Evaluation of a photon-counting hybrid pixel detector array with a synchrotron X-ray source

被引:44
|
作者
Ponchut, C
Visschers, JL
Fornaini, A
Graafsma, H
Maiorino, M
Mettivier, G
Calvet, D
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] CPPM, F-13288 Marseille 9, France
[3] Ist Nazl Fis Nucl, I-80126 Naples, Italy
[4] Univ Naples Federico II, Dipartimento Sci Fisiche, I-80126 Naples, Italy
[5] NIKHEF H, Natl Inst Nucl & High Energy Phys, NL-1009 DB Amsterdam, Netherlands
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2002年 / 484卷 / 1-3期
关键词
hybrid pixel detector; medipix; X-ray imaging; synchrotron; photon-counting;
D O I
10.1016/S0168-9002(01)02029-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photon-counting hybrid pixel detector (Medipix-1) has been characterized using a synchrotron X-ray source. The detector consists of a readout ASIC with 64 x 64 independent photon-counting cells of 170 x 170 mum(2) pitch, bump-bonded to a 300 mum thick silicon sensor, read out by a PCIbus-based electronics, and a graphical user interface (GUI) software. The intensity and the energy tunability of the X-ray source allow characterization of the detector in the time, space, and energy domains. The system can be read out on external trigger at a frame rate of 100 Hz with 3 ms exposure time per frame. The detector response is tested up to more than 7 x 10(5) detected events/pixel/s. The point-spread response shows < 2% crosstalk between neighboring pixels. Fine scanning of the detector surface with a 10 mum beam reveals no loss in sensitivity between adjacent pixels as could result from charge sharing in the silicon sensor. Photons down to 6 keV can be detected after equalization of the thresholds of individual pixels, The obtained results demonstrate the advantages of photon-counting hybrid pixel detectors and particularly of the Medipix-1 chip for a wide range of X-ray imaging applications, including those using synchrotron X-ray beams. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:396 / 406
页数:11
相关论文
共 50 条
  • [21] Indirect photon-counting x-ray imaging using CMOS Photon Detector (CPD)
    Nishihara, Toshiyuki
    Baba, Hiroyasu
    Matsumura, Masao
    Kumagai, Oichi
    Izawa, Takashi
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [22] Synchrotron X-ray diffraction experiments with a prototype hybrid pixel detector
    Le Bourlot, C.
    Landois, P.
    Djaziri, S.
    Renault, P. -O.
    Le Bourhis, E.
    Goudeau, P.
    Pinault, M.
    Mayne-L'Hermite, M.
    Bacroix, B.
    Faurie, D.
    Castelnau, O.
    Launois, P.
    Rouziere, S.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2012, 45 : 38 - 47
  • [23] Modeling Spectral Distortions in Energy Resolved Photon-counting X-ray Detector
    Wang, Xiaolan
    Meier, Dirk
    Hugg, James
    Chowdhury, Samir
    Wagenaar, Douglas
    Patt, Bradley
    Frey, Eric
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3054 - 3057
  • [24] X-ray imaging with photon counting hybrid semiconductor pixel detectors
    Manolopoulos, S
    Bates, R
    Campbell, M
    Snoeys, W
    Heijne, E
    Pernigotti, E
    Raine, C
    Smith, K
    Watt, J
    O'Shea, V
    Ludwig, J
    Schwarz, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01): : 38 - 43
  • [25] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [26] X-ray spectroscopy with a photon-counting SiPM-based scintillation detector
    Ceravolo, S.
    Gargiulo, R.
    Paesani, D.
    Russo, A.
    Sarra, I.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [27] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971):
  • [28] Biomedical x-ray imaging with a GaAs photon-counting detector: A comparative study
    Scholz, J.
    Birnbacher, L.
    Petrich, C.
    Riedel, M.
    Heck, L.
    Gkoumas, S.
    Sellerer, T.
    Achterhold, K.
    Herzen, J.
    APL PHOTONICS, 2020, 5 (10)
  • [29] A New High-speed, Photon-counting X-ray Area Detector
    Durst, Roger
    Becker, Bruce
    Diawara, Yacouba
    Khazins, David
    Medved, Sergei
    Sedov, Vladisov
    Smith, Kingsley
    Thorson, Tim
    Wachter, Greg
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C39 - C39
  • [30] Solid-state photon-counting hybrid detector array for high-resolution multi-energy X-ray imaging
    Sia, R.
    Kleinfelder, S.
    Nagarkar, V. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 470 - 473