Proposal and techno-economic analysis of a novel system for waste heat recovery and water saving in coal-fired power plants: A case study

被引:26
|
作者
Tan, Houzhang [1 ]
Cao, Ruijie [1 ]
Wang, Shunsen [1 ]
Wang, Yibin [1 ]
Deng, Shuanghui [1 ]
Duic, Neven [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian, Shaanxi, Peoples R China
[2] Univ Zagreb, Fac Mech Engn & Naval Architecture, Zagreb, Croatia
关键词
Waste heat recovery; Coal consumption; Water saving; Coal-fired power plant; Flue gas; Techno-economic analysis; PHASE-TRANSITION AGGLOMERATOR; FLUE-GAS; LATENT-HEAT; CYCLE; PUMP;
D O I
10.1016/j.jclepro.2020.124372
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel system, which systematically recover waste heat and reduce water consumption in coal-fired power plants, is proposed in this paper. Critical components of the system are two fluorine plastic heat exchangers (FHEs) located downstream and upstream of WFGD scrubber, and condensate and feed water extracted from the regenerative heater (RH) act as coolants, respectively. All recovered heat is utilized directly with no heat pump required. A thermodynamic model, where the steam/water cycle is coupled with the exhaust flue gas flow, is built to assess the performance of the system, and the economic analysis is involved to further explore the feasibility. The simulation is conducted based on parameters of a 1000 MW coal-fired power unit in operation, while coal and water saving rates, payback period, and net present value (NPV) are used as criteria in the assessment. The results show that the system can significantly reduce coal and water consumption of the reference power unit. The temperature of condensate and feed water extraction determines the techno-economic performance of the low-and high-temperature FHEs (LFHE and HFHE), respectively. Lower condensate temperature and higher feed water extraction temperature are more beneficial. Compared with the case of only LFHE, integrating HFHE into the system will increase the overall coal and water saving rates obviously, although the performance of LFHE is weakened. All layouts of the system presented in this paper are techno-economically feasible, and the layout in Case 4 where HFHE is installed in parallel with RH6 is the optimal one. Coal and water saving rates, and NPV of the optimal layout are up to 4.11 g/kWh, 95 t/h, and 102,739,000 RMB, respectively, while the payback period is less than 4 y. Application of this system is beneficial to mitigating the environmental problems caused by coal-fired power generation. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Exergy-based analysis combined with LCA for waste heat recovery in coal-fired CHP plants
    Zhang, Qi
    Gao, Jintong
    Wang, Yujie
    Wang, Lin
    Yu, Zaihai
    Song, Dayong
    ENERGY, 2019, 169 : 247 - 262
  • [42] Industrial test and techno-economic analysis of CO2 capture in Huaneng Beijing coal-fired power station
    Huang Bin
    Xu Shisen
    Gao Shiwang
    Liu Lianbo
    Tao Jiye
    Niu Hongwei
    Cai Ming
    Cheng Jian
    APPLIED ENERGY, 2010, 87 (11) : 3347 - 3354
  • [43] A new conceptual cold-end design of boilers for coal-fired power plants with waste heat recovery
    Yang, Yongping
    Xu, Cheng
    Xu, Gang
    Han, Yu
    Fang, Yaxiong
    Zhang, Dongke
    ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 137 - 146
  • [44] Energy saving potential and system energy saving model of flue gas waste heat in coal-fired power plant boiler
    Duan A.
    Huang Y.
    Duan Y.
    Duan, Aixia (dax0307@163.com), 1600, Italian Association of Chemical Engineering - AIDIC (62): : 565 - 570
  • [45] New integration mechanism of solar energy into 300 MW coal-fired power plant: Performance and techno-economic analysis
    Shagdar, Enkhbayar
    Shuai, Yong
    Lougou, Bachirou Guene
    Mustafa, Azeem
    Choidorj, Dashpuntsag
    Tan, Heping
    ENERGY, 2022, 238
  • [46] Repurposing South Africa's Retiring Coal-Fired Power Stations for Renewable Energy Generation: A Techno-Economic Analysis
    Nogaya, Gugulethu
    Nwulu, Nnamdi, I
    Gbadamosi, Saheed Lekan
    ENERGIES, 2022, 15 (15)
  • [47] CO2 Emissions Reduction From Coal-Fired Power Generation: A Techno-Economic Comparison
    Tola, Vittorio
    Cau, Giorgio
    Ferrara, Francesca
    Pettinau, Alberto
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2016, 138 (06):
  • [48] Techno-economic assessments of oxy-fuel technology for South African coal-fired power stations
    Oboirien, B. O.
    North, B. C.
    Kleyn, T.
    ENERGY, 2014, 66 : 550 - 555
  • [49] Thermodynamic analysis of a low-pressure economizer based waste heat recovery system for a coal-fired power plant
    Wang, Chaojun
    He, Boshu
    Yan, Linbo
    Pei, Xiaohui
    Chen, Shinan
    ENERGY, 2014, 65 : 80 - 90
  • [50] Techno-economic analysis of a coal-fired CHP based combined heating system with gas-fired boilers for peak load compensation
    Wang, Hai-Chao
    Jiao, Wen-Ling
    Lahdelma, Risto
    Zou, Ping-Hua
    ENERGY POLICY, 2011, 39 (12) : 7950 - 7962