Diffusion-Weighted Imaging of the Prostate Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions

被引:35
|
作者
Barth, Borna K. [1 ]
Cornelius, Alexander [2 ]
Nanz, Daniel [1 ]
Eberli, Daniel [3 ]
Donati, Olivio F. [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[2] Cantonal Hosp Aarau, Dept Radiol, Aarau, Switzerland
[3] Univ Zurich Hosp, Dept Urol, CH-8091 Zurich, Switzerland
关键词
diffusion-weighted imaging; magnetic resonance imaging; prostate; read out segmented; reduced field of view; MAGNETIC-RESONANCE; SINGLE-SHOT; 3; T; CLINICAL-APPLICATION; PEDIATRIC BRAIN; GLEASON SCORE; MR; CANCER; EPI; COEFFICIENT;
D O I
10.1097/RLI.0000000000000184
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare image quality and geometric distortion between readout-segmented diffusion-weighted imaging (rs-DWI) and selective-excitation accelerated reduced-field of view (FOV) DWI (sTX-DWI) of the prostate. Materials and Methods Sixty-five patients underwent 3-T MRI of the prostate including rs-DWI and sTX-DWI (b values, 0, 50, and 1000 seconds/mm(2); FOV, 150 x 150 mm(2) and 77 x150 mm(2) for rs-DWI and sTX-DWI; slice thickness, 3 mm; acquisition time, 8:18 min and 1:37 min for rs-DWI and sTX-DWI). Two readers evaluated aspects of image quality and geometric distortion on a 5-point Likert scale. Quantitative analysis of geometric distortion was assessed by measurements of anteroposterior and left-right diameters and compared to T2-weighted turbo-spin echo sequence using intraclass correlation coefficient (ICC). Results There was no significant difference in resolution, capsule demarcation, and zonal anatomy (P = 0.111-0.866). Overall image quality was rated above average by reader 1 (4.09 0.66 and 4.03 0.79; P = 0.433) and reader 2 (3.86 +/- 0.66 and 3.80 +/- 0.74; P = 0.465) for rs-DWI and sTX-DWI. Reader 1 (0.74 +/- 0.67 and 1.17 +/- 0.84; P < 0.001) and reader 2 (0.55 +/- 0.64 and 1.09 +/- 0.95; P < 0.001) rated the level of geometric distortion significantly lower for rs-DWI than sTX-DWI. Readout-segmented DWI (0.9 +/- 2.2 mm) and sTX-DWI (2.1 +/- 3.8 mm) overestimated the anteroposterior diameter of the prostate compared to T2-weighted turbo-spin echo sequence (P < 0.001), the difference being more pronounced for sTX-DWI [ICC, 0.89 (95% confidence interval, 0.83-0.93)] compared to rs-DWI [ICC, 0.96 (95% confidence interval, 0.94-0.96)]. Conclusion Selective-excitation accelerated reduced-FOV DW images (sTX-DWI) of the prostate can be acquired more than 5 times faster than rs-DWI with comparable image quality, at the expense of significantly increased geometric distortion.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [1] Diffusion Tensor Imaging of Lumbar Nerve Roots Comparison Between Fast Readout-Segmented and Selective-Excitation Acquisitions
    Manoliu, Andrei
    Ho, Michael
    Nanz, Daniel
    Piccirelli, Marco
    Dappa, Evelyn
    Klarhofer, Markus
    Del Grande, Filippo
    Kuhn, Felix Pierre
    INVESTIGATIVE RADIOLOGY, 2016, 51 (08) : 499 - 504
  • [2] Robust GRAPPA-Accelerated Diffusion-Weighted Readout-Segmented (RS)-EPI
    Holdsworth, Samantha J.
    Skare, Stefan
    Newbould, Rexford D.
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) : 1629 - 1640
  • [3] Improved diffusion-weighted imaging of the prostate: Comparison of readout-segmented and zoomed single-shot imaging
    Klingebiel, M.
    Weiland, E.
    Boschheidgen, M.
    Ullrich, T.
    Arsov, C.
    Radtke, J. P.
    Benkert, T.
    Nickel, M.
    Strecker, R.
    Wittsack, H. J.
    Albers, P.
    Antoch, G.
    Schimmoeller, L.
    MAGNETIC RESONANCE IMAGING, 2023, 98 : 55 - 61
  • [4] Applicability of readout-segmented echoplanar diffusion weighted imaging for prostate MRI
    Hellms, Susanne
    Gutberlet, Marcel
    Peperhove, Matti Joonas
    Pertschy, Stefanie
    Henkenberens, Christoph
    Peters, Inga
    Wacker, Frank
    Derlin, Katja
    MEDICINE, 2019, 98 (29) : e16447
  • [5] Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast
    Filli, Lukas
    Ghafoor, Soleen
    Kenkel, David
    Liu, Wei
    Weiland, Elisabeth
    Andreisek, Gustav
    Frauenfelder, Thomas
    Runge, Val M.
    Boss, Andreas
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 274 - 278
  • [6] Improved Geometric Performance of Diffusion-Weighted Imaging for Prostate Tumor Delineation Using a Readout-Segmented Echo-Planar-Imaging Technique
    Foltz, W.
    Stanescu, T.
    Lee, J.
    Simeonov, A.
    Jaffray, D.
    Craig, T.
    Chung, P.
    Menard, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S173 - S174
  • [7] Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate
    Stocker, Daniel
    Manoliu, Andrei
    Becker, Anton S.
    Barth, Borna K.
    Nanz, Daniel
    Klarhofer, Markus
    Donati, Olivio F.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (04) : 200 - 206
  • [8] Efficacy of a Nonrigid Image-registration Method in Comparison to Readout-segmented Echo-planar Imaging for Correcting Distortion in Diffusion-weighted Imaging
    Kobata, Takuya
    Yamasaki, Tatsuya
    Katayama, Hiroki
    Ogawa, Kazuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) : 216 - 221
  • [9] Comparison of computed versus acquired readout-segmented diffusion-weighted imaging in visualizing scrotal or testicular lesions
    Yao, F.
    Li, J.
    Huang, M.
    Gao, X.
    Zhang, Y.
    CLINICAL RADIOLOGY, 2024, 79 (11) : 818 - 825
  • [10] Improve the image quality of orbital 3 T diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging
    Xu, Xiao-Quan
    Liu, Jun
    Hu, Hao
    Su, Guo-Yi
    Zhang, Yu-Dong
    Shi, Hai-Bin
    Wu, Fei-Yun
    CLINICAL IMAGING, 2016, 40 (04) : 793 - 796