Distortion Phenomena on Transmission Lines Using Corona Modeling ATP/EMTP

被引:13
|
作者
Anane, Zahira [1 ]
Bayadi, Abdelhafid [1 ]
Huang, Kejie [2 ]
机构
[1] UFAS, Fac Technol, Automat Lab Setif, Dept Elect Engn, Setif, Algeria
[2] Beijing Jiaotong Univ, Sch Elect Engn, Beijing 100044, Peoples R China
关键词
Corona; Q-V curves; ATP/EMTP; Type94; attenuation and distortion; SURGE CORONA; CHARGE;
D O I
10.1109/TDEI.2017.006484
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of corona on the propagation of transient voltages on transmission lines can be studied by modeling the impulse corona discharge, taking into account its physical properties. The technique of corona characteristics (charge-voltage) is more favorable than the propagation delay characteristic which is known to be less accurate and leads to results that are far from reality. In this paper, a mathematical model of corona discharge is integrated into the Alternative Transients Program of the Electro-Magnetic Transients Program software (ATP/EMTP), using the MODELS interface. The attenuation and distortion phenomena on the overhead transmission line caused by corona is modeled and simulated by the implementation of a corona model with the user-defined multi-branch type-94circuit in ATP. Comparison between the computed results and literature experimental investigations gives a good agreement between them.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [41] Transient Analysis of a Distribution Transformer using ATP-EMTP
    Ali, Mujtaba
    Saqib, M. Asghar
    2018 1ST IEEE INTERNATIONAL CONFERENCE ON POWER, ENERGY AND SMART GRID (ICPESG), 2018,
  • [42] Microturbine harmonic impact study using ATP-EMTP
    Kirawanich, P
    O'Connell, RM
    Brownfield, G
    2004 11TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, 2004, : 117 - 122
  • [43] Assessment of corona loss performance on aging transmission lines using PMU measurements
    Gupta, Pradeep Kumar
    Tuttelberg, Kaur
    Kilter, Jako
    ENERGY REPORTS, 2023, 9 : 215 - 219
  • [44] ATP-EMTP Modeling and Performance Test of Different Type Lightning Arrester on 132kv Overhead Transmission Tower
    Islam, Md. Zoyheroul
    Rashed, Md. Rasheduzzaman
    Yusuf, Md. Salah Uddin
    2017 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL INFORMATION AND COMMUNICATION TECHNOLOGY (EICT 2017), 2017,
  • [45] Computation of corona effects in transmission lines using state-space techniques
    Herdem, S
    Mamis, MS
    COMPUTERS & ELECTRICAL ENGINEERING, 2003, 29 (05) : 603 - 611
  • [46] Bewley's Lattice Diagram Implementation by Using ATP/EMTP
    Gonzalez, V.
    Cardenas, R.
    Torres, V.
    Paternina, M.
    IEEE LATIN AMERICA TRANSACTIONS, 2019, 17 (09) : 1458 - 1465
  • [47] Modeling of Battery for EV using EMTP/ATPDraw
    Kim, Jun-Hyeok
    Lee, Soon-Jeong
    Kim, Eung-Sang
    Kim, Seul-Ki
    Kim, Chul-Hwan
    Prikler, Laszlo
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (01) : 98 - 105
  • [48] Modeling and Simulating Transmission Lines Using Fractional Calculus
    Zhang Yanzhu
    Xue Dingyu
    2007 INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, NETWORKING AND MOBILE COMPUTING, VOLS 1-15, 2007, : 3115 - 3118
  • [49] Modeling the influence of Corona Discharge on High-Voltage Surges Propagating along Transmission-Lines using TLM.
    Evans, John L.
    Thomas, David W. P.
    Greedy, Steve
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2015, : 981 - 986
  • [50] Modeling lossy transmission lines using the method of characteristics
    Gupta, R
    Pileggi, LT
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 1996, 43 (07): : 580 - 582