Mechanism of and factors associated with the loosening of the implant abutment screw: A review

被引:87
|
作者
Huang, Yiqing [1 ,2 ]
Wang, Jiawei [1 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, Hubei MOST KLOS & KLOBM, Dept Prosthodont, Wuhan, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Cent Hosp Wuhan, Dept Stomatol, Tongji Med Coll, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
abutment screw; implant; mechanical complication; screw loosening; IN-VITRO EVALUATION; TORQUE REMOVAL EVALUATION; DENTAL PROSTHESES FDPS; INTERNAL TRI-CHANNEL; COMPLICATION RATES; ROTATIONAL FREEDOM; INTERCHANGEABLE ABUTMENTS; AESTHETIC COMPLICATIONS; PRELOAD MAINTENANCE; RETENTION SCREWS;
D O I
10.1111/jerd.12494
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective While the loosening of the abutment screw is one of the most common complications in implant-supported restorations, there is a lack of comprehensive literatures for mechanism of and factors associated with the loosening of the implant abutment screw. The review was to summarize the mechanism of and factors associated with the loosening of the implant abutment screw. Overview A total of 99 relevant articles were included in the literature review. The mechanism of the abutment screw loosening was explained. The factors contributed to abutment screw loosening were divided into five aspects and then expounded respectively. Conclusions The internal connection and abutments with anti-rotational and conical designs have better resistance to screw loosening. Cantilevers increase the risk of screw loosening. The effect of surface treatment of the abutment screw is unsure. Clinicians need to tighten the abutment screw to the recommended torque while avoiding repeated tightening and loosening, and increase the frequency of follow-ups to retighten the loosened screws in time. Clinical Significance While the loosening of the abutment screw is one of the most common complications in implant-supported restorations, there is a lack of comprehensive literatures for mechanism of and factors associated with the loosening of the implant abutment screw. The review was to summarize the mechanism of and factors associated with the loosening of the implant abutment screw, so that clinicians may make better choices in clinical practice.
引用
收藏
页码:338 / 345
页数:8
相关论文
共 50 条
  • [21] Different Methods to Salvage the Fractured Abutment Screws and Potential Reasons of Abutment Screw Loosening: A Narrative Review
    Gir, Prajakta
    Joshi, Snehal
    Vishnupriya, V.
    Marathe, Ashlesha
    Bagul, Abhishek
    Nazirkar, Girish
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 5) : S4198 - S4200
  • [22] Antimicrobial profile of a dental implant abutment coating to prevent adhesion and migration of bacteria and screw loosening
    Rodrigues, M. A.
    Cortez, A. R.
    Cortez, J.
    Gobbo, P.
    Lepicka, M.
    Barros-Silva, S.
    Freitas, P. P.
    Lopes, M. A.
    Mendes, J.
    DENTAL MATERIALS, 2021, 37 (10) : E493 - E501
  • [23] Implant abutment screw fracture and techniques of retrieval: a literature review based on a novel abutment screw fracture classification
    Chowdhary, R.
    Sonnahalli, N. K.
    Gala, J. N.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (01) : 32 - 39
  • [24] Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
    Rico-Coderch, Aitana
    Felix, Luis F.
    Sola-Ruiz, Maria Fernanda
    Medina, Michell
    Agustin-Panadero, Ruben
    Ortega, Rocio
    Cascos, Rocio
    Gomez-Polo, Miguel
    METALS, 2024, 14 (07)
  • [25] The Effect of Abutment Screw Length on Screw Loosening in Dental Implants with External Abutment Connections After Thermocycling
    Yeo, In-Sung
    Lee, Joo-Hee
    Kang, Tae-Joo
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    Park, Ji-Man
    Lee, Su-Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 59 - 62
  • [26] Procedure for obturating the access canal and preventing the loosening of the abutment screw in an implant-retained fixed prosthesis
    von Krammer, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (02): : 234 - 236
  • [27] Study of Screw Loosening in Abutment Subject to Occlusal Loading
    Cheng, E-Hsung
    Lin, Ming-Jer
    Shiu, Sheng-Yan
    Tsai, Tung-Lin
    Chen, Yi-Chin
    ADVANCED MATERIALS, PTS 1-3, 2012, 415-417 : 2166 - 2171
  • [28] Deformation of dental abutment screw after tightening and loosening
    Kim, Hee Jung
    Choe, Han Cheol
    Chung, Chae Heon
    Brantley, William
    MECHANICAL BEHAVIOR OF MATERIALS X, PTS 1AND 2, 2007, 345-346 : 13 - +
  • [29] Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study
    Ahmed, Syed Ershad
    Krishnan, Chitra Shankar
    Mohan, Jayashree
    Kalaignan, Parithimar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (02)
  • [30] Tightening and Loosening of the Abutment Screw Negatively Affects Implant Osseointegration in the Early Healing Stage in Rat Tibiae
    Shobara, Kenta
    Ogawa, Toru
    Sitalaksmi, Ratri M.
    Ito, Akiyo
    Miyashita, Makiko
    Shibamoto, Aya
    Sasaki, Keiichi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (02) : 199 - 203