Functional MRI of the rodent somatosensory pathway using multislice echo planar imaging

被引:86
|
作者
Keilholz, SD [1 ]
Silva, AC [1 ]
Raman, M [1 ]
Merkle, H [1 ]
Koretsky, AP [1 ]
机构
[1] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
关键词
fMRI; BOLD; somatosensory stimulation; multislice;
D O I
10.1002/mrm.20114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multislice EPI sequence was used to obtain functional MR images of the entire rat brain with BOLD contrast at 11.7 T. Ten to 11 slices covering the rat brain, with an in-plane resolution of 300 mum, provided enough sensitivity to detect activation in brain regions known to be involved in the somatosensory pathway during stimulation of the forelimbs. These regions were identified by warping a digitized rat brain atlas to each set of images. Data analysis was constrained to four major areas of the somatosensory pathway: primary and secondary somatosensory cortices, thalamus, and cerebellum. Incidence maps were generated. Electrical stimulation at 3 Hz led to significant activation in the primary sensory cortex in all rats. Activation in the secondary sensory cortex and cerebellum was observed in 70% of the studies, while thalamic activation was observed in 40%. The amplitude of activation was measured for each area, and average response time courses were calculated. Finally, the frequency dependence of the response to forepaw stimulation was measured in each of the activated areas. Optimal activation occurred in all areas at 3 Hz. These results demonstrate that whole-brain fMRI can be performed on rodents at 11.7 T to probe a well-defined neural network. Published 2004 Wiley-Liss, Inc.(dagger).
引用
收藏
页码:89 / 99
页数:11
相关论文
共 50 条
  • [21] Correction to: Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging
    Máté Kiss
    Petra Hermann
    Zoltán Vidnyánszky
    Viktor Gál
    Neuroradiology, 2018, 60 : 577 - 577
  • [22] Improving diffusion MRI using simultaneous multi-slice echo planar imaging
    Setsompop, K.
    Cohen-Adad, J.
    Gagoski, B. A.
    Raij, T.
    Yendiki, A.
    Keil, B.
    Wedeen, V. J.
    Wald, L. L.
    NEUROIMAGE, 2012, 63 (01) : 569 - 580
  • [23] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [24] Acoustic Noise Reduction of Echo Planar Imaging in Diffusion MRI
    Zhao, Junwei
    Lin, Zhenliang
    Zhou, Xiaodong
    Li, Guobin
    Luo, Jie
    ICBBE 2019: 2019 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING, 2019, : 33 - 38
  • [25] Prospective motion correction of 3D echo-planar imaging data for functional MRI using optical tracking
    Todd, Nick
    Josephs, Oliver
    Callaghan, Martina F.
    Lutti, Antoine
    Weiskopf, Nikolaus
    NEUROIMAGE, 2015, 113 : 1 - 12
  • [26] Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities
    Constable, RT
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 746 - 752
  • [27] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING WITH ECHO-PLANAR IMAGING
    KWONG, KK
    MAGNETIC RESONANCE QUARTERLY, 1995, 11 (01) : 1 - 20
  • [28] High temporal resolution functional MRI using parallel echo volumar imaging
    Rabrait, Cecile
    Ciuciu, Philippe
    Ribes, Alejandro
    Poupon, Cyril
    Le Roux, Patrick
    Dehaine-Lambertz, Ghislaine
    Le Bihan, D.
    Lethimonnier, F.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 744 - 753
  • [29] Single-shot echo planar time-resolved imaging for multi-echo functional MRI and distortion-free diffusion imaging
    Dong, Zijing
    Wald, Lawrence L.
    Polimeni, Jonathan R.
    Wang, Fuyixue
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 993 - 1013
  • [30] Simultaneous multislice acquisition using rosette trajectories (SMART): A new imaging method for functional MRI
    Noll, DC
    Peltier, SJ
    Boada, FE
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (05) : 709 - 716