Respiration Average CT for Myocardial Perfusion SPECT/CT Attenuation Correction

被引:0
|
作者
Mok, Greta S. P. [1 ]
Zhang, Duo [1 ]
Ho, Cobie Y. T. [1 ]
机构
[1] Univ Macau, Fac Sci & Technol, Dept Elect & Comp Engn, Macau, Peoples R China
关键词
MISREGISTRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously we proposed interpolated averaged CT (IACT) as a low dose alternate of cine average CT (CACT) for improved PET/CT attenuation correction (AC) in oncology and cardiology applications. This study aims to evaluate the effectiveness of both average CT protocols in myocardial perfusion SPECT/CT. We simulated a patient injected with Tc-99m-sestamibi using the digital 4D Extended Cardiac Torso (XCAT) phantom. We modeled the respiratory motion of 2, 3 and 4 cm with period of 5.9 s. The average attenuation and activity maps represented CACT and static SPECT, while the attenuation maps of end-inspiration and end-expiration represented 2 helical CTs (HCT-in and HCT-ex). The IACT was obtained by averaging the HCT-in, HCT-ex and the interpolated phases between them generated by B-spline method. Sixty noise free and realistic noisy projections with attenuation modeling were generated from RAO to LPO positions using an analytical projector to model a low energy high resolution parallel-hole collimator. Data were reconstructed with different AC maps (CACT, HCTs and IACT) using OS-EM method with up to 200 updates. Polar plots were generated from the short-axis images and 17-segments were drawn on the plots. Relative difference (RD) of the average intensity was computed for each segment using the original phantom as the reference. Slight artifacts can be observed in the reconstructed images and polar plots using the HCTs AC. For motion amplitude = 2 cm, the maximum RD for CACT, IACT, HCT-in and HCT-ex were 0.7%, 2.3%, 6.1% and 8.0% respectively. The RD of the HCTs notably deviated from the phantom in the basal inferolateral and anterolateral regions especially for higher motion amplitudes. Our findings are consistent with our former results of cardiac PET/CT. We conclude that CACT and IACT have the potential to reduce respiratory artifacts and improve quantitation in myocardial perfusion SPECT/CT. The performance of IACT was comparable to CACT with reduced radiation dose.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Initial experience with X-ray ct based attenuation correction in myocardial perfusion spect imaging using a combined spect/ct system
    Daisuke Utsunomiya
    Seiji Tomiguchi
    Shinya Shiraishi
    Koichiro Yamada
    Tsuyoshi Honda
    Koichi Kawanaka
    Akihiro Kojima
    Kazuo Awai
    Yasuyuki Yamashita
    Annals of Nuclear Medicine, 2005, 19 : 485 - 489
  • [32] Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
    Utsunomiya, D
    Tomiguchi, S
    Shiraishi, S
    Yamada, K
    Honda, T
    Kawanaka, K
    Kojima, A
    Awai, K
    Yamashita, Y
    ANNALS OF NUCLEAR MEDICINE, 2005, 19 (06) : 485 - 489
  • [33] Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
    Koichi Okuda
    Kenichi Nakajima
    Masato Yamada
    Hiroshi Wakabayashi
    Hajime Ichikawa
    Hiroyuki Arai
    Shinro Matsuo
    Junichi Taki
    Mitsumasa Hashimoto
    Seigo Kinuya
    Annals of Nuclear Medicine, 2014, 28 : 60 - 68
  • [34] Effect of scattering correction on SPECT/CT myocardial perfusion imaging
    Huang, Kemin
    Feng, Yanlin
    Yu, Fengwen
    Liang, Weitang
    Li, Lin
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [35] IMPORTANCE OF ATTENUATION CORRECTION IN PERFUSION SPECT/CT IN PATIENTS WITH PULMONARY EMBOLISM
    Lysenkov, M.
    Sergienko, V.
    Seriakov, A.
    JOURNAL OF HYPERTENSION, 2015, 33 : E423 - E423
  • [36] Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment
    Blankespoor, SC
    Wu, X
    Kalki, K
    Brown, JK
    Cann, CE
    Hasegawa, BH
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1126 - 1130
  • [37] Dose reduction of CT-based attenuation correction in myocardial perfusion CZT-SPECT using iterative CT reconstruction
    van Dalen, J.
    van Osch, J.
    Mouden, M.
    Timmer, J.
    Ottervanger, J.
    Reiffers, S.
    Knollema, S.
    Jager, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S222 - S222
  • [38] Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment
    Blankespoor, SC
    Wu, X
    Kalki, K
    Brown, JK
    Tang, HR
    Cann, CE
    Hasegawa, BH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2263 - 2274
  • [39] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Sibyll Goetze
    Richard L. Wahl
    Journal of Nuclear Cardiology, 2007, 14
  • [40] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Goetze, Sibyll
    Wahl, Richard L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (02) : 200 - 206