Distortion Phenomena on Transmission Lines Using Corona Modeling ATP/EMTP

被引:13
|
作者
Anane, Zahira [1 ]
Bayadi, Abdelhafid [1 ]
Huang, Kejie [2 ]
机构
[1] UFAS, Fac Technol, Automat Lab Setif, Dept Elect Engn, Setif, Algeria
[2] Beijing Jiaotong Univ, Sch Elect Engn, Beijing 100044, Peoples R China
关键词
Corona; Q-V curves; ATP/EMTP; Type94; attenuation and distortion; SURGE CORONA; CHARGE;
D O I
10.1109/TDEI.2017.006484
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of corona on the propagation of transient voltages on transmission lines can be studied by modeling the impulse corona discharge, taking into account its physical properties. The technique of corona characteristics (charge-voltage) is more favorable than the propagation delay characteristic which is known to be less accurate and leads to results that are far from reality. In this paper, a mathematical model of corona discharge is integrated into the Alternative Transients Program of the Electro-Magnetic Transients Program software (ATP/EMTP), using the MODELS interface. The attenuation and distortion phenomena on the overhead transmission line caused by corona is modeled and simulated by the implementation of a corona model with the user-defined multi-branch type-94circuit in ATP. Comparison between the computed results and literature experimental investigations gives a good agreement between them.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [31] Modeling and Simulation of Thermal Behavior of Zno Surge Arrester Using ATP-EMTP Program
    Anane, Zahira
    Bayadi, Abdeihafid
    Guettaf, Nacereddine
    PROGRAM OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATIC CONTROL, ICEEAC 2024, 2024,
  • [32] Test analysis on effects of dust deposition on corona characteristics transmission lines using corona cage
    Sun, Tao
    Wan, Bao-Quan
    Chen, Yu-Chao
    Fan, Liang
    Guo, Hao-Zhou
    Guan, Qing-Hua
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (12): : 2913 - 2917
  • [33] Dynamic modeling of a hybrid wind/solar/hydro microgrid in EMTP/ATP
    Ye, Lin
    Sun, Hai Bo
    Song, Xu Ri
    Li, Li Cheng
    RENEWABLE ENERGY, 2012, 39 (01) : 96 - 106
  • [34] Modeling and Transient analysis of Overhead Transmission Lines Considering Corona Phenomenon and Skin Effect
    Tabibzadeh, Mehrad
    Mirzaie, Mohammad
    2015 2ND INTERNATIONAL CONFERENCE ON KNOWLEDGE-BASED ENGINEERING AND INNOVATION (KBEI), 2015, : 649 - 654
  • [35] Corona modeling in HVDC transmission lines based on a modified particle-in-cell approach
    Arruda, Carlos K. C.
    Lima, Antonio C. S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 125 : 91 - 99
  • [36] Simulation of Lightning Transients on 110 kV overhead-cable transmission line using ATP-EMTP
    Fekete, Kresimir
    Nikolovski, Srete
    Knezevic, Goran
    Stojkov, Marinko
    Kovac, Zoran
    MELECON 2010: THE 15TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, 2010, : 856 - 861
  • [37] Calculation of Corona losses on HVAC Transmission lines
    Chen Xiong-wen
    Zhao Zhi-bin
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 675 - 680
  • [38] THE SIMULATION OF SURGE CORONA ON TRANSMISSION-LINES
    ALTAI, MA
    ELAYYAN, HSB
    GERMAN, DM
    HADDAD, A
    HARID, N
    WATERS, RT
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 1360 - 1368
  • [40] NONLINEAR PHENOMENA IN SUPERCONDUCTING TRANSMISSION LINES
    COMBET, HA
    MINET, R
    GUENAIS, C
    ANNALES DES TELECOMMUNICATIONS, 1970, 25 (3-4): : 129 - +