The development and evaluation of solid-state detector arrays for high energy x-ray imaging

被引:0
|
作者
Li, YL [1 ]
Li, YJ [1 ]
Wang, SF [1 ]
Li, SW [1 ]
He, HL [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Several detector modules which consist of linear CdWO4 crystal arrays optically coupled to photodiode arrays were developed for a high energy X-ray NDT system. An electron linear accelerator (LINAC) which produces pulsive X rays with maximum energy of 9 MeV is used for X ray source. 16 channels were assembled in each module, with crystal size of 0.8 mm x 5 mm x 30 mm and pitch size of 1.3 mm. Lead spacers were placed between crystals to reduce the cross-talk. Based on M-C simulation, the detection efficiency of the detector can reach 70%, energy deposit rate 30%, while crosstalk can be reduced to 5%. After fabrication, we tested their performances under the radiation sources of Co-60, 6 MeV LINAC and 9 MeV LINAC. The results show that the arrays satisfy the meet of the NDT system.
引用
收藏
页码:1374 / 1377
页数:4
相关论文
共 50 条
  • [21] Development of energy discriminated CdTe imaging detector for hard X-ray
    Aoki, T
    Ishida, Y
    Sakashita, D
    Gnatyuk, VA
    Nakamura, A
    Tomita, Y
    Hatanaka, Y
    Temmyo, J
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS VI, 2004, 5540 : 196 - 205
  • [22] Development of a digital X-ray imaging detector
    Ronnqvist, C
    Pedersen, F
    Fransson, K
    Gustafsson, L
    Kullander, S
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1607 - 1611
  • [23] Solid-state detector design for mobile cargo container inspection system using medium energy X-ray
    Kwak, SW
    Kim, KH
    Cho, G
    Kim, I
    Yi, Y
    Han, B
    Goh, SM
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 475 - 479
  • [24] SOLID-STATE DETECTORS IN X-RAY SPECTROMETRY
    LAURIAT, JP
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1980, 5 (01): : 63 - 70
  • [25] APPLICATIONS OF A SOLID-STATE DETECTOR ON A MODERN SINGLE-CRYSTAL X-RAY DIFFRACTOMETER
    MULLICA, DF
    BEALL, GW
    MILLIGAN, WO
    OLIVER, JD
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1979, 12 (JUN) : 263 - 266
  • [26] POTENTIAL OF LITHIUM-DRIFTED SOLID-STATE DETECTOR IN X-RAY FLUORESCENCE ANALYSIS
    HEATH, RL
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 35 - +
  • [27] MEASUREMENT OF TOTALLY DEPLETED SILICON SOLID-STATE DETECTOR THICKNESS BY X-RAY ATTENUATION
    HANSER, FA
    SELLERS, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (02): : 226 - 231
  • [28] Solid-state pulser development for high power dense plasma focus X-ray sources
    Petr, Rodney
    Reilly, Dennis
    Freshman, Jay
    Orozco, Nelson
    Pham, Dan
    Ngo, Long
    Mangano, Joseph
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2000, 39 (2 A): : 607 - 611
  • [29] Solid-state pulser development for high power dense plasma focus X-ray sources
    Petr, R
    Reilly, D
    Freshman, J
    Orozco, N
    Pham, D
    Ngo, L
    Mangano, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (2A): : 607 - 611
  • [30] SPATIAL CORRECTION OF SOLID-STATE SEMICONDUCTOR IMAGING DETECTORS IN THE X-RAY REGION
    FEDOTOV, MG
    KUPER, EA
    PANCHENKO, VE
    TIUNOV, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 423 - 426