The development and evaluation of solid-state detector arrays for high energy x-ray imaging

被引:0
|
作者
Li, YL [1 ]
Li, YJ [1 ]
Wang, SF [1 ]
Li, SW [1 ]
He, HL [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Several detector modules which consist of linear CdWO4 crystal arrays optically coupled to photodiode arrays were developed for a high energy X-ray NDT system. An electron linear accelerator (LINAC) which produces pulsive X rays with maximum energy of 9 MeV is used for X ray source. 16 channels were assembled in each module, with crystal size of 0.8 mm x 5 mm x 30 mm and pitch size of 1.3 mm. Lead spacers were placed between crystals to reduce the cross-talk. Based on M-C simulation, the detection efficiency of the detector can reach 70%, energy deposit rate 30%, while crosstalk can be reduced to 5%. After fabrication, we tested their performances under the radiation sources of Co-60, 6 MeV LINAC and 9 MeV LINAC. The results show that the arrays satisfy the meet of the NDT system.
引用
收藏
页码:1374 / 1377
页数:4
相关论文
共 50 条
  • [31] SPATIAL CORRECTION OF SOLID-STATE SEMICONDUCTOR IMAGING DETECTORS IN X-RAY RANGE
    FEDOTOV, MG
    KUPER, EA
    PANCHENKO, VE
    TIUNOV, SA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2332 - 2332
  • [32] An investigation of the imaging performance of a solid state x-ray image detector in continuous fluoroscopy
    Davies, AG
    Cowen, AR
    Kengyelics, SM
    Bury, RF
    Briujns, TJ
    Busse, F
    RADIOLOGY, 1999, 213P : 235 - 235
  • [33] USE OF SOLID-STATE DETECTORS FOR ROUTINE EVALUATION OF DIAGNOSTIC X-RAY EQUIPMENT
    GOODWIN, PN
    DRILLER, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 183 - &
  • [34] Studies of a solid detector array for high energy X-ray imaging system based on MA-PMT
    Li, Yulan
    Li, Yuanjing
    Xu, Libai
    Wang, Shaofeng
    Cao, Liangjun
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 725 - 728
  • [35] Noise Evaluation of a New Solid-State X-Ray Image Intensifier (SSXII)
    Kuhls-Gilcrist, A.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2008, 35 (06) : 2869 - +
  • [36] DEVELOPMENT OF A PROGRAM IN SOLID-STATE GEOCHEMISTRY UTILIZING X-RAY SPECTROMETRIC TECHNIQUES
    BERRY, KO
    EGGERS, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 64 - CHED
  • [37] A GE SOLID-STATE DETECTOR AS AN X-RAY FILTER WITH A 5 EV BANDPASS AT 11.1 KEV
    SCHULKE, W
    MOURIKIS, S
    LIEDTKE, KD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 266 - 269
  • [38] X-Ray fluorescence determination of impurity traces using a secondary emitter and a solid-state detector
    Mikhailov, I. F.
    Baturin, A. A.
    Fomina, L. P.
    FUNCTIONAL MATERIALS, 2010, 17 (01): : 127 - 130
  • [39] SOLID-STATE CHEMISTRY AND LUMINESCENCE OF X-RAY PHOSPHORS
    ISSLER, SL
    TORARDI, CC
    JOURNAL OF ALLOYS AND COMPOUNDS, 1995, 229 (01) : 54 - 65
  • [40] A SOLID-STATE DIGITAL INTEGRATING X-RAY DOSEMETER
    KEMP, LAW
    BOTTRILL, DO
    KLEVENHAGEN, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (02): : 231 - +