Quantitative Insulin Analysis Using Liquid Chromatography-Tandem Mass Spectrometry in a High-Throughput Clinical Laboratory

被引:79
|
作者
Chen, Zhaohui [1 ]
Caulfield, Michael P. [1 ]
McPhaul, Michael J. [1 ]
Reitz, Richard E. [1 ]
Taylor, Steven W. [1 ]
Clarke, Nigel J. [1 ]
机构
[1] Quest Diagnost Nichols Inst, San Juan Capistrano, CA 92675 USA
关键词
BASAL-STATE HYPERINSULINEMIA; HEALTHY NORMOGLYCEMIC ADULTS; ISOTOPE-DILUTION ASSAY; IMMUNOAFFINITY PURIFICATION; SYNTHETIC ANALOGS; STANDARDIZATION; IMMUNOASSAYS;
D O I
10.1373/clinchem.2012.199794
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Circulating insulin concentrations reflect the amount of endogenous insulin produced by the pancreas and can be monitored to check for insulin resistance. Insulin is commonly measured using immunochemiluminometric assays (ICMA). Unfortunately, differing crossreactivities of the various ICMA antibodies have led to variability in assay results. In contrast, liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based approaches can provide a highly specific alternative to immunoassays. METHODS: Insulin was extracted from patient serum and reduced to liberate the insulin B chain. Subsequent resolution of the peptide was achieved by LC coupled to triple-quadrupole MS. Selected-reaction monitoring of B-chain transitions was used for quantification. Recombinant human insulin was used as a calibrator and was compared against the National Institute for Biological Standards and Control (NIBSC) reference standard. Bovine insulin and a stable isotopic-labeled (C-13/N-15) human insulin B chain were used and compared as internal standards. RESULTS: The LC-MS/MS assay described herein has been validated according to CLIA guidelines with a limit of detection of 1.8 mu IU/mL (10.8 pmol/L) and a limit of quantitation of 3 mu IU/mL (18.0 pmol/L). A correlation between the LC-MS/MS assay and a US Food and Drug Administration-approved ICMA was completed for patient samples and the resulting Deming regression revealed good agreement. A reference interval for the assay was established. CONCLUSIONS: A simple, high-throughput, quantitative LC-MS/MS insulin assay traceable to the NIBSC standard has been successfully developed and validated. (C) 2013 American Association for Clinical Chemistry
引用
收藏
页码:1349 / 1356
页数:8
相关论文
共 50 条
  • [41] Improving quantitative precision and throughput by reducing calibrator use in liquid chromatography-tandem mass spectrometry
    Rule, Geoffrey S.
    Rockwood, Alan L.
    [J]. ANALYTICA CHIMICA ACTA, 2016, 919 : 55 - 61
  • [42] Quantitative Analysis of Phytosterols in Edible Oils Using APCI Liquid Chromatography-Tandem Mass Spectrometry
    Mo, Shunyan
    Dong, Linlin
    Hurst, W. Jeffrey
    van Breemen, Richard B.
    [J]. LIPIDS, 2013, 48 (09) : 949 - 956
  • [43] High Throughput Residue Analysis of Indaziflam and its Metabolites in Palm Oil Using Liquid Chromatography-Tandem Mass Spectrometry
    Halim, Norizah
    Kuntom, Ainie
    Shinde, Raviraj
    Banerjee, Kaushik
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (05) : 1237 - 1242
  • [44] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [45] Liquid chromatography tandem mass spectrometry in the clinical laboratory
    Adaway, Joanne E.
    Keevil, Brian G.
    Owen, Laura J.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (01) : 18 - 38
  • [46] Analysis of Desomorphine in Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    Winborn, Jessica
    Kerrigan, Sarah
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (05) : 340 - 345
  • [47] Analysis of pharmaceuticals in fish using liquid chromatography-tandem mass spectrometry
    Ramirez, Alejandro J.
    Mottaleb, Mohammad A.
    Brooks, Bryan W.
    Chambliss, C. Kevin
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (08) : 3155 - 3163
  • [48] Development of a high-throughput liquid chromatography-tandem mass spectrometry platform for the determination of intact natriuretic peptides in human plasma
    Lenzi, Alessio
    De Cristofaro, Mariano
    Biagini, Denise
    Ghimenti, Silvia
    Armenia, Silvia
    Pugliese, Nicola R.
    Masi, Stefano
    Di Francesco, Fabio
    Lomonaco, Tommaso
    [J]. Talanta, 2024, 275
  • [49] A high-throughput liquid chromatography-tandem mass spectrometry method for simultaneous determination of direct oral anticoagulants in human plasma
    Zidekova, Nela
    Prso, Kristian
    Brisudova, Kristina
    Babalova, Lucia
    Bolek, Tomas
    Sivak, Stefan
    Kurca, Egon
    Mokry, Juraj
    Samos, Matej
    Nosal, Vladimir
    Kertys, Martin
    [J]. JOURNAL OF SEPARATION SCIENCE, 2023, 46 (13)
  • [50] Extractionless and sensitive method for high-throughput quantitation of cetirizine in human plasma samples by liquid chromatography-tandem mass spectrometry
    de Jager, AD
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 113 - 118