INSTRUMENTATION, MEASUREMENT AND PERFORMANCE OF THREE AIR QUALITY MEASUREMENT SYSTEMS FOR DAIRY BUILDINGS

被引:0
|
作者
Teye, F. K. [1 ]
Alkkiomaki, E. [2 ]
Simojoki, A. [3 ]
Pastell, M.
Hautala, M.
Ahokas, J.
机构
[1] Univ Helsinki, Fac Agr & Forestry, Dept Agrotechnol, FI-00014 Helsinki, Finland
[2] A Lab Ltd, Keuruu, Finland
[3] Univ Helsinki, Dept Appl Chem & Microbiol, Helsinki, Finland
关键词
Air-quality; Sensors; Wireless; Monitoring system; Dairy building; Methane; Ammonia; Carbon dioxide; AMMONIA EMISSIONS; POLLUTANTS; CATTLE;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Recent interest in global warming has led to the monitoring of operations such as dairy production that emit pollutants into the atmosphere. However, monitoring systems for indoor air quality in dairy buildings are still uncommon due to high costs involved in designing systems that can withstand high moisture, dust, corrosive gases, and varying temperatures. For studying the performance of measurement systems for dairy buildings, three different air quality measuring systems were built using both affordable and expensive sensors. The measurement systems were 1) a stationary system for longer period on-site measurements, 2) a wireless stationary system for off-site measurement, and 3) a mobile system for periodic air quality measurement. The instrumentation, measurement procedures, and performance of these systems are presented in this article. Spatial air quality survey showed high variation in microclimate conditions in the dairy building. Average deviation of sensors front the trite value in the different measurement systems was 1.1 degrees C for temperature, 3.6% for relative humidity, 450 ppm for carbon dioxide, 0.5 m/s for velocity, and 1 ppm for ammonia. Affordable sensors in the systems gave reasonably accurate readings when carefully calibrated. The single most practical location for installing air quality measurement systems was directly above the dairy cows in the center of the dairy building.
引用
收藏
页码:247 / 256
页数:10
相关论文
共 50 条
  • [1] Performance instrumentation and measurement for terascale systems
    Dongarra, J
    Malony, AD
    Moore, S
    Mucci, P
    Shende, S
    COMPUTATIONAL SCIENCE - ICCS 2003, PT IV, PROCEEDINGS, 2003, 2660 : 53 - 62
  • [2] Indoor air quality measurement in government buildings in Hksar
    Lau, KF
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 763 - 770
  • [3] Instrumentation and Measurement Systems
    Bader, Sebastian
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2023, 26 (07) : 28 - 33
  • [4] Air quality and emission measurement methodology at swine finishing buildings
    Heber, AJ
    Ni, JQ
    Haymore, BL
    Duggirala, RK
    Keener, KM
    TRANSACTIONS OF THE ASAE, 2001, 44 (06): : 1765 - 1778
  • [5] Air quality and emission measurement methodology at swine finishing buildings
    Heber, Albert J.
    Ni, Ji-Qin
    Haymore, Barry L.
    Duggirala, Ravi K.
    Keener, Kevin M.
    Transactions of the American Society of Agricultural Engineers, 2001, 44 (06): : 1765 - 1778
  • [6] MultiKron: Performance measurement instrumentation
    Mink, A
    IEEE INTERNATIONAL COMPUTER PERFORMANCE AND DEPENDABILITY SYMPOSIUM - IPDS'96, PROCEEDINGS, 1996, : 55 - 55
  • [7] Instrumentation and Measurement in Communication Systems
    Angrisani, Leopoldo
    Petri, Dario
    Yeary, Mark
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2015, 18 (02) : 4 - 10
  • [8] ZnO conductometric sensor for indoor air quality measurement inside buildings
    Gonzalez-Chavarri, J.
    Castro-Hurtado, I.
    Ayerdi, I.
    Castano, E.
    Mandayo, G. G.
    PROCEEDINGS OF THE 2015 10TH SPANISH CONFERENCE ON ELECTRON DEVICES (CDE), 2015, : 39 - +
  • [9] Measurement and evaluation of indoor air quality in naturally ventilated residential buildings
    Yin, Haiguo
    Liu, Chunxue
    Zhang, Leiming
    Li, Angui
    Ma, Zhenjun
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (10) : 1307 - 1323
  • [10] Measurement and simulation of indoor air quality and energy consumption in two Shanghai office buildings with variable air volume systems
    Pan, YQ
    Zhou, H
    Huang, ZH
    Zeng, Y
    Long, WD
    ENERGY AND BUILDINGS, 2003, 35 (09) : 877 - 891