Simultaneous determination of glimepiride and pioglitazone in human plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study

被引:19
|
作者
Ni, Xiao-Jia [1 ]
Wang, Zhan-Zhang [2 ]
Shang, De-Wei [1 ]
Zhang, Ming [1 ]
Hu, Jin-Qing [2 ]
Qiu, Chang [2 ]
Wen, Yu-Guan [1 ]
机构
[1] Guangzhou Med Univ, Inst Natl Drug Clin Trials, Clin Lab Phase 1, Guangzhou Brain Hosp, Guangzhou 510370, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Clin Pharm Guangzhou Brain Hosp, Guangzhou 510370, Guangdong, Peoples R China
关键词
LC-MS/MS; Glimepiride; Pioglitazone; Pharmacokinetic; INSULIN SENSITIVITY; HUMAN SERUM; LC-MS/MS; ALLOPURINOL; OXYPURINOL; METFORMIN; URINE;
D O I
10.1016/j.jchromb.2014.04.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rapid, sensitive, and selective liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) for the simultaneous estimation and pharmacokinetic investigation of glimepiride and pioglitazone in human plasma has been developed and fully validated. Glimepiride and pioglitazone, compounds which exert synergistic effects on blood glucose control, were investigated in human plasma using deuterium-labeled analogs as internal standards (IS). Liquid-liquid extraction was carried out on 0.2 mL of human plasma using ethyl acetate, and chromatographic separation was performed on an Agilent Eclipse plus C-18 column (4.6 mm x 100 mm, 3.5 mu m) using a mobile phase consisting of methanol-water-formic acid (95:5:0.1, v/v/v, plus 5 mM ammonium acetate) at a flow rate of 0.8 mL/min. To quantify glimepiride, pioglitazone and their IS, multiple reaction monitoring (MRM) transitions of m/z 491.2 -> 352.2, m/z 496.2 -> 357.2, m/z 357.2 -> 134.2 and m/z 361.2 -> 138.2 were performed in positive mode. The total run time was 3.0 min and the elution time was about 2.4 min. The method exhibited good separation of analytes, without interference from endogenous substances. The linear calibration curves were 0.2-250 ng/mL for glimepiride and 0.2-1250 ng/mL for pioglitazone; the lower limit of quantification (LLOQ) was 0.2 ng/mL for both analytes. Intra- and inter-day reproducibility was less than 10% for glimepiride and less than 5% for pioglitazone, with relative errors ranging from -8.00% to 2.80% at the three concentrations of analytes used for quality control (QC). The matrix effect was negligible and recoveries were similar for each analyte and its IS. Glimepiride and pioglitazone were found to be stable under the assay conditions and the method was successfully applied to the evaluation of pharmacokinetic studies of glimepiride and pioglitazone, following oral doses of 2 mg glimepiride tablets and 15 mg pioglitazone tablets to 16 healthy volunteers. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 252
页数:6
相关论文
共 50 条
  • [31] Determination of chamaechromone in rat plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Lou, Yan
    Hu, Haihong
    Liu, Yao
    Yu, Qinqin
    Li, Li
    Ping, Li
    Yu, Lushan
    Jiang, Huidi
    Zeng, Su
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1163 - 1169
  • [32] Determination of Raddeanin A in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study
    Luan, Xin
    Guan, Ying-Yun
    Wang, Chao
    Zhao, Mei
    Lu, Qin
    Tang, Ya-Bin
    Liu, Ya-Rong
    Yu, De-Hong
    Wang, Xiao-Lin
    Qi, Hong
    Fang, Chao
    Chen, Hong-Zhuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 923 : 43 - 47
  • [33] Quantitative determination of carfilzomib in mouse plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Min, Jee Sun
    Kim, Jiseon
    Kim, Jung Ho
    Kim, Doyun
    Zheng, Yu Fen
    Park, Ji Eun
    Lee, Wooin
    Bae, Soo Kyung
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 341 - 346
  • [34] Determination of motolimod concentration in rat plasma by liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Ji, Yu-Geun
    Shin, Yu-Mi
    Jeong, Jong-Woo
    Choi, Hae-In
    Lee, Seung-Won
    Lee, Jong-Hwa
    Lee, Kyeong-Ryoon
    Koo, Tae-Sung
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 179
  • [35] Determination of chrysotoxine in rat plasma by liquid chromatography-tandem mass spectrometry and its application to a rat pharmacokinetic study
    Fan, Jingjing
    Guan, Li
    Kou, Zeqi
    Feng, Feng
    Zhang, Yanbo
    Liu, Wenyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 57 - 62
  • [36] Determination of larotaxel and its metabolites in rat plasma by liquid chromatography-tandem mass spectrometry: Application for a pharmacokinetic study
    Liu, Zhenzhen
    Zhang, Lunhui
    Ju, Ping
    Hou, Pengyi
    Zhang, Yuanyuan
    Tang, Xing
    Bi, Kaishun
    Chen, Xiaohui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 132 - 138
  • [37] Determination of Tenacissoside A in rat plasma by liquid chromatography-tandem mass spectrometry method and its application to pharmacokinetic study
    Zhao, Luhua
    Xiang, Bingren
    Chen, Jing
    Tan, Xiying
    Wang, Dawei
    Chen, Daofeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1799 - 1804
  • [38] Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of lacidipine in human plasma and its application in a pharmacokinetic study
    Tang, Jing
    Zhu, Ronghua
    Zhao, Ruike
    Cheng, Gang
    Peng, Wenxing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) : 923 - 928
  • [39] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of scutellarin in human plasma: Application to a pharmacokinetic study
    Yulan, S
    Fang, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 1 - 5
  • [40] Liquid chromatography-tandem mass spectrometry method development and validation for the determination of erlotinib in human plasma and its application in pharmacokinetic study
    N. T. Ramarao
    S. Vidyadhara
    M. V. Basaveswara Rao
    R. L. C. Sasidhar
    R. Surendra Yadav
    Journal of Analytical Chemistry, 2015, 70 : 1488 - 1494