Impact of Cu and Ce on the electrochemical, antibacterial, and wear properties of 316 L stainless steel: Insights for biomedical applications

被引:3
|
作者
Yamanoglu, Ridvan [1 ]
Petkoska, Anka Trajkovska [2 ,3 ]
Yavuz, Hasan Ismail [1 ]
Uzuner, Huseyin [4 ]
Drienovsky, Marian [5 ]
Nasov, Ilija [6 ]
Khoshnaw, Fuad [7 ]
机构
[1] Kocaeli Univ, Dept Met & Mat Engn, TR-41001 Kocaeli, Turkiye
[2] St Kliment Ohridski Univ, Fac Technol & Tech Sci, Bitola, North Macedonia
[3] Korea Univ, Dept Mat Sci & Engn, Seoul, South Korea
[4] Kocaeli Univ, Kocaeli Vocat Sch Hlth Serv, Dept Med Serv & Tech, Programme Med Lab Tech, Kocaeli, Turkiye
[5] Slovak Univ Technol Bratislava, Fac Mat Sci & Technol, Bratislava, Slovakia
[6] PLASMA DOO, Ctr Plasma Technol, Skopje, North Macedonia
[7] De Montfort Univ, Sch Engn & Sustainable Dev, Leicester LE1 9BH, England
来源
关键词
Stainless steel; Doping; Cerium; Copper; Tribology; Corrosion; Antibacterial activity; Biomaterials; CORROSION BEHAVIOR; ALLOYS; OXIDE; BIOCOMPATIBILITY; BIOMATERIALS; REGENERATION; RESISTANCE; NICKEL;
D O I
10.1016/j.mtcomm.2024.109442
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study provides a comprehensive investigation of the tribological, electrochemical, and antibacterial characteristics of austenitic stainless steel, type 316 L, doped with Ce and Cu. The samples were doped with varying concentrations of Ce (0.5, 1.5, and 3 wt%) and Cu (1.5, 2.5, and 3.5 wt%). The initial measurements focused on determining the final density values of each sample. Subsequently, friction wear tests were conducted under both dry and wet conditions, shedding light on the wear resistance of the materials. In addition, electrochemical polarization tests were employed to assess the influence of Ce and Cu on the corrosion resistance of AISI 316 L. Furthermore, antibacterial assessments were conducted against bacterial cultures of Staphylococcus aureus (ATCC 29213) and Escherichia coli (ATCC 25922). The findings of this study illuminate several noteworthy outcomes. Namely, the results showed that all Ce and Cu -doped samples exhibited an increase in final density values when compared with the as -received AISI 316 L. The wear test results revealed that samples doped with 0.5 wt% Ce and 2.5 wt% Cu exhibited the highest wear resistance, in both dry and wet environments. Polarization curve analysis indicated that Ce was more effective in enhancing the corrosion resistance of AISI 316 L than Cu. Notably, Ce and Cu modifications endowed the material with antibacterial properties, effectively inhibiting bacterial growth in both S. aureus and E. coli cultures. In summary, this study demonstrates that the addition of even trace amounts of Ce and Cu to AISI 316 L leads to noticeable improvements in the material's tribological, electrochemical, and antibacterial performance, underscoring its potential for diverse biomedical applications. The enhanced mechanical strength, corrosion resistance, and antibacterial activity make the doped material promising for use in various medical devices, implants, and other biomedical applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Impact on the thrombogenicity of surface oxide properties of 316l stainless steel for biomedical applications
    Shih, CC
    Shih, CM
    Su, YY
    Lin, SJ
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (04) : 1320 - 1328
  • [2] The Effect of Nitrided Layer on Antibacterial Properties of Biomedical 316L Stainless Steel
    Benegra, M.
    Couto, G. H.
    Bernardelli, E. A.
    XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 127 - 131
  • [3] Electrochemical in vitro Properties of 316L Stainless Steel for Orthodontic Applications
    Simionescu, Nicoleta
    Ravoiu, Anca
    Benea, Lidia
    REVISTA DE CHIMIE, 2019, 70 (04): : 1144 - 1148
  • [4] Processing and mechanical properties of porous 316L stainless steel for biomedical applications
    Dewidar, Montasser M.
    Khalil, Khalil A.
    Lim, J. K.
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2007, 17 (03) : 468 - 473
  • [5] Processing and mechanical properties of porous 316L stainless steel for biomedical applications
    Montasser M. DEWIDAR
    Khalil A. KHALIL
    J. K. LIM
    TransactionsofNonferrousMetalsSocietyofChina, 2007, (03) : 468 - 473
  • [6] Study of Ce-modified antibacterial 316L stainless steel
    *Yuan Junping 1
    2. Jewelry Institute of Guangzhou Panyu Polytechnic
    China Foundry, 2012, (04) : 307 - 312
  • [7] Study of Ce-modified antibacterial 316L stainless steel
    Yuan Junping Li Wei and Shen Keya Material Science and Engineering Department Jinan University Guangzhou China Jewelry Institute of Guangzhou Panyu Polytechnic Guangzhou China
    China Foundry, 2012, 9 (04) : 307 - 312
  • [8] Study of Ce-modified antibacterial 316L stainless steel
    Yuan Junping
    Li Wei
    Shen Keya
    CHINA FOUNDRY, 2012, 9 (04) : 307 - 312
  • [9] Fabrication of Porous Stainless Steel 316L for Biomedical Applications
    Noor, F. Mat
    Jamaludin, K. R.
    Ahmad, S.
    8TH INTERNATIONAL CONFERENCE ON MECHANICAL AND MANUFACTURING ENGINEERING 2017 (ICME'17), 2017, 135
  • [10] Electrochemical and chemical methods for improving surface characteristics of 316L stainless steel for biomedical applications
    Latifi, Afrooz
    Imani, Mohammad
    Khorasani, Mohammad Taghi
    Joupari, Morteza Daliri
    SURFACE & COATINGS TECHNOLOGY, 2013, 221 : 1 - 12