Energy-tunable transmission x-ray microscope for differential contrast imaging with near 60 nm resolution tomography

被引:83
|
作者
Yin, Gung-Chian
Tang, Mau-Tsu
Song, Yen-Fang
Chen, Fu-Rong
Liang, Keng S.
Duewer, Frederick W.
Yun, Wenbing
Ko, Chen-Hao
Shieh, Han-Ping D.
机构
[1] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
[2] Natl Chiao Tung Univ, Dept Photon, Hsinchu 300, Taiwan
[3] Natl Chiao Tung Univ, Display Inst, Hsinchu 300, Taiwan
[4] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
[5] Xradia Inc, Concord, CA 94520 USA
[6] Yuan Ze Univ, Dept Elect Engn, Chungli 320, Taiwan
关键词
D O I
10.1063/1.2211300
中图分类号
O59 [应用物理学];
学科分类号
摘要
An energy-tunable transmission hard x-ray microscope with close to 60 nm spatial resolution in three dimensions (3D) has been developed. With a cone beam illumination, a zone plate of 50 nm outmost zone width, a stable mechanical design, and software feedback, we obtained tomographic data sets that are close to 60 nm spatial resolution. Meanwhile, the element specific imaging was also obtained by a differential absorption contrast technique used below and above the absorption of the element. Examples of advanced intergraded circuit devices are used to demonstrate the element selectivity and spatial resolution in 3D of the microscope.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] X-ray phase tomography with a Talbot interferometer in combination with an X-ray imaging microscope
    Momose, Atsushi
    Takeda, Yoshihiro
    Yashiro, Wataru
    Takeuchi, Akihisa
    Suzuki, Yoshio
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [22] Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue
    Jakubek, Jan
    Granja, Carlos
    Dammer, Jiri
    Hanus, Robert
    Holy, Tomas
    Pospisil, Stanislav
    Tykva, Richard
    Uher, Josef
    Vykydal, Zdenek
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 69 - 72
  • [23] A hard x-ray KB-FZP microscope for tomography with sub-100-nm resolution
    Rau, C.
    Crecea, V.
    Richter, C. -P.
    Peterson, K. M.
    Jemian, P. R.
    Neuhaeusler, U.
    Schneider, G.
    Yu, X.
    Braun, P. V.
    Chiang, T. -C.
    Robinson, I. K.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [24] Contrast and resolution in imaging with a microfocus x-ray source
    Pogany, A
    Gao, D
    Wilkins, SW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07): : 2774 - 2782
  • [25] A full field transmission X-ray microscope as a tool for high-resolution magnetic imaging
    Denbeaux, G
    Fischer, P
    Kusinski, G
    Le Gros, M
    Pearson, A
    Attwood, D
    IEEE TRANSACTIONS ON MAGNETICS, 2001, 37 (04) : 2764 - 2766
  • [26] Phase-Contrast Imaging and Tomography at 60 keV using a Conventional X-ray Tube
    Donath, T.
    Pfeiffer, F.
    Bunk, O.
    Groot, W.
    Bednarzik, M.
    Gruenzweig, C.
    Hempel, E.
    Popescu, S.
    Hoheisel, M.
    David, C.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [27] Quantitative phase imaging with a scanning transmission x-ray microscope
    de Jonge, M. D.
    Homberger, B.
    Holzner, C.
    Legnini, D.
    Paterson, D.
    McNulty, I.
    Jacobsen, C.
    Vogt, S.
    PHYSICAL REVIEW LETTERS, 2008, 100 (16)
  • [28] Contrast-to-noise in X-ray differential phase contrast imaging
    Engel, Klaus J.
    Geller, D.
    Koehler, T.
    Martens, G.
    Schusser, S.
    Vogtmeier, G.
    Roessl, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S202 - S207
  • [29] Helical x-ray differential phase contrast computed tomography
    Qi, Zhihua
    Theriault-Lauzier, Pascal
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [30] Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: II. Tomography
    Wang, Y
    Jacobsen, C
    Maser, J
    Osanna, A
    JOURNAL OF MICROSCOPY-OXFORD, 2000, 197 : 80 - 93