Evaluation of a photon-counting hybrid pixel detector array with a synchrotron X-ray source

被引:44
|
作者
Ponchut, C
Visschers, JL
Fornaini, A
Graafsma, H
Maiorino, M
Mettivier, G
Calvet, D
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] CPPM, F-13288 Marseille 9, France
[3] Ist Nazl Fis Nucl, I-80126 Naples, Italy
[4] Univ Naples Federico II, Dipartimento Sci Fisiche, I-80126 Naples, Italy
[5] NIKHEF H, Natl Inst Nucl & High Energy Phys, NL-1009 DB Amsterdam, Netherlands
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2002年 / 484卷 / 1-3期
关键词
hybrid pixel detector; medipix; X-ray imaging; synchrotron; photon-counting;
D O I
10.1016/S0168-9002(01)02029-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photon-counting hybrid pixel detector (Medipix-1) has been characterized using a synchrotron X-ray source. The detector consists of a readout ASIC with 64 x 64 independent photon-counting cells of 170 x 170 mum(2) pitch, bump-bonded to a 300 mum thick silicon sensor, read out by a PCIbus-based electronics, and a graphical user interface (GUI) software. The intensity and the energy tunability of the X-ray source allow characterization of the detector in the time, space, and energy domains. The system can be read out on external trigger at a frame rate of 100 Hz with 3 ms exposure time per frame. The detector response is tested up to more than 7 x 10(5) detected events/pixel/s. The point-spread response shows < 2% crosstalk between neighboring pixels. Fine scanning of the detector surface with a 10 mum beam reveals no loss in sensitivity between adjacent pixels as could result from charge sharing in the silicon sensor. Photons down to 6 keV can be detected after equalization of the thresholds of individual pixels, The obtained results demonstrate the advantages of photon-counting hybrid pixel detectors and particularly of the Medipix-1 chip for a wide range of X-ray imaging applications, including those using synchrotron X-ray beams. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:396 / 406
页数:11
相关论文
共 50 条
  • [31] An Acquisition-Based Approach for High-Fidelity Infilling of Photon-Counting X-ray Detector Pixel Gaps
    Allphin, A. J.
    Nadkarni, R.
    Clark, D. P.
    Badea, C. T.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [32] Silicon-based photon counting X-ray detector for synchrotron applications
    Fant, A
    French, MJ
    Murray, P
    Seller, P
    Manolopoulos, S
    Thomas, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 442 - 447
  • [33] The effects of photon flux on energy spectra and imaging characteristics in a photon-counting x-ray detector
    Cho, H-M
    Kim, H-J
    Choi, Y-N
    Lee, S-W
    Ryu, H-J
    Lee, Y-J
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14): : 4865 - 4879
  • [34] Edge-subtraction X-ray ptychographic imaging with pink beam synchrotron radiation and a single photon-counting detector
    Brun, Francesco
    Di Trapani, Vittorio
    Batey, Darren
    Cipiccia, Silvia
    Rau, Christoph
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [35] Edge-subtraction X-ray ptychographic imaging with pink beam synchrotron radiation and a single photon-counting detector
    Francesco Brun
    Vittorio Di Trapani
    Darren Batey
    Silvia Cipiccia
    Christoph Rau
    Scientific Reports, 10
  • [36] An X-ray fluorescence experimental method for photon-counting detector in computed tomography system
    Wu, Hsiang-Ning
    Chang, Chia-Hao
    Ni, Yu-Ching
    JOURNAL OF INSTRUMENTATION, 2024, 19 (10):
  • [37] Uniformity Correction in Photon-counting X-ray Detector Based on Basis Material Decomposition
    Wang, Xiaolan
    He, Xin
    Taguchi, Katsuyuki
    Patt, Bradley E.
    Wagenaar, Douglas J.
    Frey, Eric C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4168 - +
  • [38] Superfine photon-counting detector for 0.1-100 keV X-ray imaging
    Miyata, E
    Tawa, N
    Mukai, K
    Miki, A
    Koizumi, G
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 56 - 65
  • [39] Identification of amyloid plaques in the brain using an x-ray photon-counting strip detector
    Ghammraoui, Bahaa
    Badano, Aldo
    PLOS ONE, 2020, 15 (02):
  • [40] Characterization of a X-ray pixellated CdTe detector with TIMEPIX photon-counting readout chip
    Ruat, Marie
    Ponchut, Cyril
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4799 - 4803