Evaluation of nanospray capillary LC-MS performance for metabolomic analysis in complex biological matrices

被引:11
|
作者
Grinias, James P. [2 ]
Edwards, James L. [1 ]
Mostafa, Mahmoud Elhusseiny [1 ]
机构
[1] St Louis Univ, Dept Chem & Biochem, 3501 Laclede Ave, St Louis, MO 63103 USA
[2] Rowan Univ, Dept Chem & Biochem, 201 Mull Hill Rd, Glassboro, NJ 08028 USA
基金
美国国家科学基金会;
关键词
Metabolomics; Optimization; Capillary LC; Nanospray; HPLC; MS; Ion trap; Orbitrap; Degeneracy; Human serum; E; coli; PEAK-CAPACITY; DIFFUSION-COEFFICIENTS; MASS; CHROMATOGRAPHY; COLUMN; OPTIMIZATION; ESI; SEPARATIONS; ANNOTATION; DIAMETER;
D O I
10.1016/j.chroma.2022.462952
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
LC-MS metabolomic analysis in complex biological matrices may be complicated by degeneracy when using large-bore columns. Degeneracy is the detection of multiple mass spectral peaks from the same analyte due to adduction of salts to the metabolite, dimerization, or loss of neutrals. This introduces interferences to the MS spectra, diminishes quantification, and increases the rate of false identifications. Analysis using 2.1 mm inner diameter (i.d.) columns typically leads to degenerate peaks whereas nanospray using capillary columns (25, 50, and 75 mu m i.d.) reduces degeneracy. Optimization of chromatographic parameters of capillary LC for amino acid standards showed the lowest HETP at 1.25 mm/sec across all capillary i.d. columns. Results suggest mass-sensitive detection below the optimum velocity. At faster velocities, concentration-dependent detection occurred across all capillaries. The 2.1 mm i.d. analytical scale column showed the greatest level of degeneracy, particularly in the low signal intensity range. 25 mu m i.d. columns showed higher levels of metabolite annotation for the same signal intensity range. It also provided the lowest level of degeneracy, making it best suited for untargeted analysis. The 25 mu m i.d. column achieved a peak capacity (n(c)) of 144 in a 30-minute gradient method with nc decreasing as the column i.d. increased. 75 mu m i.d. capillary columns showed the highest signal intensity, which is beneficial for targeted analysis. These effects of chromatographic performance, resolution, and degeneracy profile of capillary and analytical scale columns were compared for metabolomic analyses in complex serum and cell lysate matrices. (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] ESTIMATION OF TERIFLUNOMIDE ALONG WITH CONCOMITANT DRUGS IN DIFFERENT BIOLOGICAL MATRICES USING LC-MS/MS
    Suneetha, A.
    Rajeswari, Raja K.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2015, 6 (05): : 1915 - 1923
  • [42] Antibody based affinity capture LC-MS/MS in quantitative determination of proteins in biological matrices
    Halvorsen, Trine Gronhaug
    Reubsaet, Leon
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 95 : 132 - 139
  • [43] LC-MS/MS based analytical strategies for the detection of lipid peroxidation products in biological matrices
    Fanti, Federico
    Sergi, Manuel
    Compagnone, Dario
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 256
  • [44] Performance Evaluation of LC-MS Methods for Multimycotoxin Determination
    Pascale, Michelangelo
    De Girolamo, Annalisa
    Lippolis, Vincenzo
    Stroka, Joerg
    Mol, Hans G. J.
    Lattanzio, Veronica M. T.
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (06) : 1708 - 1720
  • [45] Evaluation of performance of LC-MS/MS assay for determination of mycophenolic acid
    Yun, Y. M.
    Noh, J.
    Song, J.
    CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 913 - 914
  • [46] Normalizing and Correcting Variable and Complex LC-MS Metabolomic Data with the R Package pseudoDrift
    Rodriguez, Jonas
    Gomez-Cano, Lina
    Grotewold, Erich
    de Leon, Natalia
    METABOLITES, 2022, 12 (05)
  • [47] Improving LC-MS/MS analyses in complex food matrices, Part II -: Mass spectrometry
    Zöllner, P
    Leitner, A
    Jodlbauer, J
    Mayer, BX
    Linder, W
    LC GC EUROPE, 2003, 16 (06) : 354 - +
  • [48] Assessment of blueberry juice adulteration through LC-MS absed metabolomic analysis
    Auh, Joong-Hyuck
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [49] Ion annotation-assisted analysis of LC-MS based metabolomic experiment
    Varghese, Rency S.
    Zhou, Bin
    Ranjbar, Mohammad R. Nezami
    Zhao, Yi
    Ressom, Habtom W.
    PROTEOME SCIENCE, 2012, 10
  • [50] Ion annotation-assisted analysis of LC-MS based metabolomic experiment
    Rency S Varghese
    Bin Zhou
    Mohammad R Nezami Ranjbar
    Yi Zhao
    Habtom W Ressom
    Proteome Science, 10