Diffusion-Weighted Imaging of the Prostate Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions

被引:35
|
作者
Barth, Borna K. [1 ]
Cornelius, Alexander [2 ]
Nanz, Daniel [1 ]
Eberli, Daniel [3 ]
Donati, Olivio F. [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[2] Cantonal Hosp Aarau, Dept Radiol, Aarau, Switzerland
[3] Univ Zurich Hosp, Dept Urol, CH-8091 Zurich, Switzerland
关键词
diffusion-weighted imaging; magnetic resonance imaging; prostate; read out segmented; reduced field of view; MAGNETIC-RESONANCE; SINGLE-SHOT; 3; T; CLINICAL-APPLICATION; PEDIATRIC BRAIN; GLEASON SCORE; MR; CANCER; EPI; COEFFICIENT;
D O I
10.1097/RLI.0000000000000184
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare image quality and geometric distortion between readout-segmented diffusion-weighted imaging (rs-DWI) and selective-excitation accelerated reduced-field of view (FOV) DWI (sTX-DWI) of the prostate. Materials and Methods Sixty-five patients underwent 3-T MRI of the prostate including rs-DWI and sTX-DWI (b values, 0, 50, and 1000 seconds/mm(2); FOV, 150 x 150 mm(2) and 77 x150 mm(2) for rs-DWI and sTX-DWI; slice thickness, 3 mm; acquisition time, 8:18 min and 1:37 min for rs-DWI and sTX-DWI). Two readers evaluated aspects of image quality and geometric distortion on a 5-point Likert scale. Quantitative analysis of geometric distortion was assessed by measurements of anteroposterior and left-right diameters and compared to T2-weighted turbo-spin echo sequence using intraclass correlation coefficient (ICC). Results There was no significant difference in resolution, capsule demarcation, and zonal anatomy (P = 0.111-0.866). Overall image quality was rated above average by reader 1 (4.09 0.66 and 4.03 0.79; P = 0.433) and reader 2 (3.86 +/- 0.66 and 3.80 +/- 0.74; P = 0.465) for rs-DWI and sTX-DWI. Reader 1 (0.74 +/- 0.67 and 1.17 +/- 0.84; P < 0.001) and reader 2 (0.55 +/- 0.64 and 1.09 +/- 0.95; P < 0.001) rated the level of geometric distortion significantly lower for rs-DWI than sTX-DWI. Readout-segmented DWI (0.9 +/- 2.2 mm) and sTX-DWI (2.1 +/- 3.8 mm) overestimated the anteroposterior diameter of the prostate compared to T2-weighted turbo-spin echo sequence (P < 0.001), the difference being more pronounced for sTX-DWI [ICC, 0.89 (95% confidence interval, 0.83-0.93)] compared to rs-DWI [ICC, 0.96 (95% confidence interval, 0.94-0.96)]. Conclusion Selective-excitation accelerated reduced-FOV DW images (sTX-DWI) of the prostate can be acquired more than 5 times faster than rs-DWI with comparable image quality, at the expense of significantly increased geometric distortion.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [31] Diffusion-Weighted Imaging-guided MR Spectroscopy in Breast Lesions using Readout-Segmented Echo-Planar Imaging
    Kun Sun
    Weimin Chai
    Caixia Fu
    Ying Zhan
    Kunwei Shen
    Xianfu Luo
    Fuhua Yan
    European Radiology, 2016, 26 : 1565 - 1574
  • [32] Editorial for "Simultaneous multislice readout-segmented echo planar imaging for diffusion-weighted MR imaging in patients with invasive breast cancers"
    Liu, Zhuangsheng
    Li, Xiaoping
    Long, Wansheng
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1116 - 1117
  • [33] Diffusion-weighted magnetic resonance imaging in bladder cancer: comparison of readout-segmented and single-shot EPI techniques
    Chen, Haihu
    Chen, Luguang
    Liu, Fang
    Lu, Jianping
    Xu, Chuanliang
    Wang, Li
    CANCER IMAGING, 2019, 19 (01)
  • [34] Diffusion-weighted magnetic resonance imaging in bladder cancer: comparison of readout-segmented and single-shot EPI techniques
    Haihu Chen
    Luguang Chen
    Fang Liu
    Jianping Lu
    Chuanliang Xu
    Li Wang
    Cancer Imaging, 19
  • [35] Accelerated diffusion-weighted imaging of the prostate using deep learning image reconstruction: A retrospective comparison with standard diffusion-weighted imaging
    Ursprung, Stephan
    Herrmann, Judith
    Joos, Natalie
    Weiland, Elisabeth
    Benkert, Thomas
    Almansour, Haidara
    Lingg, Andreas
    Afat, Saif
    Gassenmaier, Sebastian
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165
  • [36] Accelerated Segmented Diffusion-Weighted Prostate Imaging for Higher Resolution, Higher Geometric Fidelity, and Multi-b Perfusion Estimation
    Ciris, Pelin Aksit
    Chiou, Jr-yuan George
    Glazer, Daniel, I
    Chao, Tzu-Cheng
    Tempany-Afdhal, Clare M.
    Madore, Bruno
    Maier, Stephan E.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (04) : 238 - 246
  • [37] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467
  • [38] Advanced diffusion-weighted imaging in patients with optic neuritis deficit - value of reduced field of view DWI and readout-segmented DWI
    Seeger, Achim
    Schulze, Maximilian
    Schuettauf, Frank
    Ernemann, Ulrike
    Hauser, Till-Karsten
    NEURORADIOLOGY JOURNAL, 2018, 31 (02): : 126 - 132
  • [39] Readout-Segmented Echoplanar (RESOLVE) Diffusion-Weighted Imaging on 3T MRI in Detection of Cholesteatoma-Our Experience
    Zaman, Sameeh Uz
    Rangankar, Varsha P.
    Krishnarjun, Muralinath
    Kalekar, Tushar M.
    Shah, Viraj Pankaj
    Pawar, Rishikesh
    Kulothungan, Gowtham
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (01): : 16 - 24
  • [40] Feasibility of Simultaneous Multislice Acceleration Technique in Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Assessing Rectal Cancer
    Zhou, Mi
    Pu, Hong
    Chen, Mei-Ning
    Wang, Yu-Ting
    DIAGNOSTICS, 2023, 13 (03)