Evaluation of nanospray capillary LC-MS performance for metabolomic analysis in complex biological matrices

被引:11
|
作者
Grinias, James P. [2 ]
Edwards, James L. [1 ]
Mostafa, Mahmoud Elhusseiny [1 ]
机构
[1] St Louis Univ, Dept Chem & Biochem, 3501 Laclede Ave, St Louis, MO 63103 USA
[2] Rowan Univ, Dept Chem & Biochem, 201 Mull Hill Rd, Glassboro, NJ 08028 USA
基金
美国国家科学基金会;
关键词
Metabolomics; Optimization; Capillary LC; Nanospray; HPLC; MS; Ion trap; Orbitrap; Degeneracy; Human serum; E; coli; PEAK-CAPACITY; DIFFUSION-COEFFICIENTS; MASS; CHROMATOGRAPHY; COLUMN; OPTIMIZATION; ESI; SEPARATIONS; ANNOTATION; DIAMETER;
D O I
10.1016/j.chroma.2022.462952
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
LC-MS metabolomic analysis in complex biological matrices may be complicated by degeneracy when using large-bore columns. Degeneracy is the detection of multiple mass spectral peaks from the same analyte due to adduction of salts to the metabolite, dimerization, or loss of neutrals. This introduces interferences to the MS spectra, diminishes quantification, and increases the rate of false identifications. Analysis using 2.1 mm inner diameter (i.d.) columns typically leads to degenerate peaks whereas nanospray using capillary columns (25, 50, and 75 mu m i.d.) reduces degeneracy. Optimization of chromatographic parameters of capillary LC for amino acid standards showed the lowest HETP at 1.25 mm/sec across all capillary i.d. columns. Results suggest mass-sensitive detection below the optimum velocity. At faster velocities, concentration-dependent detection occurred across all capillaries. The 2.1 mm i.d. analytical scale column showed the greatest level of degeneracy, particularly in the low signal intensity range. 25 mu m i.d. columns showed higher levels of metabolite annotation for the same signal intensity range. It also provided the lowest level of degeneracy, making it best suited for untargeted analysis. The 25 mu m i.d. column achieved a peak capacity (n(c)) of 144 in a 30-minute gradient method with nc decreasing as the column i.d. increased. 75 mu m i.d. capillary columns showed the highest signal intensity, which is beneficial for targeted analysis. These effects of chromatographic performance, resolution, and degeneracy profile of capillary and analytical scale columns were compared for metabolomic analyses in complex serum and cell lysate matrices. (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Analysis of biopharmaceutical proteins in biological matrices by LC-MS/MS II. LC-MS/MS analysis
    Hopfgartner, Gerard
    Lesur, Antoine
    Varesio, Emmanuel
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 48 : 52 - 61
  • [2] LC-MS/MS quantitation of phytocannabinoids and their metabolites in biological matrices
    Abd-Elsalam, Wessam H.
    Alsherbiny, Muhammad A.
    Kung, Janice Y.
    Pate, David W.
    Lobenberg, Raimar
    TALANTA, 2019, 204 : 846 - 867
  • [3] Strategies in quantitative LC-MS/MS analysis of unstable small molecules in biological matrices
    Li, Wenkui
    Zhang, Jie
    Tse, Francis L. S.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (1-2) : 258 - 277
  • [4] A concise review of HPLC, LC-MS and LC-MS/MS methods for determination of azithromycin in various biological matrices
    Sharma, Kuldeep
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (10) : 1243 - 1258
  • [5] LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices
    Choi, BK
    Hercules, DM
    Gusev, AI
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (3-4): : 370 - 377
  • [6] LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices
    B. K. Choi
    D. M. Hercules
    A. I. Gusev
    Fresenius' Journal of Analytical Chemistry, 2001, 369 : 370 - 377
  • [8] Evaluation of ELISA for the analysis of imidacloprid in biological matrices: Cross-reactivities, matrix interferences, and comparison to LC-MS/MS
    Gross, Michael S.
    Woodward, Emily E.
    Hladik, Michelle L.
    CHEMOSPHERE, 2022, 286
  • [9] Metabolomic Analysis and Visualization Engine for LC-MS Data
    Melamud, Eugene
    Vastag, Livia
    Rabinowitz, Joshua D.
    ANALYTICAL CHEMISTRY, 2010, 82 (23) : 9818 - 9826
  • [10] Automated and unbiased analysis of LC-MS metabolomic data
    Hnatyshyn, Serhiy
    Shipkova, Petia
    BIOANALYSIS, 2012, 4 (05) : 541 - 554