Diagnostic studies of a low-pressure inductively coupled plasma in argon using a double Langmuir probe

被引:28
|
作者
Sung, YI
Lim, HB
Houk, RS
机构
[1] Dankook Univ, Dept Chem, Seoul 140714, South Korea
[2] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
关键词
D O I
10.1039/b110219m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electron temperature and electron number density of a laboratory-built low-pressure inductively coupled plasma (LP-ICP) were measured using a double Langmuir probe. The probe was composed of two 0.5 mm diameter tungsten wires and a magnesia sleeve shielding the wires that could be linearly moved in the central channel of the plasma by a vacuum linear-motion feedthrough. The role of parameters was studied at a height of 25 mm above the load coil, which yielded an electron temperature of 3-6 eV and an electron number density of 2.5-5 x 10(13) cm(-3). Less dependence on operating factors was noticed at higher observation heights, and when water loaded on the low-pressure plasma was increased, the electron temperature and electron number density were reduced, unlike with an atmospheric ICP.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [31] Modeling of nonlocal electron kinetics in a low-pressure inductively coupled plasma
    Kolobov, VI
    Parker, GJ
    Hitchon, WNG
    PHYSICAL REVIEW E, 1996, 53 (01): : 1110 - 1124
  • [32] Low-pressure inductively coupled plasma as a new source of molecular beams
    Ryabov, V. L.
    Ezhov, V. F.
    Kartasheva, M. A.
    TECHNICAL PHYSICS LETTERS, 2006, 32 (11) : 969 - 971
  • [33] Langmuir probe diagnostics of a microfabricated inductively coupled plasma on a chip
    Minayeva, OB
    Hopwood, J
    JOURNAL OF APPLIED PHYSICS, 2003, 94 (05) : 2821 - 2828
  • [34] Simulation by COMSOL of Effects of Probe on Inductively Coupled Argon Plasma
    Shahbazian, A.
    Salem, M. K.
    Ghoranneviss, M.
    BRAZILIAN JOURNAL OF PHYSICS, 2021, 51 (03) : 351 - 360
  • [35] Simulation by COMSOL of Effects of Probe on Inductively Coupled Argon Plasma
    A. Shahbazian
    M. K. Salem
    M. Ghoranneviss
    Brazilian Journal of Physics, 2021, 51 : 351 - 360
  • [36] Langmuir probe potential measurements for reduced-pressure inductively coupled plasma mass spectrometry
    Yan, XM
    Huang, BL
    Tanaka, T
    Kawaguchi, H
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (07) : 697 - 701
  • [37] Langmuir Probe Diagnostics of Inductively Coupled Plasma Generated Using Flat Spiral Antenna
    Karar, Partha
    Kumar, Gourav
    Kar, Rajib
    Kewlani, Hitesh M.
    Patil, D. S.
    Dusane, Rajiv O.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (02) : 615 - 623
  • [38] Simulation of Low-Pressure Inductively Coupled Plasma with Displacement Potential and Gas Flow
    Shemakhin, A. Yu.
    PLASMA PHYSICS REPORTS, 2024, 50 (01) : 89 - 100
  • [39] Optical diagnostics of low-pressure inductively coupled plasma for nanocrystalline diamond growth
    Teii, K
    Ito, H
    Ishikawa, M
    Ito, M
    Hori, M
    Takeo, T
    Kato, T
    Goto, T
    INTERNATIONAL CONFERENCE ON PHENOMENA IN IONIZED GAS, VOL I, PROCEEDINGS, 1999, : 87 - 88
  • [40] LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA SOURCE FOR MASS-SPECTROMETRY
    EVANS, EH
    CARUSO, JA
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (03) : 427 - 431