Electrochemiluminescence biosensor for folate receptor based on terminal protection of small-molecule-linked DNA

被引:33
|
作者
Li, Ruibao [1 ,2 ]
Wang, Chunmei [1 ,2 ]
Hu, Yuhua [1 ,2 ]
Zheng, Ou [1 ,2 ]
Guo, Longhua [1 ,2 ]
Lin, Zhenyu [1 ,2 ]
Qiu, Bin [1 ,2 ]
Chen, Guonan [1 ,2 ]
机构
[1] Fuzhou Univ, Dept Chem, MOE Key Lab Anal & Detect Food Safety, Fuzhou 350108, Fujian, Peoples R China
[2] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Fuzhou 350108, Fujian, Peoples R China
来源
关键词
Electrochemiluminescence; Biosensor; Terminal protection; Folate receptor; ELECTROGENERATED CHEMILUMINESCENCE; ELECTROCHEMICAL DETECTION; BINDING; PROTEIN; COMPLEX;
D O I
10.1016/j.bios.2014.02.066
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Owning to the characteristics such as high sensitivity and simplicity of apparatus, electrochemiluminescence (ECL) has become a powerful analytical technique and has been widely used. Ru(phen)(3)(2+) can be intercalated into the grooves of dsDNA and act as an ECL probe efficiently, which has been applied to develop a sensitive ECL biosensor for folate receptor in this study. One ssDNA with a thiol group at its 3' termini had been modified on the Au electrode first, and the other ssDNA with folic acid at its 3' termini hybridized with the former one being modified on the electrode surface to form a dsDNA. In the absence of folate receptor, the 3'-terminus in the dsDNA region can be specificity hydrolyzed into mononucleotides by ExoIII and on dsDNA presents on the electrode surface, leading to the lower of ECL intensity detected. However, in the presence of the target (folate receptor), ExoIII failed to hydrolyze the dsDNA since the one 3'-terminus had been protected by the target and the other protected by the Au electrode, resulting in the enhancement of ECL intensity. The enhanced ECL intensity has a linear relationship with the logarithm of folate receptor concentration in the range of 0.66 nmol/L and 26.31 nmol/L with a detection limit of 0.1204 nmol/L. The proposed biosensor had been applied to detect HeLa cells concentration with satisfied results. (c) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [31] Protein Detection Based on Small Molecule-Linked DNA
    Cao, Ya
    Zhu, Sha
    Yu, Jiacui
    Zhu, Xuejun
    Yin, Yongmei
    Li, Genxi
    ANALYTICAL CHEMISTRY, 2012, 84 (10) : 4314 - 4320
  • [32] Fluorescence biosensor for folate receptors in cancer cells based on terminal protection and hyperbranched rolling circle amplification
    Li, Dawei
    Ma, Yuanzheng
    Zhang, Ying
    Lin, Zhenyu
    ANALYTICAL METHODS, 2016, 8 (32) : 6231 - 6235
  • [33] Electrochemiluminescence biosensor for the assay of small molecule and protein based on bifunctional aptamer and chemiluminescent functionalized gold nanoparticles
    Chai, Ying
    Tian, Dayong
    Cui, Hua
    ANALYTICA CHIMICA ACTA, 2012, 715 : 86 - 92
  • [34] Detection of biotin-streptavidin interactions via terminal protection of small molecule linked DNA and the formation of fluorescent DNA-templated silver nanoclusters
    Yue He
    Bining Jiao
    Microchimica Acta, 2016, 183 : 3183 - 3189
  • [35] Detection of biotin-streptavidin interactions via terminal protection of small molecule linked DNA and the formation of fluorescent DNA-templated silver nanoclusters
    He, Yue
    Jiao, Bining
    MICROCHIMICA ACTA, 2016, 183 (12) : 3183 - 3189
  • [36] Simple and convenient G-quadruplex-based fluorescent assay of biotin-streptavidin interaction via terminal protection of small molecule-linked DNA
    Yue He
    Bining Jiao
    Microchimica Acta, 2016, 183 : 3303 - 3309
  • [37] Simple and convenient G-quadruplex-based fluorescent assay of biotin-streptavidin interaction via terminal protection of small molecule-linked DNA
    He, Yue
    Jiao, Bining
    MICROCHIMICA ACTA, 2016, 183 (12) : 3303 - 3309
  • [38] Terminal protection of a small molecule-linked loop DNA probe for turn-on label-free fluorescence detection of proteins
    Chen, Xuexu
    Lin, Chunshui
    Chen, Yiying
    Luo, Feng
    Wang, Yiru
    Chen, Xi
    BIOSENSORS & BIOELECTRONICS, 2016, 83 : 97 - 101
  • [39] Coupling of background reduction with rolling circle amplification for highly sensitive protein detection via terminal protection of small molecule-linked DNA
    Wang, Qiong
    Jiang, Bingying
    Xie, Jiaqing
    Xiang, Yun
    Yuan, Ruo
    Chai, Yaqin
    ANALYST, 2013, 138 (19) : 5751 - 5756
  • [40] A WS2 nanosheet-based nanosensor for the ultrasensitive detection of small molecule-protein interaction via terminal protection of small molecule-linked DNA and Nt.BstNBI-assisted recycling amplification
    Chen, Jia
    Gao, Cunji
    Mallik, Abul K.
    Qiu, Hongdeng
    JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (30) : 5161 - 5166