A Decade of Outcomes and Predictors of Sac Enlargement after Endovascular Abdominal Aortic Aneurysm Repair Using Zenith Endografts in a Japanese Population

被引:21
|
作者
Iwakoshi, Shinichi [1 ]
Ichihashi, Shigeo [1 ]
Higashiura, Wataru [1 ]
Itoh, Hirofumi [1 ]
Sakaguchi, Shoji [1 ]
Tabayashi, Nobuoki [2 ]
Uchida, Hideo [1 ]
Kichikawa, Kimihiko [1 ]
机构
[1] Nara Med Univ, Dept Radiol, Kashihara, Nara 6348521, Japan
[2] Nara Med Univ, Dept Thorac & Cardiovasc Surg, Kashihara, Nara 6348521, Japan
关键词
NECK ANATOMY; STENT-GRAFT; EXPERIENCE; EUROSTAR; DIAMETER; COMPLICATIONS; HOSTILE;
D O I
10.1016/j.jvir.2014.01.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present 10-year outcomes and risk factors for sac enlargement after endovascular aneurysm repair (EVAR) using the Zenith, AAA Endovascular Graft (Cook, Inc, Bloomington, Indiana) in a Japanese population. Material and Methods: During the period 1999-2011, 127 patients underwent elective EVAR using Zenith endografts at a single institution. A retrospective investigation looked at initial rates of technical success and complications, 10-year rate of freedom from all-cause and aneurysm-related mortality, freedom from secondary intervention and sac,enlargement, and risk factors for second intervention and sac enlargement. Results: The median age of the patients was 78 years, and the median follow-tip time was 43 months. The initial technical success rate was 98.4% (123 of 127 patients). Major adverse events occurred in 7 of 127 (5.5%) patients. Rates of freedom from all-cause and aneurysm-related mortality at 1, 3, 5, mid 10 years were 95%, 87%, 77%, and 39% (all-cause mortality) and 100%, 100%; 99%, and 93% (aneurysm-related mortality). Rates of freedom from secondary intervention at 1, 3 5, and 10 years were 97%, 91%, 88%, and 70%. Rates of primary freedom from sac enlargement at 1, 3, 5, and 10 years were 99%, 87%, 75%, and 67%. Multivariate analysis revealed aneurysm sac diameter as an independent risk factor for a secondary intervention. Preoperative sac diameter combined with an angulated short (AS) proximal neck was a risk factor for sac enlargement. Conclusions: The 10-year results of EVAR using Zenith endografts in a Japanese population were comparable to results from Western countries. Larger aneurysms and AS neck were predictors of sac enlargement after EVAR.
引用
收藏
页码:694 / 701
页数:8
相关论文
共 50 条
  • [31] CT after Endovascular Repair of Abdominal Aortic Aneurysms: Diagnostic Accuracy of Diameter Measurements for the Detection of Aneurysm Sac Enlargement
    Schnitzbauer, Michael
    Guentner, Oliver
    Wohlgemuth, Walter A.
    Zeman, Florian
    Haimerl, Michael
    Stroszczynski, Christian
    Mueller-Wine, Rene
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (02) : 178 - 187
  • [32] Preoperative Relative Abdominal Aortic Aneurysm Thrombus Burden Predicts Endoleak and Sac Enlargement After Endovascular Anerysm Repair
    Sadek, Mikel
    Dexter, David J.
    Rockman, Caron B.
    Hoang, Han
    Mussa, Firas F.
    Cayne, Neal S.
    Jacobowitz, Glen R.
    Veith, Frank J.
    Adelman, Mark A.
    Maldonado, Thomas S.
    ANNALS OF VASCULAR SURGERY, 2013, 27 (08) : 1036 - 1041
  • [33] Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurement
    Ellozy, SH
    Carroccio, A
    Lookstein, RA
    Jacobs, TS
    Addis, MD
    Teodorescu, VJ
    Marin, ML
    JOURNAL OF VASCULAR SURGERY, 2006, 43 (01) : 2 - 6
  • [34] Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: A comparison of AneuRx and Zenith endografts - Discussion
    Lee, WA
    Tonnessen, BH
    Farber, M
    Arko, F
    Money, SR
    JOURNAL OF VASCULAR SURGERY, 2005, 42 (03) : 400 - 401
  • [35] Hybrid endografts combinations for the treatment of endoleak in endovascular abdominal aortic aneurysm repair
    Georgiadis, George S.
    Trellopoulos, George
    Antoniou, George A.
    Georgakarakos, Efstratios I.
    Nikolopoulos, Evagelos S.
    Iatrou, Christos
    Lazarides, Miltos K.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2013, 36 (01): : 28 - 38
  • [36] Endovascular Repair of a Common Iliac Artery Aneurysm Using the Cook Zenith Abdominal Aortic Aneurysm Endovascular Graft Converter
    Crago, Aimee M.
    Singh, Niten
    Deaton, David H.
    Neville, Richard F.
    Laredo, James
    VASCULAR AND ENDOVASCULAR SURGERY, 2008, 42 (01) : 54 - 57
  • [37] Outcomes of secondary interventions after abdominal aortic aneurysm endovascular repair
    Becquemin, JP
    Kelley, L
    Zubilewicz, T
    Desgranges, P
    Lapeyre, M
    Kobeiter, H
    JOURNAL OF VASCULAR SURGERY, 2004, 39 (02) : 298 - 304
  • [38] Modular component separation and reperfusion of abdominal aortic aneurysm sac after endovascular repair of the abdominal aortic aneurysm: A case report
    Maleux, G
    Rousseau, H
    Otal, P
    Colombier, D
    Glock, Y
    Joffre, F
    JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) : 349 - 352
  • [39] Device specific outcomes after endovascular abdominal aortic aneurysm repair
    Pulli, R.
    Dorigo, W.
    Marek, J.
    Di Mare, M.
    Troisi, N.
    Fargion, A.
    Calistri, M.
    Chiti, E.
    Matticari, S.
    Innocenti, A. Alessi
    Pratesi, G.
    Pratesi, C.
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 16 (01): : 9 - 16
  • [40] Hybrid endografts combinations for the treatment of endoleak in endovascular abdominal aortic aneurysm repair
    Department of Vascular Surgery, University General Hospital of Alexandroupolis, Demokritus University of Thrace, Alexandroupolis, Greece
    不详
    不详
    Georgiadis, G. S. (ggeorgia@med.duth.gr), 1600, Wichtig Publishing Srl (36):