Simultaneous determination of glimepiride and pioglitazone in human plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study

被引:19
|
作者
Ni, Xiao-Jia [1 ]
Wang, Zhan-Zhang [2 ]
Shang, De-Wei [1 ]
Zhang, Ming [1 ]
Hu, Jin-Qing [2 ]
Qiu, Chang [2 ]
Wen, Yu-Guan [1 ]
机构
[1] Guangzhou Med Univ, Inst Natl Drug Clin Trials, Clin Lab Phase 1, Guangzhou Brain Hosp, Guangzhou 510370, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Clin Pharm Guangzhou Brain Hosp, Guangzhou 510370, Guangdong, Peoples R China
关键词
LC-MS/MS; Glimepiride; Pioglitazone; Pharmacokinetic; INSULIN SENSITIVITY; HUMAN SERUM; LC-MS/MS; ALLOPURINOL; OXYPURINOL; METFORMIN; URINE;
D O I
10.1016/j.jchromb.2014.04.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rapid, sensitive, and selective liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) for the simultaneous estimation and pharmacokinetic investigation of glimepiride and pioglitazone in human plasma has been developed and fully validated. Glimepiride and pioglitazone, compounds which exert synergistic effects on blood glucose control, were investigated in human plasma using deuterium-labeled analogs as internal standards (IS). Liquid-liquid extraction was carried out on 0.2 mL of human plasma using ethyl acetate, and chromatographic separation was performed on an Agilent Eclipse plus C-18 column (4.6 mm x 100 mm, 3.5 mu m) using a mobile phase consisting of methanol-water-formic acid (95:5:0.1, v/v/v, plus 5 mM ammonium acetate) at a flow rate of 0.8 mL/min. To quantify glimepiride, pioglitazone and their IS, multiple reaction monitoring (MRM) transitions of m/z 491.2 -> 352.2, m/z 496.2 -> 357.2, m/z 357.2 -> 134.2 and m/z 361.2 -> 138.2 were performed in positive mode. The total run time was 3.0 min and the elution time was about 2.4 min. The method exhibited good separation of analytes, without interference from endogenous substances. The linear calibration curves were 0.2-250 ng/mL for glimepiride and 0.2-1250 ng/mL for pioglitazone; the lower limit of quantification (LLOQ) was 0.2 ng/mL for both analytes. Intra- and inter-day reproducibility was less than 10% for glimepiride and less than 5% for pioglitazone, with relative errors ranging from -8.00% to 2.80% at the three concentrations of analytes used for quality control (QC). The matrix effect was negligible and recoveries were similar for each analyte and its IS. Glimepiride and pioglitazone were found to be stable under the assay conditions and the method was successfully applied to the evaluation of pharmacokinetic studies of glimepiride and pioglitazone, following oral doses of 2 mg glimepiride tablets and 15 mg pioglitazone tablets to 16 healthy volunteers. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 252
页数:6
相关论文
共 50 条
  • [41] Quantitative determination of lisinopril in human plasma by high performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Qin, Feng
    Wang, Dan
    Yang, Shuyan
    Jing, Lijuan
    Xiong, Zhili
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (06) : 691 - 696
  • [42] Determination of tamsulosin in human plasma by liquid chromatography/tandem mass spectrometry and its application to a pharmacokinetic study
    Choi, Chang-Ik
    Lee, Hye-In
    Bae, Jung-Woo
    Lee, Yun-Jeong
    Byeon, Ji-Yeong
    Jang, Choon-Gon
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 909 : 65 - 69
  • [43] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of cefixime in human plasma: Application to a pharmacokinetic study
    Meng, F
    Chen, XY
    Zeng, YL
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (02): : 277 - 282
  • [44] New validated liquid chromatography-tandem mass spectrometry method for the determination of Dacomitinib in human plasma and its application to a pharmacokinetic study
    Gupta, Tinku
    Sahoo, NaliniKanta
    Rambabu, Maddela
    Praveen, M.
    Charde, Shrikant
    Sahu, Madhusmita
    Chakrabarti, Prasun
    Hung, Bui Thanh
    Margala, Martin
    Unhelkar, Bhuvan
    Narayanankutty, Arunaksharan
    SEPARATION SCIENCE PLUS, 2024, 7 (02)
  • [45] Liquid Chromatography-Tandem Mass Spectrometry Method for Ticagrelor and its Active Metabolite Determination in Human Plasma: Application to a Pharmacokinetic Study
    Marsousi, Niloufar
    Rudaz, Serge
    Desmeules, Jules A.
    Daali, Youssef
    CURRENT ANALYTICAL CHEMISTRY, 2020, 16 (05) : 602 - 608
  • [46] Development of a liquid chromatography-tandem mass spectrometry method for determination of butoconazole nitrate in human plasma and its application to a pharmacokinetic study
    Meng-meng Jia
    Ying Zhou
    Xiao-meng He
    Yi-lai Wu
    Hu-qun Li
    Hui Chen
    Wei-yong Li
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2014, 34 : 431 - 436
  • [47] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of phenylephrine in human plasma and its application to a pharmacokinetic study
    Ptácek, P.
    Klíma, J.
    Macek, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 263 - 268
  • [48] Validated liquid chromatography-tandem mass spectrometry method for quantitative determination of dauricine in human plasma and its application to pharmacokinetic study
    Liu, Xiaoying
    Liu, Qian
    Wang, Dongmei
    Wang, Xueya
    Zhang, Peng
    Xu, Haiyan
    Zhao, Hui
    Zhao, Huaiqing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1199 - 1203
  • [49] Determination of lomerizine in human plasma by liquid chromatography/tandem mass spectrometry and its application to a pharmacokinetic study
    Ren, Yulong
    Liu, Tianshun
    Song, Guoxin
    Hu, Yaoming
    Liang, Jianying
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 96 - 102
  • [50] High-performance liquid chromatography-tandem mass spectrometry for the determination of pidotimod in human plasma and its application to a pharmacokinetic study
    Zhang, Yi
    Xiong, Zhili
    Qin, Feng
    Lu, Shan
    Liu, Wei
    Li, Famei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (24): : 2566 - 2570