ZnO conductometric sensor for indoor air quality measurement inside buildings

被引:0
|
作者
Gonzalez-Chavarri, J. [1 ,2 ,3 ]
Castro-Hurtado, I. [1 ,2 ,3 ]
Ayerdi, I. [1 ,2 ,3 ]
Castano, E. [1 ,2 ,3 ]
Mandayo, G. G. [1 ,2 ,3 ]
机构
[1] Univ Navarra, Ciet, P Mikeletegi 48, San Sebastian 20009, Spain
[2] Univ Navarra, Tecnun, San Sebastian 20009, Spain
[3] CIC microGUNE, Arrasate Mondragon 20500, Spain
关键词
zinc oxide; conductomentric sensor; benzene; formaldehyde; air quality;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this work is to develop a ZnO conductometric gas sensor to monitor two key pollutants in indoor environments: benzene and formaldehyde. Conductometric sensors are widely used for this purpose. The final aim of the sensor is to be integrated in an air quality measuring system connected to the HVAC (Heat Ventilation and Air Conditioning) system so that ventilation is activated according to the air quality within the building. As there is no EU common legislation about the target gases and detection limits, the authors have set them according to the recommendations of different agencies in Europe and the US.
引用
收藏
页码:39 / +
页数:4
相关论文
共 50 条
  • [1] Indoor air quality measurement in government buildings in Hksar
    Lau, KF
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 763 - 770
  • [2] Measurement and evaluation of indoor air quality in naturally ventilated residential buildings
    Yin, Haiguo
    Liu, Chunxue
    Zhang, Leiming
    Li, Angui
    Ma, Zhenjun
    [J]. INDOOR AND BUILT ENVIRONMENT, 2019, 28 (10) : 1307 - 1323
  • [3] A Novel Integrated Sensor System for Indoor Air Quality Measurement
    Masrie, Marianah
    Ahmad, Anuar
    Adnan, Ramli
    [J]. CSPA: 2009 5TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING AND ITS APPLICATIONS, PROCEEDINGS, 2009, : 406 - +
  • [4] INDOOR AIR QUALITY OF THE OFFICE BUILDINGS
    Senitkova, Ingrid
    Tomcik, Tomas
    [J]. CESB 10: CENTRAL EUROPE TOWARDS SUSTAINABLE BUILDING - FROM THEORY TO PRACTICE, 2010, : 517 - 520
  • [5] Indoor air quality - buildings design
    Senitkova, Ingrid Juhasova
    [J]. 8TH INTERNATIONAL SCIENTIFIC CONFERENCE BUILDING DEFECTS (BUILDING DEFECTS 2016), 2016, 93
  • [6] Indoor air quality for residential buildings
    Sherman, M
    [J]. ASHRAE JOURNAL, 1999, 41 (05) : 26 - 30
  • [7] Measurement of indoor air quality
    Endres, HE
    [J]. SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 467 - 474
  • [8] Microbiological indoor air quality in healthy buildings
    Sessa, R
    Di Pietro, M
    Schiavoni, G
    Santino, I
    Altieri, A
    Pinelli, S
    Del Piano, M
    [J]. MICROBIOLOGICA, 2002, 25 (01): : 51 - 56
  • [9] Mandating indoor air quality for public buildings
    Morawska, Lidia
    Allen, Joseph
    Bahnfleth, William
    Bennett, Belinda
    Bluyssen, Philomena M.
    Boerstra, Atze
    Buonanno, Giorgio
    Cao, Junji
    Dancer, Stephanie J.
    Floto, Andres
    Franchimon, Francesco
    Greenhalgh, Trish
    Haworth, Charles
    Hogeling, Jaap
    Isaxon, Christina
    Jimenez, Jose L.
    Kennedy, Amanda
    Kumar, Prashant
    Kurnitski, Jarek
    Li, Yuguo
    Loomans, Marcel
    Marks, Guy
    Marr, Linsey C.
    Mazzarella, Livio
    Melikov, Arsen Krikor
    Miller, Shelly L.
    Milton, Donald K.
    Monty, Jason
    Nielsen, Peter V.
    Noakes, Catherine
    Peccia, Jordan
    Prather, Kimberly A.
    Querol, Xavier
    Salthammer, Tunga
    Sekhar, Chandra
    Seppaenen, Olli
    Tanabe, Shin-ichi
    Tang, Julian W.
    Tellier, Raymond
    Tham, Kwok Wai
    Wargocki, Pawel
    Wierzbicka, Aneta
    Yao, Maosheng
    [J]. SCIENCE, 2024, 383 (6690) : 1418 - 1420
  • [10] Indoor air quality in urban office buildings
    Faria, T.
    Almeida-Silva, M.
    Dias, Ana
    Almeida, S. M.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2016, 19 (3-4) : 236 - 256