Evaluation of nanospray capillary LC-MS performance for metabolomic analysis in complex biological matrices

被引:11
|
作者
Grinias, James P. [2 ]
Edwards, James L. [1 ]
Mostafa, Mahmoud Elhusseiny [1 ]
机构
[1] St Louis Univ, Dept Chem & Biochem, 3501 Laclede Ave, St Louis, MO 63103 USA
[2] Rowan Univ, Dept Chem & Biochem, 201 Mull Hill Rd, Glassboro, NJ 08028 USA
基金
美国国家科学基金会;
关键词
Metabolomics; Optimization; Capillary LC; Nanospray; HPLC; MS; Ion trap; Orbitrap; Degeneracy; Human serum; E; coli; PEAK-CAPACITY; DIFFUSION-COEFFICIENTS; MASS; CHROMATOGRAPHY; COLUMN; OPTIMIZATION; ESI; SEPARATIONS; ANNOTATION; DIAMETER;
D O I
10.1016/j.chroma.2022.462952
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
LC-MS metabolomic analysis in complex biological matrices may be complicated by degeneracy when using large-bore columns. Degeneracy is the detection of multiple mass spectral peaks from the same analyte due to adduction of salts to the metabolite, dimerization, or loss of neutrals. This introduces interferences to the MS spectra, diminishes quantification, and increases the rate of false identifications. Analysis using 2.1 mm inner diameter (i.d.) columns typically leads to degenerate peaks whereas nanospray using capillary columns (25, 50, and 75 mu m i.d.) reduces degeneracy. Optimization of chromatographic parameters of capillary LC for amino acid standards showed the lowest HETP at 1.25 mm/sec across all capillary i.d. columns. Results suggest mass-sensitive detection below the optimum velocity. At faster velocities, concentration-dependent detection occurred across all capillaries. The 2.1 mm i.d. analytical scale column showed the greatest level of degeneracy, particularly in the low signal intensity range. 25 mu m i.d. columns showed higher levels of metabolite annotation for the same signal intensity range. It also provided the lowest level of degeneracy, making it best suited for untargeted analysis. The 25 mu m i.d. column achieved a peak capacity (n(c)) of 144 in a 30-minute gradient method with nc decreasing as the column i.d. increased. 75 mu m i.d. capillary columns showed the highest signal intensity, which is beneficial for targeted analysis. These effects of chromatographic performance, resolution, and degeneracy profile of capillary and analytical scale columns were compared for metabolomic analyses in complex serum and cell lysate matrices. (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
    Tan, Bo
    Jin, Sheng
    Sun, Jiping
    Gu, Zhongkai
    Sun, Xiaotian
    Zhu, Yichun
    Huo, Keke
    Cao, Zonglian
    Yang, Ping
    Xin, Xiaoming
    Liu, Xinhua
    Pan, Lilong
    Qiu, Furong
    Jiang, Jian
    Jia, Yiqun
    Ye, Fuyuan
    Xie, Ying
    Zhu, Yi Zhun
    SCIENTIFIC REPORTS, 2017, 7
  • [32] Metabolomic study of the organophosphates and the antidotes by using LC-MS/MS
    Jin, Shan
    DRUG METABOLISM REVIEWS, 2011, 43 : 122 - 122
  • [33] Sensitive Analysis of Nitroguanidine in Aqueous and Soil Matrices by LC-MS
    Rossin, Anna Voloshenko
    Sladkevich, Sergey
    Gasser, Guy
    Melman, Artem
    Lev, Ovadia
    ANALYTICAL CHEMISTRY, 2017, 89 (18) : 9990 - 9996
  • [34] LC-MS/MS based metabolomic analysis of serum from patients with cerebrovascular stenosis
    Shan, Dezhi
    Qi, Peng
    Wang, Daming
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [35] The integration of LC-MS and NMR for the analysis of low molecular weight trace analytes in complex matrices
    Gathungu, Rose M.
    Kautz, Roger
    Kristal, Bruce S.
    Bird, Susan S.
    Vouros, Paul
    MASS SPECTROMETRY REVIEWS, 2020, 39 (1-2) : 35 - 54
  • [36] Comparative Analysis of Biological Sphingolipids with Glycerophospholipids and Diacylglycerol by LC-MS/MS
    Ogiso, Hideo
    Taniguchi, Makoto
    Araya, Shinichi
    Aoki, Shinya
    Wardhani, Lusi Oka
    Yamashita, Yuka
    Ueda, Yoshibumi
    Okazaki, Toshiro
    METABOLITES, 2014, 4 (01) : 98 - 114
  • [37] GC-MS and LC-MS approaches for determination of tocopherols and tocotrienols in biological and food matrices
    Bartosinska, E.
    Buszewska-Forajta, M.
    Siluk, D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 127 : 156 - 169
  • [38] Development of a Drug Screening Method in Biological Matrices Using an Hybrid LC-MS/MS System
    Viette, V.
    Fathi, M.
    Hochstrasser, D.
    Mylonas, R.
    Mauron, Y.
    Rudaz, S.
    Veuthey, J. -L.
    THERAPEUTIC DRUG MONITORING, 2009, 31 (05) : 604 - 605
  • [39] Absolute quantitation of protein therapeutics in biological matrices by enzymatic digestion and LC-MS
    Li, Fumin
    Fast, Douglas
    Michael, Steve
    BIOANALYSIS, 2011, 3 (21) : 2459 - 2480
  • [40] Fatal cytisine intoxication and analysis of biological samples with LC-MS/MS
    Musshoff, F.
    Madea, B.
    FORENSIC SCIENCE INTERNATIONAL, 2009, 186 (1-3) : E1 - E4