Detection of magnetic nanoparticles with superconducting quantum interference device (SQUID) magnetometer and application to immunoassays

被引:125
|
作者
Enpuku, K [1 ]
Minotani, T
Gima, T
Kuroki, Y
Itoh, Y
Yamashita, M
Katakura, Y
Kuhara, S
机构
[1] Kyushu Univ, Dept Elect Device Engn, Higashi Ku, Fukuoka 8128581, Japan
[2] Kyushu Univ, Grad Sch Genet Resources Technol, Fukuoka 8128581, Japan
来源
关键词
SQUID magnetometer; magnetic nanoparticle; magnetization; antigen-antibody reaction; immunoassay; high T-c superconductor;
D O I
10.1143/JJAP.38.L1102
中图分类号
O59 [应用物理学];
学科分类号
摘要
A system is developed to magnetically measure biological antigen-antibody reactions with a superconducting quantum interference device (SQUID) magnetometer. In this system, antibodies are labeled with magnetic nanoparticles of g-Fe2O3, and the antigen-antibody reactions are measured by detecting the magnetic field from the magnetic nanoparticles. A setup of the system is described, and the sensitivity of the system is studied in terms of detectable weight of nanoparticles. Magnetic particles as small as 600 pg can be detected at present. An experiment is also conducted to measure antigen-antibody reaction with the present system. It is shown that the sensitivity of the present system is better than that of the conventional optical method. A one order of magnitude improvement of sensitivity will be realized by the sophistication of the present system.
引用
收藏
页码:L1102 / L1105
页数:4
相关论文
共 50 条
  • [21] Low-frequency noise of high Tc superconducting quantum interference device (SQUID) magnetometer fabricated on bicrystal substrate
    Minotani, Tadashi
    Hotta, Masahiro
    Enpuku, Keiji
    Japanese Journal of Applied Physics, Part 2: Letters, 2000, 39 (5 A):
  • [22] Low-frequency noise of high Tc superconducting quantum interference device (SQUID) magnetometer fabricated on bicrystal substrate
    Minotani, T
    Hotta, M
    Enpuku, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2000, 39 (5A): : L402 - L405
  • [23] Nano Superconducting QUantum Interference Device Sensors for Magnetic Nanoparticle Detection
    Esposito, E.
    Granata, C.
    Vettoliere, A.
    Russo, R.
    Peddis, D.
    Russo, M.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (09) : 7468 - 7472
  • [24] Highly Sensitive Tunable Magnetometer Based on Superconducting Quantum Interference Device
    Vettoliere, Antonio
    Granata, Carmine
    SENSORS, 2023, 23 (07)
  • [25] Large inductance superconducting quantum interference device magnetometer for magnetoencephalography measurement
    Ahmad, RS
    Kubo, M
    Hirata, Y
    Kuriki, S
    Nakayama, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1997, 36 (11): : 6737 - 6741
  • [26] DC superconducting quantum interference device magnetometer for cryogenic current comparator
    Nakanishi, Masakazu
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1994, 33 (10): : 5713 - 5717
  • [27] Large inductance superconducting quantum interference device magnetometer for magnetoencephalography measurement
    Ahmad, Rashdi Shah
    Kubo, Masateru
    Hirata, Yoshihiro
    Kuriki, Shinya
    Nakayama, Satoshi
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (11): : 6737 - 6741
  • [28] DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER FOR CRYOGENIC CURRENT COMPARATOR
    NAKANISHI, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (10): : 5713 - 5717
  • [29] A low field superconducting quantum interference device magnetometer for dynamic measurements
    Magnusson, J
    Djurberg, C
    Granberg, P
    Nordblad, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (10): : 3761 - 3765
  • [30] Ultrahigh vacuum compatible superconducting quantum interference device magnetometer system for studies of magnetic thin films
    Spagna, S
    Sager, RE
    Maple, MB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12): : 5570 - 5576