A high-throughput liquid chromatography-tandem mass spectrometry method for simultaneous determination of direct oral anticoagulants in human plasma

被引:3
|
作者
Zidekova, Nela [1 ]
Prso, Kristian [1 ]
Brisudova, Kristina [2 ]
Babalova, Lucia [3 ]
Bolek, Tomas [2 ]
Sivak, Stefan [3 ]
Kurca, Egon [3 ]
Mokry, Juraj [1 ]
Samos, Matej [2 ]
Nosal, Vladimir [3 ]
Kertys, Martin [1 ,4 ]
机构
[1] Comenius Univ, Jessenius Fac Med Martin, Dept Pharmacol, Bratislava, Slovakia
[2] Comenius Univ, Jessenius Fac Med Martin, Dept Internal Med 1, Martin, Slovakia
[3] Comenius Univ, Jessenius Fac Med Martin, Dept Neurol, Martin, Slovakia
[4] Comenius Univ, Jessenius Fac Med Martin, Biomed Ctr Martin, Bratislava, Slovakia
关键词
direct oral anticoagulants; human plasma; tandem mass spectrometry; therapeutic drug monitoring; UPLC-MS/MS; RIVAROXABAN; APIXABAN; DABIGATRAN; QUANTIFICATION; EDOXABAN;
D O I
10.1002/jssc.202300084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct oral anticoagulants are widely used in many indications to prevent thromboembolic events. Routine therapeutic monitoring is not required; however, there is increasing evidence suggesting the benefit of plasma level measurement in some situations. In addition, laboratory monitoring might help improve patient and drug non-compliance and thus individualize therapy. In the present study, we developed a sensitive and high throughput ultra-high-performance liquid chromatography-tandem mass spectrometry method for simultaneous quantification of apixaban, dabigatran, edoxaban, and rivaroxaban in human plasma. A one-step extraction procedure in 96-well formate for phospholipid and protein removal was used for sample pre-treatment, and analytes were separated using gradient elution over 4.2 min. Analytes were detected on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode. The method was validated according to the European Medicine Agency guideline for the selectivity, linearity, and lower limit of detection, precision and accuracy, matrix effects, extraction recovery, carryover, dilution integrity, and stability over a concentration range of 3.0-1000 ng/ml for all analytes. The validated method was applied to real clinical samples of patients treated with one of the drugs. Therefore, we can conclude that our method is suitable for therapeutic drug monitoring of direct oral anticoagulants.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [2] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [3] A simple high-throughput method for the determination of plasma methylmalonic acid by liquid chromatography-tandem mass spectrometry
    Blom, Henk J.
    van Rooij, Arno
    Hogeveen, Marije
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) : 645 - 650
  • [4] High-throughput plasma docetaxel quantification by liquid chromatography-tandem mass spectrometry
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Frustaci, Sergio
    Toffoli, Giuseppe
    [J]. CLINICA CHIMICA ACTA, 2011, 412 (3-4) : 358 - 364
  • [5] Extractionless and sensitive method for high-throughput quantitation of cetirizine in human plasma samples by liquid chromatography-tandem mass spectrometry
    de Jager, AD
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 113 - 118
  • [6] Determination of tandospirone in human plasma by a liquid chromatography-tandem mass spectrometry method
    Jin, Fengdan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2881 - 2887
  • [7] Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Trimetazidine in Human Plasma
    Zou, Jianjun
    Dai, Li
    Wang, Guang Ji
    Zhu, Yubing
    Fan, Hongwei
    Xiao, Da Wei
    [J]. ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2008, 58 (09): : 429 - 434
  • [8] Simultaneous determination of metformin and glipizide in human plasma by liquid chromatography-tandem mass spectrometry
    Ding, Cun-Gang
    Zhou, Zhen
    Ge, Qing-Hua
    Zhi, Xiao-Jin
    Ma, Li-Li
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 132 - 138
  • [9] Simultaneous determination of hypericin and hyperforin in human plasma with liquid chromatography-tandem mass spectrometry
    Riedel, KD
    Rieger, K
    Martin-Facklam, M
    Mikus, G
    Haefeli, WE
    Burhenne, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 27 - 33
  • [10] Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma
    Chen, XY
    Huang, J
    Kong, Z
    Zhong, DF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 263 - 269