Electrochemiluminescence biosensor for folate receptor based on terminal protection of small-molecule-linked DNA

被引:33
|
作者
Li, Ruibao [1 ,2 ]
Wang, Chunmei [1 ,2 ]
Hu, Yuhua [1 ,2 ]
Zheng, Ou [1 ,2 ]
Guo, Longhua [1 ,2 ]
Lin, Zhenyu [1 ,2 ]
Qiu, Bin [1 ,2 ]
Chen, Guonan [1 ,2 ]
机构
[1] Fuzhou Univ, Dept Chem, MOE Key Lab Anal & Detect Food Safety, Fuzhou 350108, Fujian, Peoples R China
[2] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Fuzhou 350108, Fujian, Peoples R China
来源
关键词
Electrochemiluminescence; Biosensor; Terminal protection; Folate receptor; ELECTROGENERATED CHEMILUMINESCENCE; ELECTROCHEMICAL DETECTION; BINDING; PROTEIN; COMPLEX;
D O I
10.1016/j.bios.2014.02.066
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Owning to the characteristics such as high sensitivity and simplicity of apparatus, electrochemiluminescence (ECL) has become a powerful analytical technique and has been widely used. Ru(phen)(3)(2+) can be intercalated into the grooves of dsDNA and act as an ECL probe efficiently, which has been applied to develop a sensitive ECL biosensor for folate receptor in this study. One ssDNA with a thiol group at its 3' termini had been modified on the Au electrode first, and the other ssDNA with folic acid at its 3' termini hybridized with the former one being modified on the electrode surface to form a dsDNA. In the absence of folate receptor, the 3'-terminus in the dsDNA region can be specificity hydrolyzed into mononucleotides by ExoIII and on dsDNA presents on the electrode surface, leading to the lower of ECL intensity detected. However, in the presence of the target (folate receptor), ExoIII failed to hydrolyze the dsDNA since the one 3'-terminus had been protected by the target and the other protected by the Au electrode, resulting in the enhancement of ECL intensity. The enhanced ECL intensity has a linear relationship with the logarithm of folate receptor concentration in the range of 0.66 nmol/L and 26.31 nmol/L with a detection limit of 0.1204 nmol/L. The proposed biosensor had been applied to detect HeLa cells concentration with satisfied results. (c) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [21] A rapid biosensor for highly sensitive protein detection based on G-quadruplex-Thioflavin T complex and terminal protection of small molecule-linked DNA
    Bai, Dongmei
    Ji, Danyang
    Shang, Jinhua
    Hu, Yalei
    Gao, Jia
    Lin, Zhang
    Ge, Jia
    Li, Zhaohui
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 252 : 1146 - 1152
  • [22] Unmodified and positively charged gold nanoparticles for sensitive colorimetric detection of folate receptor via terminal protection of small molecule-linked ssDNA
    Min Wang
    Fangzhen Li
    Bingying Jiang
    Junqiang Xu
    Shuo Li
    Yun Xiang
    Ruo Yuan
    Science China Chemistry, 2016, 59 : 770 - 775
  • [23] Unmodified and positively charged gold nanoparticles for sensitive colorimetric detection of folate receptor via terminal protection of small molecule-linked ssDNA
    Wang, Min
    Li, Fangzhen
    Jiang, Bingying
    Xu, Junqiang
    Li, Shuo
    Xiang, Yun
    Yuan, Ruo
    SCIENCE CHINA-CHEMISTRY, 2016, 59 (06) : 770 - 775
  • [24] A small-molecule-linked DNA-graphene oxide-based fluorescence-sensing system for detection of biotin
    Zhang, Hao
    Li, Yan
    Su, Xingguang
    ANALYTICAL BIOCHEMISTRY, 2013, 442 (02) : 172 - 177
  • [25] Conjugated cationic polymer-assisted amplified fluorescent biosensor for protein detection via terminal protection of small molecule-linked DNA and graphene oxide
    Zhang, Zhen
    Xia, Xiaoyang
    Xiang, Xia
    Huang, Fenghong
    Han, Ling
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 249 : 8 - 13
  • [26] Ultrasensitive detection of small molecule-protein interaction via terminal protection of small molecule linked DNA and Exo III-aided DNA recycling amplification
    Zhou, Guohua
    Zhang, Xian
    Ji, Xinghu
    He, Zhike
    CHEMICAL COMMUNICATIONS, 2013, 49 (78) : 8854 - 8856
  • [27] A folate receptor electrochemical sensor based on terminal protection and supersandwich DNAzyme amplification
    Wang, Guangfeng
    He, Xiuping
    Wang, Lun
    Zhang, Xiaojun
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 337 - 341
  • [28] Terminal protection of small molecule-linked ssDNA-SWNT nanoassembly for sensitive detection of small molecule and protein interaction
    Wang, Yu
    Zhou, Dian-Ming
    Wu, Zhan
    Tang, Li-Juan
    Jiang, Jian-Hui
    CHINESE CHEMICAL LETTERS, 2013, 24 (02) : 107 - 110
  • [29] Terminal protection of small molecule-linked ssDNA-SWNT nanoassembly for sensitive detection of small molecule and protein interaction
    Yu Wang
    Dian-Ming Zhou
    Zhan Wu
    Li-Juan Tang
    Jian-Hui Jiang
    ChineseChemicalLetters, 2013, 24 (02) : 107 - 110
  • [30] Rapid Detection of Drugs in Human Plasma Using a Small-Molecule-Linked Hybridization Chain Reaction
    Hansen-Bruhn, Malthe
    Nielsen, Line D. F.
    Gothelf, Kurt, V
    ACS SENSORS, 2018, 3 (09): : 1706 - +