Proposal and techno-economic analysis of a novel system for waste heat recovery and water saving in coal-fired power plants: A case study

被引:26
|
作者
Tan, Houzhang [1 ]
Cao, Ruijie [1 ]
Wang, Shunsen [1 ]
Wang, Yibin [1 ]
Deng, Shuanghui [1 ]
Duic, Neven [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian, Shaanxi, Peoples R China
[2] Univ Zagreb, Fac Mech Engn & Naval Architecture, Zagreb, Croatia
关键词
Waste heat recovery; Coal consumption; Water saving; Coal-fired power plant; Flue gas; Techno-economic analysis; PHASE-TRANSITION AGGLOMERATOR; FLUE-GAS; LATENT-HEAT; CYCLE; PUMP;
D O I
10.1016/j.jclepro.2020.124372
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel system, which systematically recover waste heat and reduce water consumption in coal-fired power plants, is proposed in this paper. Critical components of the system are two fluorine plastic heat exchangers (FHEs) located downstream and upstream of WFGD scrubber, and condensate and feed water extracted from the regenerative heater (RH) act as coolants, respectively. All recovered heat is utilized directly with no heat pump required. A thermodynamic model, where the steam/water cycle is coupled with the exhaust flue gas flow, is built to assess the performance of the system, and the economic analysis is involved to further explore the feasibility. The simulation is conducted based on parameters of a 1000 MW coal-fired power unit in operation, while coal and water saving rates, payback period, and net present value (NPV) are used as criteria in the assessment. The results show that the system can significantly reduce coal and water consumption of the reference power unit. The temperature of condensate and feed water extraction determines the techno-economic performance of the low-and high-temperature FHEs (LFHE and HFHE), respectively. Lower condensate temperature and higher feed water extraction temperature are more beneficial. Compared with the case of only LFHE, integrating HFHE into the system will increase the overall coal and water saving rates obviously, although the performance of LFHE is weakened. All layouts of the system presented in this paper are techno-economically feasible, and the layout in Case 4 where HFHE is installed in parallel with RH6 is the optimal one. Coal and water saving rates, and NPV of the optimal layout are up to 4.11 g/kWh, 95 t/h, and 102,739,000 RMB, respectively, while the payback period is less than 4 y. Application of this system is beneficial to mitigating the environmental problems caused by coal-fired power generation. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Techno-economic performance of wind and coal-fired power with CCS joint planning
    Huang Xianzheng
    Sun Yong
    Xu Zhaofeng
    Xue Yali
    Wang Zhe
    Cai Hongyi
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 6677 - 6684
  • [22] Techno-economic analysis of supercritical carbon dioxide cycle integrated with coal-fired power plant
    Thanganadar, Dhinesh
    Asfand, Faisal
    Patchigolla, Kumar
    Turner, Peter
    ENERGY CONVERSION AND MANAGEMENT, 2021, 242
  • [23] Techno-economic analysis of thermoelectrics for waste heat recovery
    Anderson, Kris
    Brandon, Nigel
    ENERGY SOURCES PART B-ECONOMICS PLANNING AND POLICY, 2019, 14 (04) : 147 - 157
  • [24] Advanced power cycles for coal-fired power plants based on calcium looping combustion: A techno-economic feasibility assessment
    Michalski, Sebastian
    Hanak, Dawid P.
    Manovic, Vasilije
    APPLIED ENERGY, 2020, 269
  • [25] Performance analysis of ceramic membrane tube modules for water and heat recovery in coal-fired power plants
    Jia, Chenhui
    Liu, Pei
    Li, Zheng
    JOURNAL OF CLEANER PRODUCTION, 2021, 306
  • [26] Techno-economic evaluation of chemical looping-based coal-fired power plant
    Zou, Xixian
    Zhao, Haibo
    Zheng, Chuguang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (35): : 6286 - 6295
  • [27] Techno-economic analysis of oxy-combustion coal-fired power plant with cryogenic oxygen storage
    Hanak, Dawid P.
    Powell, Dante
    Manovic, Vasilije
    APPLIED ENERGY, 2017, 191 : 193 - 203
  • [28] A novel design of low-grade waste heat utilization for coal-fired power plants with sulfuric acid recovery
    Ouyang, Tiancheng
    Xu, Jisong
    Su, Zixiang
    Zhao, Zhongkai
    Huang, Guicong
    Mo, Chunlan
    ENERGY CONVERSION AND MANAGEMENT, 2021, 227
  • [29] N2 selective membrane based hybrid cryogenic carbon capture process for coal-fired power plants: A techno-economic case study
    Sreenath, S.
    Sam, Ashish Alex
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2025, 213 : 25 - 41
  • [30] Performance analysis of a novel biomass gasification system coupled to a coal-fired power plant based on heat and water recovery
    Chen, Xi
    Zhang, Chuxuan
    Chen, Xuanlong
    Peng, Zhengkang
    Gao, Huanting
    Gong, Xun
    ENERGY CONVERSION AND MANAGEMENT, 2024, 299