Distortion Phenomena on Transmission Lines Using Corona Modeling ATP/EMTP

被引:13
|
作者
Anane, Zahira [1 ]
Bayadi, Abdelhafid [1 ]
Huang, Kejie [2 ]
机构
[1] UFAS, Fac Technol, Automat Lab Setif, Dept Elect Engn, Setif, Algeria
[2] Beijing Jiaotong Univ, Sch Elect Engn, Beijing 100044, Peoples R China
关键词
Corona; Q-V curves; ATP/EMTP; Type94; attenuation and distortion; SURGE CORONA; CHARGE;
D O I
10.1109/TDEI.2017.006484
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of corona on the propagation of transient voltages on transmission lines can be studied by modeling the impulse corona discharge, taking into account its physical properties. The technique of corona characteristics (charge-voltage) is more favorable than the propagation delay characteristic which is known to be less accurate and leads to results that are far from reality. In this paper, a mathematical model of corona discharge is integrated into the Alternative Transients Program of the Electro-Magnetic Transients Program software (ATP/EMTP), using the MODELS interface. The attenuation and distortion phenomena on the overhead transmission line caused by corona is modeled and simulated by the implementation of a corona model with the user-defined multi-branch type-94circuit in ATP. Comparison between the computed results and literature experimental investigations gives a good agreement between them.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [1] Study of the backflashover phenomena in overhead transmission lines using the EMTP
    Teixeira, C. J. Coelho
    Machado e Moura, A.
    2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 1169 - +
  • [2] Simulation of transient processes on overvoltage in electric transmission lines using ATP-EMTP
    Nayir, Ahmet
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2013, 21 (06) : 1553 - 1566
  • [3] Model of corona for an EMTP study of surge propagation along HV transmission lines
    Gallagher, TJ
    Duclurych, IM
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2004, 151 (01) : 61 - 66
  • [4] Studies on the influence of corona on overvoltage surges by simulation using the ATP/EMTP
    Anane, Zahira
    Bayadi, Abdelhafid
    2012 24TH INTERNATIONAL CONFERENCE ON MICROELECTRONICS (ICM), 2012,
  • [5] The use of corona phenomena to measure the voltage of transmission lines
    Youssef, M
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 1051 - 1054
  • [6] Lightning arrester modeling using ATP-EMTP
    Saengsuwan, T
    Thipprasert, W
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C377 - C380
  • [7] Lightning performance analysis of transmission lines using the EMTP
    Martinez, JA
    Castro-Aranda, F
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 295 - 300
  • [8] Modelling of 132kV Overhead Transmission Lines by Using ATP/EMTP for Shielding Failure Pattern Recognition
    Zawani, Nur
    Junainah
    Imran
    Faizuhar, Mohd
    MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING & TECHNOLOGY 2012 (MUCET 2012), 2013, 53 : 278 - 287
  • [9] Lightning performance analysis of overhead transmission lines using the EMTP
    Martinez, JA
    Castro-Aranda, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 2200 - 2210
  • [10] Simulation of Power System Dynamic Phenomena in ATP/EMTP
    Reyes, R. A.
    Guardado, J. L.
    2014 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2014,