Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT

被引:0
|
作者
Koichi Okuda
Kenichi Nakajima
Masato Yamada
Hiroshi Wakabayashi
Hajime Ichikawa
Hiroyuki Arai
Shinro Matsuo
Junichi Taki
Mitsumasa Hashimoto
Seigo Kinuya
机构
[1] Kanazawa Medical University,Department of Physics
[2] Kanazawa University Hospital,Department of Nuclear Medicine
[3] Kanazawa Advanced Medical Center,Department of Radiology
[4] Toyohashi Municipal Hospital,undefined
[5] Siemens Japan,undefined
来源
关键词
Myocardial perfusion SPECT; Ordered-subset expectation maximization; Attenuation correction; Scatter correction; Depth-dependent resolution recovery;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:60 / 68
页数:8
相关论文
共 50 条
  • [1] Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
    Okuda, Koichi
    Nakajima, Kenichi
    Yamada, Masato
    Wakabayashi, Hiroshi
    Ichikawa, Hajime
    Arai, Hiroyuki
    Matsuo, Shinro
    Taki, Junichi
    Hashimoto, Mitsumasa
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 60 - 68
  • [2] Optimization of iterative reconstruction with attenuation, scatter and resolution corrections in myocardial perfusion SPECT/CT
    Okuda, Koichi
    Nakajima, Kenichi
    Yamada, Masato
    Wakabayashi, Hiroshi
    Ichikawa, Hajime
    Arai, Hiroyuki
    Matsuo, Shinro
    Taki, Junichi
    Kinuya, Seigo
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] Optimization of iterative reconstruction parameters with 3-dimensional resolution recovery, scatter and attenuation correction in 123I-FP-CIT SPECT
    Norikazu Matsutomo
    Akio Nagaki
    Fusae Yamao
    Masayuki Sasaki
    Annals of Nuclear Medicine, 2015, 29 : 636 - 642
  • [4] Optimization of iterative reconstruction parameters with 3-dimensional resolution recovery, scatter and attenuation correction in 123I-FP-CIT SPECT
    Matsutomo, Norikazu
    Nagaki, Akio
    Yamao, Fusae
    Sasaki, Masayuki
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (07) : 636 - 642
  • [5] Multicenter performance evaluation of a new approach to myocardial perfusion SPECT attenuation and scatter correction with resolution recovery
    Bateman, TM
    Johnson, LL
    Tilkemeier, PL
    Iskandrian, AE
    Follansbee, WP
    Heller, GV
    Berman, DS
    Arram, SM
    Garcia, EV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 446A - 446A
  • [6] Impact of attenuation correction, scatter correction and resolution recovery an cardiac SPECT
    Keng, F
    Chang, SM
    Salfity, M
    Verant, MS
    CIRCULATION, 1999, 100 (18) : 312 - 312
  • [7] Dose reduction of CT-based attenuation correction in myocardial perfusion CZT-SPECT using iterative CT reconstruction
    van Dalen, J.
    van Osch, J.
    Mouden, M.
    Timmer, J.
    Ottervanger, J.
    Reiffers, S.
    Knollema, S.
    Jager, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S222 - S222
  • [8] Effects of CT attenuation correction and reconstruction method on myocardial SPECT perfusion imaging.
    Naum, A. G.
    Biermann, M.
    Johnsen, B.
    Husby, J. Aase
    Bach-Gansmo, T.
    Rotevatn, S.
    Nordrehaug, J. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S285 - S286
  • [9] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Duo Zhang
    Bang-Hung Yang
    Nien Yun Wu
    Greta Seng Peng Mok
    Annals of Nuclear Medicine, 2017, 31 : 172 - 180
  • [10] Impact of CT Attenuation Correction in SPECT Myocardial Perfusion Imaging
    Vlachou, F.
    Nikaki, A.
    Gogos, K.
    Tsiakas, E.
    Papoutsani, D.
    Giannis, D.
    Gogou, L.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S317 - S317