Development of appropriate thickness ceramic coatings on 316 L stainless steel for biomedical applications

被引:83
|
作者
Gurappa, I [1 ]
机构
[1] Def Met Res Lab, Hyderabad 500058, Andhra Pradesh, India
来源
SURFACE & COATINGS TECHNOLOGY | 2002年 / 161卷 / 01期
关键词
stainless steel; ceramic coatings; corrosion resistance; biomaterials;
D O I
10.1016/S0257-8972(02)00380-8
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this study, ceramics such as alumina, magnesia-stabilized zirconia (MSZ) and yttria-stabilized zirconia (YSZ) of different thicknesses have been deposited over 316 L stainless steel substrate by the air plasma spray (APS) technique. The coated specimens were characterized by scanning electron microscopy (SEM), metallography and X-ray diffraction (XRD) techniques. The coatings of different thicknesses were evaluated for corrosion resistance by various electrochemical techniques in deaerated Hank's solution of pH 7.4 at 37 degreesC, which simulates body fluid conditions. The results revealed that among four different thicknesses of alumina, the 150-mum-thick alumina coating provides good protection and increases the breakdown potential. While all thicknesses of MSZ coating provides very good protection, breakdown potential increases considerably for the 150-mum-thick coating. The breakdown potential increases marginally for the 50-mum-thick YSZ coating. Among the three types of coatings, the MSZ coating has been identified as a suitable coating material and its optimum thickness is 150 mum as it increases the breakdown to a maximum value. Therefore, the present results show that the plasma-sprayed MSZ ceramic coating of 150 mum helps in improving the corrosion resistance of 316 L stainless steel considerably. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:70 / 78
页数:9
相关论文
共 50 条
  • [31] Effect of time, temperature, and solution composition on the passivation of 316L stainless steel for biomedical applications
    Rohly, K
    Istephanous, N
    Belu, A
    Untereker, D
    Coscio, M
    Heffelfinger, J
    Thomas, R
    Allen, J
    Francis, R
    Robinson, A
    Perron, N
    Sahli, B
    Kobielush, B
    THERMEC'2003, PTS 1-5, 2003, 426-4 : 3017 - 3022
  • [32] CYTOTOXIC AND GENOTOXIC STUDY OF IN VITRO RELEASED PRODUCTOS OF STAINLESS STEEL 316L WITH BIOACTIVE CERAMIC COATINGS
    Pareja Lopez, Andres
    Garcia Garcia, Claudia Patricia
    Abad Mejia, Pablo Jesus
    Marquez Fernandez, Maria Elena
    IATREIA, 2007, 20 (01) : 12 - 20
  • [33] Comparative study of corrosion in physiological serum of ceramic coatings applied on 316L stainless steel substrate
    Espitia-Cabrera, M. I.
    Orozco-Hernandez, H. D.
    Espinosa-Medina, M. A.
    Martinez, L.
    Contreras-Garcia, M. E.
    ADVANCES IN SEMICONDUCTING MATERIALS, 2009, 68 : 152 - +
  • [34] Parylene coatings on stainless steel 316L surface for medical applications - Mechanical and protective properties
    Cieslik, Monika
    Kot, Marcin
    Reczynski, Witold
    Engvall, Klas
    Rakowski, Wieslaw
    Kotarba, Andrzej
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (01): : 31 - 35
  • [35] Effect of Initial Surface Scratches on the Cavitation Erosion Behavior of 316L Stainless Steel Substrates and 316L Stainless Steel Coatings
    Lu, Pengfei
    Xu, Ziqi
    Tian, Ye
    Yang, Rui
    Hu, Kaixin
    Li, Hua
    Yin, Yanhong
    Chen, Xiuyong
    MATERIALS, 2023, 16 (04)
  • [36] Low-Cost Deposition of Antibacterial Ion-Substituted Hydroxyapatite Coatings onto 316L Stainless Steel for Biomedical and Dental Applications
    Khan, Abdul Samad
    Awais, Muhammad
    COATINGS, 2020, 10 (09)
  • [37] Impact of Cu and Ce on the electrochemical, antibacterial, and wear properties of 316 L stainless steel: Insights for biomedical applications
    Yamanoglu, Ridvan
    Petkoska, Anka Trajkovska
    Yavuz, Hasan Ismail
    Uzuner, Huseyin
    Drienovsky, Marian
    Nasov, Ilija
    Khoshnaw, Fuad
    MATERIALS TODAY COMMUNICATIONS, 2024, 40
  • [38] Fatigue behavior of annealed cold-sprayed 316L stainless steel coating for biomedical applications
    AL-Mangour, B.
    Dallala, R.
    Zhim, F.
    Mongrain, R.
    Yue, S.
    MATERIALS LETTERS, 2013, 91 : 352 - 355
  • [39] Improving the strength and corrosion resistance of 316L stainless steel for biomedical applications using cold spray
    AL-Mangour, Bandar
    Mongrain, Rosaire
    Irissou, Eric
    Yue, Stephen
    SURFACE & COATINGS TECHNOLOGY, 2013, 216 : 297 - 307
  • [40] Additively manufactured 316L stainless steel with improved corrosion resistance and biological response for biomedical applications
    Lodhi, M. J. K.
    Deen, K. M.
    Greenlee-Wacker, M. C.
    Haider, Waseem
    ADDITIVE MANUFACTURING, 2019, 27 : 8 - 19