY AND BUILDINGS, 2017, 148 : 119 - 127